分段保护超导螺线管磁体失超过程的过电压

上一篇

下一篇

郭兴龙, 徐风雨, 王莉, 潘衡, 吴红, 刘孝坤, M. A. Green. 2010: 分段保护超导螺线管磁体失超过程的过电压, 强激光与粒子束, 22(5): 1112-1116. doi: 10.3788/HPLPB20102205.1112
引用本文: 郭兴龙, 徐风雨, 王莉, 潘衡, 吴红, 刘孝坤, M. A. Green. 2010: 分段保护超导螺线管磁体失超过程的过电压, 强激光与粒子束, 22(5): 1112-1116. doi: 10.3788/HPLPB20102205.1112
Guo Xinglong, Xu Fengyu, Wang Li, Pan Heng, Wu Hong, Liu Xiaokun, M. A. Green. 2010: Over voltage for multi-sectioned superconducting solenoid magnet during quench process, High Power Lase and Particle Beams, 22(5): 1112-1116. doi: 10.3788/HPLPB20102205.1112
Citation: Guo Xinglong, Xu Fengyu, Wang Li, Pan Heng, Wu Hong, Liu Xiaokun, M. A. Green. 2010: Over voltage for multi-sectioned superconducting solenoid magnet during quench process, High Power Lase and Particle Beams, 22(5): 1112-1116. doi: 10.3788/HPLPB20102205.1112

分段保护超导螺线管磁体失超过程的过电压

Over voltage for multi-sectioned superconducting solenoid magnet during quench process

  • 摘要: 超导磁体失超过程的过电压准确分析是失超保护系统设计的基础.对于分段保护的超导螺线管磁体,在传统椭球形正常区失超传播模型的基础上,将3维温度计算结果映射到1维导线方向上,确定沿导线的温度分布,进而计算出各匝电阻.将线圈看作以匝为单位的电阻和电感组成的电路,计算出沿导线的电阻电压、电感电压以及合电压瞬态分布,较准确地估计了失超过程中最大对地电压、层间电压和匝间电压.利用该方法对某分段保护的螺线管磁体进行了计算,获得了失超过程中磁体内部过电压;发现磁体内部的电压分布由方向相反的电感电压和电阻电压共同决定;以单段正常区电阻电压作为该磁体对地电压过于保守.
  • 加载中
  • 加载中
计量
  • 文章访问数:  570
  • HTML全文浏览数:  68
  • PDF下载数:  52
  • 施引文献:  0
出版历程
  • 刊出日期:  2010-05-30

分段保护超导螺线管磁体失超过程的过电压

  • 哈尔滨工业大学,低温与超导技术研究所,哈尔滨,150001
  • 劳伦兹伯克利国家实验室,加利福尼亚,94720,美国

摘要: 超导磁体失超过程的过电压准确分析是失超保护系统设计的基础.对于分段保护的超导螺线管磁体,在传统椭球形正常区失超传播模型的基础上,将3维温度计算结果映射到1维导线方向上,确定沿导线的温度分布,进而计算出各匝电阻.将线圈看作以匝为单位的电阻和电感组成的电路,计算出沿导线的电阻电压、电感电压以及合电压瞬态分布,较准确地估计了失超过程中最大对地电压、层间电压和匝间电压.利用该方法对某分段保护的螺线管磁体进行了计算,获得了失超过程中磁体内部过电压;发现磁体内部的电压分布由方向相反的电感电压和电阻电压共同决定;以单段正常区电阻电压作为该磁体对地电压过于保守.