基于拉曼热测量技术的铜基复合物法兰GaN基晶体管的热阻分析

    作者简介: lkqm22@163.com .
    通讯作者: E-mail: huarui.sun@hit.edu.cn
  • 中图分类号: 85.30.Tv, 65.40.-b, 62.23.Pq, 78.30.-j

Raman thermometry based thermal resistance analysis of GaN high electron mobility transistors with copper-based composite flanges

    Corresponding author: E-mail: huarui.sun@hit.edu.cn
  • MSC: 85.30.Tv, 65.40.-b, 62.23.Pq, 78.30.-j

  • 摘要: 采用拉曼热测量技术结合有限元热仿真模型, 分析比较新型铜/石墨复合物法兰封装与传统铜钼法兰封装的GaN器件的结温与热阻, 发现前者的整体热阻比铜钼法兰器件的整体热阻低18.7%, 器件内部各层材料的温度分布显示铜/石墨复合物法兰在器件中的热阻占比相比铜钼法兰在器件中的热阻占比低13%, 这证明使用高热导率铜/石墨复合物法兰封装提高GaN器件热扩散性能的有效性. 通过对两种GaN器件热阻占比的测量与分析, 发现除了封装法兰以外, 热阻占比最高的是GaN外延与衬底材料之间的界面热阻, 降低界面热阻是进一步提高器件热性能的关键. 同时, 详细阐述了使用拉曼光热技术测量GaN器件结温和热阻的原理和过程, 展示了拉曼光热技术作为一种GaN器件热特性表征方法的有效性.
  • 加载中
  • 图 1  (a)被测GaN高电子迁移率场效应管器件结构以及拉曼热测量的示意图; (b)被测器件在50 ℃和300 ℃的拉曼特征峰: 包括GaN外延的E2(high)和A1(LO)峰, 以及SiC衬底的FTO峰

    Figure 1.  (a) Schematic structure of the GaN-on-SiC HEMT under test in the Raman optothermal measurement; (b) Raman peaks of the GaN-on-SiC HEMT at 50 ℃ and 300 ℃, including the E2(high) and A1(LO) peaks of the GaN epitaxy and the FTO peak of the SiC substrate.

    图 2  (a) GaN A1(LO)拉曼峰随温度的变化关系, 线性拟合得到的温度系数为–0.026 cm–1·K–1; (b) SiC FTO拉曼峰随温度的变化关系, 线性拟合得到的温度系数为–0.023 cm–1·K–1

    Figure 2.  (a) Position of the GaN A1(LO) Raman peak as a function of temperature. The temperature coefficient from the linear fit is –0.026 cm–1·K–1; (b) position of the SiC FTO Raman peak as a function of temperature. The temperature coefficient from the linear fit is –0.023 cm–1·K–1.

    图 3  (a) GaN A1(LO)拉曼峰随器件功率密度的变化关系, 线性拟合得到的功率系数为–1.86 cm–1·mm/W; (b) SiC FTO拉曼峰随器件功率密度的变化关系, 线性拟合得到的功率系数为–1.25 cm–1·mm/W的功率系数

    Figure 3.  (a) Position of the GaN A1(LO) Raman peak as a function of the device power density. The power density coefficient from the linear fit is –1.86 cm–1·mm/W; (b) position of the SiC FTO Raman peak as a function of the device power density. The power density coefficient from the linear fit is –1.25 cm–1·mm/W.

    图 4  (a)铜/石墨法兰封装器件GaN层、SiC上表层和封装法兰的温度随功率密度的变化; (b)铜/石墨法兰封装器件GaN层和SiC上表层的温度差、GaN层和封装法兰之间的温度差随功率密度的变化; (c)铜钼法兰封装器件GaN层、SiC上表层和封装法兰的温度随功率密度的变化; (d)铜钼法兰封装器件GaN层和SiC上表层的温度差、GaN层和封装法兰之间的温度差随功率密度增加的变化

    Figure 4.  (a) Measured temperature of GaN, SiC, and the Cu/graphite flange as a function of the device power density; (b) temperature differences between GaN and SiC, and between GaN and and the Cu/graphite flange as a function of the device power density; (c) measured temperature of GaN, SiC, and the CuMo flange as a function of the device power density; (b) temperature differences between GaN and SiC, and between GaN and and the CuMo flange as a function of the device power density.

