高能同步辐射光源增强器同步光引出系统的研制

,  ,  ,  ,  ,  , 

上一篇

下一篇

张洪琦, 王博锋, 赵金玉, 刘佳明, 祝德充, 王聪, 周健勇. 高能同步辐射光源增强器同步光引出系统的研制[J]. 真空科学与技术学报, 2026, 46(9): 876-880. doi: 10.13922/j.cnki.cjvst.202511012
引用本文: 张洪琦, 王博锋, 赵金玉, 刘佳明, 祝德充, 王聪, 周健勇. 高能同步辐射光源增强器同步光引出系统的研制[J]. 真空科学与技术学报, 2026, 46(9): 876-880. doi: 10.13922/j.cnki.cjvst.202511012
Hongqi ZHANG, Bofeng WANG, Jinyu ZHAO, Jiaming LIU, Dechong ZHU, Cong WANG, Jianyong ZHOU. Development of the Synchrotron Radiation Extraction System for the High Energy Photon Source (HEPS) Booster[J]. zkkxyjsxb, 2026, 46(9): 876-880. doi: 10.13922/j.cnki.cjvst.202511012
Citation: Hongqi ZHANG, Bofeng WANG, Jinyu ZHAO, Jiaming LIU, Dechong ZHU, Cong WANG, Jianyong ZHOU. Development of the Synchrotron Radiation Extraction System for the High Energy Photon Source (HEPS) Booster[J]. zkkxyjsxb, 2026, 46(9): 876-880. doi: 10.13922/j.cnki.cjvst.202511012

高能同步辐射光源增强器同步光引出系统的研制

    通讯作者: E-mail: 1372850788@qq.com; 
  • 中图分类号: TL503.4

Development of the Synchrotron Radiation Extraction System for the High Energy Photon Source (HEPS) Booster

    Corresponding author: Hongqi ZHANG, 1372850788@qq.com ; 
  • MSC: TL503.4

  • 摘要: 为计算高能同步辐射光源(HEPS)增强器高能束流的发射度和能散等参数,需通过引出系统将束线内的同步辐射光引出。本文研究了同步光引出系统各部件组成、各部件的加工制造及检测技术,研制了引出系统的核心部件高精度反光镜。镜面钎焊前表面粗糙度为0.53~0.94 nm,面型精度27.9~63 nm,钎焊后表面粗糙度为0.625~0.977 nm,面型精度58~95 nm。引出系统真空腔体经超高真空烘烤后,内部极限真空度达9.1×10−8 Pa,真空漏率8.7×10−12 Pa·m3/s,且实现超高真空贮存。
  • 加载中
  • 图 1  引出系统组成

    Figure 1.  Composition of extraction system

    图 2  引出系统原理

    Figure 2.  Principle of extraction system

    图 3  反光镜组件结构图

    Figure 3.  Reflector assembly structure

    图 4  反光镜组件原理图

    Figure 4.  Reflector assembly schematic

    图 5  真空钎焊温度曲线

    Figure 5.  Vacuum brazing temperature profile

    图 6  表面粗糙度测试

    Figure 6.  Surface roughness testing

    图 7  面型精度测试

    Figure 7.  Figure accuracy testing

    图 8  表面粗糙度测试(钎焊后)

    Figure 8.  Surface roughness testing (Brazed)

    图 9  面型精度测试(钎焊后)

    Figure 9.  Figure accuracy testing (Brazed)

