  • 摘要: 设计了基于Sagnac环形镜的哑铃型结构全光纤掺镱激光器,使用976 nm多模激光二极管泵浦,通过调节偏振控制器获得了稳定的多波长线偏振激光输出.泵浦功率为20.4W时,最高输出功率达到5.13W,功率波动不大于0.02 W,激光器输出多波长激光线偏振度约为14.19 dB,多波长输出功率平坦度优于3 dB.
  • 加载中
  • 加载中
计量
  • 文章访问数:  259
  • HTML全文浏览数:  139
  • PDF下载数:  7
  • 施引文献:  0
出版历程
  • 刊出日期:  2017-04-30

基于Sagnac环形镜的高功率多波长线偏振掺镱光纤激光器

  • 国防科学技术大学光电科学与工程学院,长沙,410073

摘要: 设计了基于Sagnac环形镜的哑铃型结构全光纤掺镱激光器,使用976 nm多模激光二极管泵浦,通过调节偏振控制器获得了稳定的多波长线偏振激光输出.泵浦功率为20.4W时,最高输出功率达到5.13W,功率波动不大于0.02 W,激光器输出多波长激光线偏振度约为14.19 dB,多波长输出功率平坦度优于3 dB.