    图 5  (a)铜/石墨法兰封装的GaN器件的GaN外延和SiC衬底上表层温度的模拟值(线)和实测值(点); (b)铜钼法兰GaN电子器件的结温和SiC衬底上表层温度的模拟值和实测值的对比; (c) 1.43 W/mm功率密度下铜/石墨法兰和铜钼法兰封装GaN器件在垂直器件表面方向上的温度分布; (d)铜/石墨法兰和铜钼法兰封装GaN器件各层材的热阻占比(其中TBR的材料为AlN)

    Figure 5.  (a) Simulated (line) and measured (dot) junction temperatures of the Cu/graphite flanged device; (b) simulated (line) and measured (dot) junction temperatures of the CuMo flanged device; (c) depth wise temperature distribution of the Cu/graphite flanged device and the CuMo flanged device at the power density of 1.43 W/mm; (d) thermal resistance of each layer within the Cu/graphite flanged device and the CuMo flanged device (The material of TBR is AlN).

    表 1  两种铜基法兰封装GaN器件的热阻对比

    Table 1.  Thermal resistance of GaN HEMT with different Cu-based flange materials.

    GaN场效应管法兰封装材料热导率/W·(m·K)–1GaN-SiC间热阻/mm·K·W–1器件整体热阻/mm·K·W–1
    铜/石墨30014.742.9
    铜钼16714.452.8
    下载: 导出CSV

    表 2  有限元热仿真分析中使用的各层材料的尺寸及热导率

    Table 2.  Dimensions and thermal conductivity of each layer in the GaN-on-SiC HEMT used in the finite element device thermal simulation.