    图 10  超高真空烘烤排气系统原理图

    Figure 10.  Schematic diagram of ultra-high vacuum baking and outgassing system

    图 11  烘烤除气安装实物图

    Figure 11.  The baking exhaust installation

    图 12  同步光引出系统

    Figure 12.  Synchrotron light extraction system

    表 1  反光镜设计参数

    Table 1.  Design parameters of the mirror

    序号 名称 数值
    1 反光镜尺寸 35 mm×20 mm×8.5 mm
    2 反光镜表面粗糙度 1 nm
    3 反光镜面型精度 <λ/10(λ=632.8 nm)
    下载: 导出CSV
  • [1] 李晓东, 袁清习, 徐伟, 等. 第四代高能同步辐射光源 HEPS 及高压相关线站建设[J]. 高压物理学报, 2020, 34(5): 13 (in Chinese) doi: 10.11858/gywlxb.20200554 Li X D, Yuan Q X, Xu W, et al. Introduction of fourth-generation high energy photon source HEPS and the beamlines for high-pressure research.[J]. Chinese Journal of High Pressure Physics, 2020, 34(5): 13 doi: 10.11858/gywlxb.20200554
    [2] 姜晓明, 王九庆, 秦庆, 等. 中国高能同步辐射光源及其验证装置工程[J]. 中国科学: 物理学、力学、天文学, 2014, 44(10): 20 (in Chinese) Jiang X M, Wang J Q, Qin Q, et al. Chinese high energy photon source and the test facility[J]. Scientia Sinica: Physica, Mechanica & Astronomica, 2014, 44(10): 20
    [3] Bergstrom J, Vogt J. The optical diagnostic beamline at the canadian light source[J]. Nuclear Instruments & Methods in Physics Research Section A-accelerators Spectrometers Detectors and Associated Equipment, 2006, 562(1): 495−512 doi: 10.1016/j.nima.2006.02.200
    [4] 祝德充, 随艳峰, 岳军会, 等. 高能光源增强器束流横向尺寸测量系统设计[J]. 强激光与粒子束, 2021, 33(4): 81−85 (in Chinese) doi: 10.11884/HPLPB202133.200268 Zhu D C, Sui Y F, Yue J H, et al. Design of high energy photon source booster beam size monitor[J]. High Power Laser and Particle Beams, 2021, 33(4): 81−85 doi: 10.11884/HPLPB202133.200268
    [5] Duan Z, Chen J H, Shi H, et al. Using a pre-kicker to ensure safe extractions from the HEPS storage ring[J]. Nuclear Science and Techniques, 2021, 32(12): 26−36 doi: 10.1007/s41365-021-00974-z
    [6] 温利, 姚多舜, 周泗忠, 等. BEPC 储存环同步光束流测量光学系统[J]. 光学精密工程, 2002, 10(5): 513−517 (in Chinese) doi: 10.3321/j.issn:1004-924X.2002.05.017 Wen L, Yao D S, Zhou S Z, et al. Design of the synchrotron light measurement system for BFPC storage ring[J]. Optics and Precision Engineering, 2002, 10(5): 513−517 doi: 10.3321/j.issn:1004-924X.2002.05.017
    [7] Cheng W, Fernandes H, Hseuh H, et al. Design of visible diagnostic beamline for NSLS2 storage ring[J]. Presented at the 2011 Particle Accelerator Conference, 2011: 453−455
    [8] Cheng W. Synchrotron light monitor system for NSLS-II[J]. Proceedings of BIW10, 2014, 478−482
    [9] E F Daly, A S Fisher. Institute of electric and electronic engineer. mechanical design of the HER synchrotron light monitor primary mirror for the PEP-II B-Factory[C]//Particle Accelerator Conference, 1997. Proceedings of the 1997, 2(1998): 2014−2016
    [10] Zhang W, Zhu D C, He J, et al. Experimental study of beam parameters in the HEPS booster using visible light imaging monitors[J]. IOP Publishing Ltd, 2026, 21(04): T04003
    [11] 张帅, 王小霞, 罗积润, 等. 烧结处理对微波真空电子器件电镀镍层性能的影响[J]. 电镀与涂饰, 2020, 39(19): 4 (in Chinese) Zhang S, Wang X X, Luo J R, et al. Effect of sintering on properties of nickel coating electroplated on surface of microwave vacuum electronic device[J]. Electroplating & Finishing, 2020, 39(19): 4
    [12] 蒋斌, 邢丕峰, 魏成富, 等. 高温下镜面纯 Fe 的表面质量研究[J]. 强激光与粒子束, 2014, 26(11): 99−104 (in Chinese) Jiang B, Xing P F, Wei C F, et al. Surface quality of mirror pure Fe at high temperature[J]. High Power Laser and Particle Beams, 2014, 26(11): 99−104
  • 加载中
图( 12) 表( 1)
计量
  • 文章访问数:  79
  • HTML全文浏览数:  79
  • PDF下载数:  0
  • 施引文献:  0
出版历程
  • 收稿日期:  2025-11-28
  • 刊出日期:  2026-09-30

