密封容器中钚材料同位素丰度和年龄的测量

上一篇

下一篇

刘素萍, 龚建, 郝樊华, 伍怀龙, 胡广春, 向永春, 迮仁德, 章建华. 2005: 密封容器中钚材料同位素丰度和年龄的测量, 原子核物理评论, 22(1): 127-130,134. doi: 10.3969/j.issn.1007-4627.2005.01.039
引用本文: 刘素萍, 龚建, 郝樊华, 伍怀龙, 胡广春, 向永春, 迮仁德, 章建华. 2005: 密封容器中钚材料同位素丰度和年龄的测量, 原子核物理评论, 22(1): 127-130,134. doi: 10.3969/j.issn.1007-4627.2005.01.039
LIU Su-ping, GONG Jian, HAO Fan-hua, WU Huai-long, HU Guang-chun, XIANG Yong-chun, ZHE Ren-de, ZHANG Jian-hua. 2005: Measurement of Isotopic Abundance and Age of the Plutonium Material in a Sealed Container, Nuclear Physics Review, 22(1): 127-130,134. doi: 10.3969/j.issn.1007-4627.2005.01.039
Citation: LIU Su-ping, GONG Jian, HAO Fan-hua, WU Huai-long, HU Guang-chun, XIANG Yong-chun, ZHE Ren-de, ZHANG Jian-hua. 2005: Measurement of Isotopic Abundance and Age of the Plutonium Material in a Sealed Container, Nuclear Physics Review, 22(1): 127-130,134. doi: 10.3969/j.issn.1007-4627.2005.01.039

密封容器中钚材料同位素丰度和年龄的测量

Measurement of Isotopic Abundance and Age of the Plutonium Material in a Sealed Container

  • 摘要: 根据相对效率法的原理, 利用PC/FRAM分析软件, 开展了用高分辨γ谱仪测量密封容器中钚材料的同位素丰度和年龄的实验研究.研究结果表明, 同位素丰度和年龄的分析精度随能谱测量精度的提高而提高, 如果能谱的测量精度不够, 通过PC/FRAM分析得出的钚材料的同位素丰度和年龄有偏低的可能.因此, 在能谱测量过程中, 建议通过监测某个特征峰的峰面积计数来判定239Pu丰度和年龄的测量精度是否已满足测量要求.
  • 加载中
  • 加载中
计量
  • 文章访问数:  430
  • HTML全文浏览数:  140
  • PDF下载数:  10
  • 施引文献:  0
出版历程
  • 刊出日期:  2005-03-20

密封容器中钚材料同位素丰度和年龄的测量

  • 中国工程物理研究院核物理与化学研究所,四川,绵阳,621900

摘要: 根据相对效率法的原理, 利用PC/FRAM分析软件, 开展了用高分辨γ谱仪测量密封容器中钚材料的同位素丰度和年龄的实验研究.研究结果表明, 同位素丰度和年龄的分析精度随能谱测量精度的提高而提高, 如果能谱的测量精度不够, 通过PC/FRAM分析得出的钚材料的同位素丰度和年龄有偏低的可能.因此, 在能谱测量过程中, 建议通过监测某个特征峰的峰面积计数来判定239Pu丰度和年龄的测量精度是否已满足测量要求.