    材料厚度/μm热导率/ W·(m·K) –1
    AlGaN/GaN1.2160 × (T/300)–1.42[23]
    AlN0.02拟合提取出等效界面热阻约为50 m2·K/GW
    SiC100400 × (T/300)–1[23]
    AuSn1257[24]
    铜钼1000167[24]
    铜/石墨1000300
    下载: 导出CSV
  • [1] Huang H, Sun Z, Cao Y, Li F, Zhang F, Wen Z, Hu L 2018 J. Phys. D: Appl. Phys. 51 345102 doi: 10.1088/1361-6463/aad455
    [2] Huang H, Li F, Sun Z, Cao Y 2018 Micromachines 9 658 doi: 10.3390/mi9120658
    [3] Bagnall K R, Saadat O I, Joglekar S, Palacios T, Wang E N 2017 IEEE Trans. Electron Devices. 64 2121 doi: 10.1109/TED.2017.2679978
    [4] Chen K J, Häberlen O, Lidow A, Tsai C L, Ueda T, Uemoto Y, Wu Y 2017 IEEE Trans. Electron Devices. 64 779 doi: 10.1109/TED.2017.2657579
    [5] 张志荣, 房玉龙, 尹甲运, 郭艳敏, 王波, 王元刚, 李佳, 芦伟立, 高楠, 刘沛, 冯志红 2018 物理学报 67 076801 doi: 10.7498/aps.67.20172581 Zhang Z R, Fang Y L, Yin J Y, Guo Y M, Wang B, Wang Y G, Li J, Lu W L, Gao N, Liu P, Feng Z H 2018 Acta Phys. Sin. 67 076801 doi: 10.7498/aps.67.20172581
    [6] 唐文昕, 郝荣晖, 陈扶, 于国浩, 张宝顺 2018 物理学报 67 198501 doi: 10.7498/aps.67.20181208 Tang W X, Hao R H, Chen F, Yu G H, Zhang B S 2018 Acta Phys. Sin. 67 198501 doi: 10.7498/aps.67.20181208
    [7] Wu Y F, Moore M, Saxler A, Wisleder T, Parikh P 2006 64th Device Research Conference IEEE State College, PA, USA, June 26–28, 2006 p151
    [8] Zhou Y, Anaya J, Pomeroy J, Sun H, Gu X, Xie A, Kuball M 2017 ACS Appl. Mater. Interfaces 9 34416 doi: 10.1021/acsami.7b08961
    [9] Sun H R, Pomeroy J W, Simon R B, Francis D, Faili F, Twitchen D J, Kuball M 2016 IEEE Electron Device Lett. 37 621 doi: 10.1109/LED.2016.2537835
    [10] Won Y, Cho J, Agonafer D, Asheghi M, Goodson K E 2015 IEEE Trans. Compon., Packag., Manuf. Technol. 5 737 doi: 10.1109/TCPMT.2015.2433132
    [11] Sun H R, Simon R B, Pomeroy J W, Francis D, Faili F, Twitchen D J, Kuball M 2015 Appl. Phys. Lett. 106 111906 doi: 10.1063/1.4913430
    [12] Yan Z, Liu G, Khan J M, Balandin A A 2012 Nat. Commun. 3 827 doi: 10.1038/ncomms1828
    [13] Ma Z H, Cao H C, Lin S, Li X D, Zhao L X 2019 Solid-State Electron. 156 92 doi: 10.1016/j.sse.2019.01.004
    [14] Manoi A, Pomeroy J W, Killat N, Kuball M 2010 IEEE Electron Device Lett. 31 1395 doi: 10.1109/LED.2010.2077730
    [15] 张昊明, 何新波, 沈晓宇, 刘谦, 曲选辉 2012 粉末冶金材料科学与工程 17 339 doi: 10.3969/j.issn.1673-0224.2012.03.011 Zhang Y M, He X B, Shen X Y, Liu Q, Qu X H 2012 Mater. Sci. Eng. Powder. Metall. 17 339 doi: 10.3969/j.issn.1673-0224.2012.03.011
    [16] 许尧, 薛鹏举, 魏青松, 史玉生 2013 热加工工艺 42 111 Xu Y, Xue P J, Wei Q S, Shi Y S 2013 Hot Working Technol. 42 111 (in Chinese)
    [17] Fu J J, Zhao L X, Cao H C, Sun X J, Sun B J, Wang J X, Li J M 2016 AIP Adv. 6 055219 doi: 10.1063/1.4953056
    [18] Kuball M, Pomeroy J W 2016 IEEE Trans. Device Mater. Reliab. 16 667 doi: 10.1109/TDMR.2016.2617458
    [19] Pomeroy J W, Bernardoni M, Dumka D C, Fanning D M, Kuball M 2014 Appl. Phys. Lett. 104 083513 doi: 10.1063/1.4865583
    [20] Anaya J, Rossi S, Alomari M, Kohn E, Tóth L, Pécz B, Kuball M 2015 Appl. Phys. Lett. 106 223101 doi: 10.1063/1.4922035
    [21] Pomeroy J W, Middleton C, Singh M, Dalcanale S, Uren M J, Wong M H, Kuball M 2018 IEEE Electron Device Lett. 40 189
    [22] Sarua A, Ji H, Kuball M, Uren M J, Martin T, Hilton K P, Balmer R S 2006 IEEE Trans. Electron Devices. 53 2438 doi: 10.1109/TED.2006.882274
    [23] Wang A, Tadjer M J, Calle F 2013 Semicond. Sci. Technol. 28 055010 doi: 10.1088/0268-1242/28/5/055010
    [24] Guo H, Kong Y, Chen T 2017 Diamond Relat. Mater. 73 260 doi: 10.1016/j.diamond.2016.10.006
    [25] Zou B, Sun H R, Guo H X, Dai B, Zhu J Q 2019 Diamond Relat. Mater. 95 28 doi: 10.1016/j.diamond.2019.03.020
    [26] Riedel G J, Pomeroy J W, Hilton K P, Maclean J O, Wallis D J, Uren M J, Pozina G 2008 IEEE Electron Device Lett. 30 103
    [27] Liu K, Zhao J W, Sun H R, Guo H X, Dai B, Zhu J Q 2019 Chin. Phys. B 28 060701 doi: 10.1088/1674-1056/28/6/060701
  • 加载中
图( 5) 表( 2)
计量
  • 文章访问数:  127
  • HTML全文浏览数:  127
  • PDF下载数:  1
  • 施引文献:  0
出版历程
  • 收稿日期:  2019-06-14
  • 刊出日期:  2020-01-01

