X射线散射对面密度测量结果影响的数值模拟研究

上一篇

下一篇

朱鹏飞, 叶雁, 李作友, 阳庆国, 祁双喜, 钱伟新, 程晋明. 2015: X射线散射对面密度测量结果影响的数值模拟研究, 强激光与粒子束, 27(6): 212-216. doi: 10.11884/HPLPB201527.064001
引用本文: 朱鹏飞, 叶雁, 李作友, 阳庆国, 祁双喜, 钱伟新, 程晋明. 2015: X射线散射对面密度测量结果影响的数值模拟研究, 强激光与粒子束, 27(6): 212-216. doi: 10.11884/HPLPB201527.064001
Zhu Pengfei, Ye Yan, Li Zuoyou, Yang Qingguo, Qi Shuangxi, Qian Weixin, Chen Jinming. 2015: Numerical simulation study of effects of X-ray scattering on areal density measurement results, High Power Lase and Particle Beams, 27(6): 212-216. doi: 10.11884/HPLPB201527.064001
Citation: Zhu Pengfei, Ye Yan, Li Zuoyou, Yang Qingguo, Qi Shuangxi, Qian Weixin, Chen Jinming. 2015: Numerical simulation study of effects of X-ray scattering on areal density measurement results, High Power Lase and Particle Beams, 27(6): 212-216. doi: 10.11884/HPLPB201527.064001

X射线散射对面密度测量结果影响的数值模拟研究

Numerical simulation study of effects of X-ray scattering on areal density measurement results

  • 摘要: 定性分析了X射线散射对面密度测量结果的影响,给出了面密度测量结果偏差的评估表达式.利用蒙特卡罗方法数值模拟了不同照相布局、不同光源能量和不同材料类型情形下X射线散射对测量结果的影响.模拟结果表明:在无防护窗情形下,被测物自身散射将导致测量结果偏小;在有防护窗情形下,前窗散射对测量结果的影响不大,后窗散射对测量结果的影响与接收介质离被测物的距离有关,具体表现为距离越小影响越大;在一定光子能量范围内,光源能量越低散射导致的测量偏差越大;被测物的原子序数和密度越大,散射导致的测量偏差越大.
  • 加载中
  • 加载中
计量
  • 文章访问数:  255
  • HTML全文浏览数:  57
  • PDF下载数:  21
  • 施引文献:  0
出版历程
  • 刊出日期:  2015-06-30

X射线散射对面密度测量结果影响的数值模拟研究

  • 中国工程物理研究院流体物理研究所,四川绵阳,621900

摘要: 定性分析了X射线散射对面密度测量结果的影响,给出了面密度测量结果偏差的评估表达式.利用蒙特卡罗方法数值模拟了不同照相布局、不同光源能量和不同材料类型情形下X射线散射对测量结果的影响.模拟结果表明:在无防护窗情形下,被测物自身散射将导致测量结果偏小;在有防护窗情形下,前窗散射对测量结果的影响不大,后窗散射对测量结果的影响与接收介质离被测物的距离有关,具体表现为距离越小影响越大;在一定光子能量范围内,光源能量越低散射导致的测量偏差越大;被测物的原子序数和密度越大,散射导致的测量偏差越大.