基于触发检测的晶闸管控制电抗器 动态响应时间评估方法

上一篇

下一篇

吴亚楠, 茆华风, 沈显顺, 李俊, 卢晶, 茆智伟. 2019: 基于触发检测的晶闸管控制电抗器 动态响应时间评估方法, 强激光与粒子束, 31(5): 68-72. doi: 10.11884/HPLPB201931.180362
引用本文: 吴亚楠, 茆华风, 沈显顺, 李俊, 卢晶, 茆智伟. 2019: 基于触发检测的晶闸管控制电抗器 动态响应时间评估方法, 强激光与粒子束, 31(5): 68-72. doi: 10.11884/HPLPB201931.180362
Wu Ya'nan, Mao Huafeng, Shen Xianshun, Li Jun, Lu Jing, Mao Zhiwei. 2019: Assessment method of thyristor controlled reactor dynamic response time based on trigger detection, High Power Lase and Particle Beams, 31(5): 68-72. doi: 10.11884/HPLPB201931.180362
Citation: Wu Ya'nan, Mao Huafeng, Shen Xianshun, Li Jun, Lu Jing, Mao Zhiwei. 2019: Assessment method of thyristor controlled reactor dynamic response time based on trigger detection, High Power Lase and Particle Beams, 31(5): 68-72. doi: 10.11884/HPLPB201931.180362

基于触发检测的晶闸管控制电抗器 动态响应时间评估方法

Assessment method of thyristor controlled reactor dynamic response time based on trigger detection

  • 摘要: 针对传统响应时间检测方法存在基准时刻不统一、依赖间接测量量的问题,提出了一种基于实际触发角检测的晶闸管控制电抗器(TCR)动态响应时间评估方法.依据过零切除固定电容器组产生阶跃参考量统一基准时刻,通过TCR实际触发角与下限值的比较确定响应时刻,进而直接评估响应时间.实验结果表明,该方法可有效应用于大容量TCR型无功补偿装置动态响应性能分析、评价.
  • 加载中
  • 加载中
计量
  • 文章访问数:  77
  • HTML全文浏览数:  59
  • PDF下载数:  2
  • 施引文献:  0
出版历程
  • 刊出日期:  2019-01-01

基于触发检测的晶闸管控制电抗器 动态响应时间评估方法

  • 中国科学院 等离子体物理研究所,合肥,230031
  • 中国科学院 等离子体物理研究所,合肥 230031;中国科学技术大学 研究生院科学岛分院,合肥 230026

摘要: 针对传统响应时间检测方法存在基准时刻不统一、依赖间接测量量的问题,提出了一种基于实际触发角检测的晶闸管控制电抗器(TCR)动态响应时间评估方法.依据过零切除固定电容器组产生阶跃参考量统一基准时刻,通过TCR实际触发角与下限值的比较确定响应时刻,进而直接评估响应时间.实验结果表明,该方法可有效应用于大容量TCR型无功补偿装置动态响应性能分析、评价.

English Abstract

参考文献 (0)

目录

/

返回文章
返回