基于拉曼热测量技术的铜基复合物法兰GaN基晶体管的热阻分析

    通讯作者: E-mail: huarui.sun@hit.edu.cn
    作者简介: lkqm22@163.com
  • 1. 哈尔滨工业大学(深圳)理学院, 深圳 518055
  • 2. 哈尔滨工业大学(深圳), 工业和信息化部微纳光电信息系统重点实验室, 深圳 518055

摘要: 采用拉曼热测量技术结合有限元热仿真模型, 分析比较新型铜/石墨复合物法兰封装与传统铜钼法兰封装的GaN器件的结温与热阻, 发现前者的整体热阻比铜钼法兰器件的整体热阻低18.7%, 器件内部各层材料的温度分布显示铜/石墨复合物法兰在器件中的热阻占比相比铜钼法兰在器件中的热阻占比低13%, 这证明使用高热导率铜/石墨复合物法兰封装提高GaN器件热扩散性能的有效性. 通过对两种GaN器件热阻占比的测量与分析, 发现除了封装法兰以外, 热阻占比最高的是GaN外延与衬底材料之间的界面热阻, 降低界面热阻是进一步提高器件热性能的关键. 同时, 详细阐述了使用拉曼光热技术测量GaN器件结温和热阻的原理和过程, 展示了拉曼光热技术作为一种GaN器件热特性表征方法的有效性.

English Abstract

    • GaN基高电子迁移率晶体管(HEMT)得益于其高频率响应和高击穿电压特性, 成为高频和高功率等领域应用的有力竞争者[1-6]. 近年来, GaN晶体管的功率密度得到显著的提高[7], 高功率密度会在器件沟道内产生大量的焦耳热[8], 使得GaN器件的可靠性和器件性能降低[9-11]. 因此GaN器件的热管理问题成为限制其在大功率、高频率等领域应用进一步发展的重要原因之一, 也成为目前针对GaN器件可靠性方面的研究焦点[12,13]. GaN器件的工作结温由从外延层、成核层和衬底层到芯片黏连层、法兰封装材料等各层材料的热扩散性能决定. 因此, 准确表征各层材料在器件中的热阻占比对器件热设计和可靠性评估非常重要. 在上述各层热阻中, GaN器件的近结热阻受到材料本征热输运性质以及器件对材料厚度要求的限制, 但可以通过成核层材料的生长条件调控GaN外延与衬底间的界面热阻[14]. 另一方面, 可以通过使用更高热导率的法兰材料减小封装部分的热阻, 例如石墨与铜形成的复合材料具有与半导体材料相近的热膨胀系数、较低的密度及较高的热导率[15,16]. 其中, 采用放电等离子或热压烧结制备出的铜/石墨复合材料的热导率可达300—400 W/(m·K)[15,16], 被视为非常有潜力的电子封装材料.

      本文通过拉曼热测量技术准确表征了热压烧结法制备的铜/石墨复合物法兰封装的GaN场效应管在不同功率下的结温, 结合拉曼热测试与有限元热仿真结果的比对分析得到GaN器件的各层热阻, 并与由传统铜钼法兰封装的GaN器件进行对比. 结果发现由高热导率铜/石墨复合物法兰封装的GaN器件的整体热阻比由铜钼法兰封装的GaN电子器件的整体热阻低18.7%, 从器件层面证明使用铜/石墨法兰封装降低GaN器件热阻、提高热扩散能力的可行性. 同时, 本文也阐明应用拉曼热测量技术结合热仿真模型分析GaN电子器件各部分热阻的具体方法和独特优势.