高能同步辐射光源增强器同步光引出系统的研制

    通讯作者: E-mail: 1372850788@qq.com; 
  • 1. 中国科学院空天信息创新研究院 北京 101400
  • 2. 中国科学院高能物理研究所 北京 100049

摘要: 为计算高能同步辐射光源(HEPS)增强器高能束流的发射度和能散等参数,需通过引出系统将束线内的同步辐射光引出。本文研究了同步光引出系统各部件组成、各部件的加工制造及检测技术,研制了引出系统的核心部件高精度反光镜。镜面钎焊前表面粗糙度为0.53~0.94 nm,面型精度27.9~63 nm,钎焊后表面粗糙度为0.625~0.977 nm,面型精度58~95 nm。引出系统真空腔体经超高真空烘烤后,内部极限真空度达9.1×10−8 Pa,真空漏率8.7×10−12 Pa·m3/s,且实现超高真空贮存。

English Abstract

  • 高能同步辐射光源(High Energy Photon Source,HEPS)作为中国“十三五”规划确定的重大科技基础设施之一,是中国基础科学实现突破性创新研究的重要平台,在中国资源、环境、卫生等多方面提供强有力的基础科学支撑[1]。

    直线加速器注入的束流经增强器提升至储存环所需能量,为其提供高质量电子束[2-3]。由加速器注入的束流经过升能−引出−降能过程,完成一个周期工作[4-7]。为了对束流升能状态进行监测,使用增强器同步光引出系统内置的高精度反射镜将同步辐射光中的可见光引出并得到束斑的横截面尺寸,进而计算出束流发射度和能散等参数。目前超高真空引出装置反光镜主要有全引出反光镜、半引出反光镜、狭缝反光镜及中间薄两侧厚反光镜等样式,其主要目的是实现不同类型可见光的引出。反射表面通常由铜进行镜面抛光工艺制备,也有使用金刚石和铍材质制成,其具有非常可观的热导率,保证镜面及时散热 [8-9]。本文研制了以无氧铜为基底、高精度抛光金属镀镍层的反射镜引光装置。镍具有高硬度、耐腐蚀等特点,可在一定程度上提高引出光精度及反光镜的使用寿命。本文针对高能光源增强器同步光引出系统的研制需求,设计并制造了同步光引出系统,为研究增强器同步光测试系统提供支撑。

    • 引出系统主要由反光镜组件、光阑组件、主腔体、法兰和支撑调节机构组成,如图1所示。

      引出系统的主要功能是将同步辐射光中的可见光通过反射镜反射引出,其原理如图2所示。高能电子束流在磁场作用下做圆周运动,穿过引出系统的圆形截面孔。同步辐射光沿束流切线方向射出,通过光阑孔调整尺寸后,其中的可见光由反光镜反射,经石英窗引出至真空外的同步光成像系统,由成像系统分析束流的尺寸、能散等参数。

    • 反光镜组件作为引出系统的核心部件,是以无氧铜为基底、高精度抛光金属镍为镀层的主反射镜引光装置。其主要由反光镜、底座、水冷管及密封法兰组成,部件组成及设计原理如图3和图4所示。冷却水通过入水管进行入无氧铜底座,流经反光镜通过出水管排出,实现对反光镜的冷却。

      反光镜的表面要求如表1所示。

      反光镜主体材料选择无氧铜,在35×20×8.4 mm的无氧铜块上镀0.2 mm的镍层,使用超高精度单点金刚石加工机床进行磨抛,加工至8.5 mm。该机床加工元件的表面粗糙度优于5 nm,最大加工口径可达400 mm。使反光镜表面粗糙度优于1 nm,面型精度达到λ/10(λ=632.8 nm)。

