电晕均压多间隙串联气体开关特性实验

上一篇

下一篇

姜晓峰, 丛培天, 孙凤举, 孙铁平, 梁天学, 魏浩, 王志国. 2016: 电晕均压多间隙串联气体开关特性实验, 强激光与粒子束, 28(7): 075009. doi: 10.11884/HPLPB201628.075009
引用本文: 姜晓峰, 丛培天, 孙凤举, 孙铁平, 梁天学, 魏浩, 王志国. 2016: 电晕均压多间隙串联气体开关特性实验, 强激光与粒子束, 28(7): 075009. doi: 10.11884/HPLPB201628.075009
Jiang Xiaofeng, Cong Peitian, Sun Fengju, Sun Tieping, Liang Tianxue, Wei Hao, Wang Zhiguo. 2016: Breakdown characteristics of a multi-gap gas switch with corona discharge for voltage balance, High Power Lase and Particle Beams, 28(7): 075009. doi: 10.11884/HPLPB201628.075009
Citation: Jiang Xiaofeng, Cong Peitian, Sun Fengju, Sun Tieping, Liang Tianxue, Wei Hao, Wang Zhiguo. 2016: Breakdown characteristics of a multi-gap gas switch with corona discharge for voltage balance, High Power Lase and Particle Beams, 28(7): 075009. doi: 10.11884/HPLPB201628.075009

电晕均压多间隙串联气体开关特性实验

Breakdown characteristics of a multi-gap gas switch with corona discharge for voltage balance

  • 摘要: 研制了一种电晕放电均压的小型多间隙串联气体开关,分析了电晕放电在开关工作过程中的作用,开展了开关自击穿特性、电晕放电伏安特性、针尖烧蚀以及开关寿命测试等特性实验。结果表明:老练后开关自击穿电压标准偏差小于3.5%,电晕均压效果明显;随着放电次数增加,电晕针尖逐渐钝化,触发性能变化不大;开关电晕放电电流随耐受电压升高增大,增长趋势逐渐变快;开关充400 kPa 干燥空气,±100 kV 工作电压下开关放电50000次以上,触发性能稳定,触发击穿时延抖动约4.3 ns,自放电概率低于1×10-4。
  • 加载中
  • 加载中
计量
  • 文章访问数:  376
  • HTML全文浏览数:  182
  • PDF下载数:  21
  • 施引文献:  0
出版历程
  • 刊出日期:  2016-07-30

电晕均压多间隙串联气体开关特性实验

  • 西北核技术研究所,强脉冲辐射环境模拟与效应国家重点实验室,西安 710024

摘要: 研制了一种电晕放电均压的小型多间隙串联气体开关,分析了电晕放电在开关工作过程中的作用,开展了开关自击穿特性、电晕放电伏安特性、针尖烧蚀以及开关寿命测试等特性实验。结果表明:老练后开关自击穿电压标准偏差小于3.5%,电晕均压效果明显;随着放电次数增加,电晕针尖逐渐钝化,触发性能变化不大;开关电晕放电电流随耐受电压升高增大,增长趋势逐渐变快;开关充400 kPa 干燥空气,±100 kV 工作电压下开关放电50000次以上,触发性能稳定,触发击穿时延抖动约4.3 ns,自放电概率低于1×10-4。