      在可见光引出的过程中,由于X射线会沉积在镜内,热沉积会造成镜面形变、降低测量精度,需通过水冷的方式散热[10]。为了保证铜镜和底座之间热交换充分,通过真空钎焊工艺,采用满填钎料的方式,保证镜体与母材之间充分接触,以提高反光镜组件的换热效率。

      金属镀镍层在经过850℃的高温后,表面晶粒通过再结晶长大,由块状向颗粒状转变,表面更致密。同时镀层经高温后其表面粗糙度增大,这种变化与晶粒的结晶长大有关[11-12]。因此为了保护高精度光学表面,选择低熔点的银铜铟(AgCuIn)钎料对反光镜进行钎焊,其液相线温度为730℃,固相线温度为685℃。

      焊接采用立式程控真空炉,可保证反光镜组件的洁净度,焊接温度曲线如图5所示。

    • 使用粗糙度轮廓仪和激光干涉仪对反光镜高精度表面粗糙度与面型精度进行测试,如图6和图7所示。加工后反光镜表面粗糙度为0.53~0.94 nm,面型精度为27.9~63 nm,均优于表1的设计指标,满足同步光反射的高精度要求。

      通过真空钎焊后,再次对反光镜表面进行粗糙度和面型精度的测量,测试结果如图8和图9所示。反光镜表面粗糙度为0.625~0.977 nm,粗糙度略有上升,但满足表1 的设计指标。钎焊后的面型精度58~95 nm。相较于未钎焊的反光镜面型精度下降比较明显,部分镜面的面型精度已经大于λ/10(λ=632.8 nm),已不符合设计指标要求。通过对比钎焊前后的高精度镜面的粗糙度和面型精度测试结果可知,在经历高温后,反光镜表面的质量下降,主要体现在粗糙度略微升高,面型质量明显降低。

    • 高能束流通过同步光引出系统进行引出,因此引出系统内部需达到超高真空。根据使用需求,其极限真空度需达到1×10−7 Pa,真空漏率优于1×10−11 Pa·m3/s。

      超高真空烘烤排气设备真空系统原理图如图10所示。烘烤排气台真空系统由加热炉体(钟罩)、内真空系统、外真空系统、真空计和阀门等组成。该设备配备了电阻规和电离规作为真空测量设备安装于靠近炉体内部的真空管道处(图中7、8所示)尽量靠近被测部件位置。通过真空法兰和波纹管将引出系统的抽气口与真空系统连接(如图11所示)后,进行烘烤除气工艺。烘烤除气工艺的烘烤总时长为38 h,其中升温约6 h,升温速率为30℃/h,保温24 h,保温温度为200℃,再以30℃/h的降温速率降温3 h后自然降温5h至室温。烘烤除气前真空漏率为8.7×10−12 Pa·m3/s。在烘烤除气工艺完成后,引出系统内部极限真空度达到9.1×10−8 Pa,经冷焊封离,腔体内部保持超高真空状态,实现超高真空贮存。

      将真空腔体与调节支撑组件安装后,完成引出光系统整体的加工制造,如图12所示。

    • (1) 完成了高能同步辐射光源同步光引出系统的研制,使用超高精度单点金刚石加工机床完成了其核心部件——高精度反光镜表面的制备;

      (2) 通过高温钎焊工艺,实现反光镜的高热导率,提升部件的换热效率。

      (3) 实现引出系统高精度反光镜的加工制造及高精度检测,钎焊前镜面粗糙度0.53~0.94 nm,面型精度27.9~63 nm,钎焊后镜面粗糙度为0.625~0.977 nm,面型精度为58~95 nm,钎焊后反光镜表面质量有所下降;

      (4) 使用超高真空烘烤排气设备,使引出系统内部极限真空达到9.1×10−8 Pa,漏率8.7×10−12 Pa·m3/s,通过冷焊封离实现超高真空贮存;

      (5) 本研制的同步光引出系统已完成整机装配和性能验证,可应用于 HEPS 增强器束流参数的实时监测,为 HEPS 的稳定运行提供重要技术保障。

    参考文献 (12)

目录

/

返回文章
返回