    • 本文测量的器件是以SiC为衬底的GaN基微波晶体管, AlGaN/GaN外延的厚度为1.2 μm, SiC衬底的厚度为100 μm, 在SiC衬底和GaN外延之间有20 nm的AlN成核层. 铜/石墨法兰是以天然鳞片石墨粉和纯铜粉为原料, 通过真空热压烧结制备而成, 法兰厚度为1 mm, 用激光闪射法导热仪测量的热导率为300 W/(m·K), 而对比器件的封装是传统常用的铜钼法兰, 热导率为167 W/(m·K). 在法兰和SiC衬底之间有12 μm的AuSn合金黏附层. 被测器件的结构示意图如图1(a)所示. 器件单指栅宽300 μm, 总栅宽19.2 mm, 栅极间距为38 μm和82 μm交替排列. 虽然不同测试方法的测量机理不同, 测量结果会有差异[17]. 但GaN电子器件的焦耳自生热主要产生在栅极脚下靠近漏极一侧的狭小空间内, 通常只有微米尺度. 因此在现代GaN电子器件热阻的表征手段中, 具有较高空间分辨率的拉曼热测量和热成像技术是相对较为成熟且准确性相对较高的方法[17-21].

      如图1(a)所示, 由于拉曼热测量技术中所使用的532 nm激光可以穿透同为宽禁带半导体的GaN和SiC, 而且拉曼光谱具有材料选择性, 因此被测器件GaN外延层和SiC衬底层的拉曼峰信息可被同时提取. 测量时激光透过数值孔径NA = 0.5的物镜, 聚焦在器件栅极脚下靠近漏极的一侧的AlGaN/GaN表面, 该区域电场强度最高, 为沟道内温度最高的区域. 拉曼热测量技术的原理是利用被测材料的拉曼特征峰具有温度依赖性, 这是晶格常数随着温度变化而改变, 而相应的声子振动模式的频率随之改变产生的. 对GaN和SiC来讲, 这种温度依赖性在室温以上是线性的, 即GaN和SiC的拉曼特征峰会随着温度的升高呈现线性的偏移[22], 通过偏移的波数值可以得到材料的温度升高值. 图1(b)为被测器件在50 ℃和300 ℃下的拉曼光谱, 包括GaN外延的E2(high)和A1(LO)峰, 以及SiC衬底的FTO峰, 可以看到GaN和SiC的特征峰随着温度升高发生红移.

      为准确表征器件沟道和衬底上表层的温度, 首先对器件中GaN和SiC的温度系数进行校准. 在校准的过程中使用高精度温控台严格控制器件的温度, 从室温开始, 每升高25 ℃测量1次GaN和SiC的拉曼特征峰, 直到300 ℃. 图2(a)和图2(b)分别显示了被测器件GaN A1(LO)峰和SiC FTO峰位置随温度变化的关系, 通过线性拟合得到GaN A1(LO)峰的温度系数为–0.026 cm–1·K–1, SiC FTO峰的温度系数为–0.023 cm–1·K–1.

      得到校准的温度系数后, 测量器件在不同功率工作状态下GaN A1(LO)峰和SiC FTO峰的偏移. 由于器件的生热量随功率密度成正比例增加, GaN和SiC相应位置的温度也随功率密度的增加而升高, 造成的拉曼峰移随功率密度的线性关系的斜率称为GaN A1(LO)峰和SiC FTO峰的功率系数. 我们使用双通道直流电源分别给GaN器件的栅-源两极和漏-源两极之间施加电压, 用万用表测量漏极电流. 从器件关断状态(栅极负压)开始, 功率密度大约每增加0.3 W/mm需多次测量GaN A1(LO)峰和SiC FTO峰的峰位. 多次测量是为了尽可能的减少测量的不确定性, 提高测量准确度. 整个测量过程中将热电偶放置在电路板上靠近器件工作区域的位置, 测得的不同功率密度下的板温作为器件封装法兰背板的温度. 图3(a),(b)分别显示了被测器件GaN A1(LO)峰、SiC FTO峰随着功率密度升高的偏移, 通过线性拟合得到GaN A1 (LO)峰的功率系数为 –1.86 cm–1·mm/W, SiC FTO峰的功率系数为 –1.25 cm–1·mm/W.

      以特征峰的偏移作为中间变量即可得出不同功率密度下对应的器件中GaN外延的温度和衬底上表层的温度, 结合由热电偶测量的封装法兰的温度, 可以得到不同功率密度下对应的器件中沿纵向延伸不同深度处的温度. 需要强调的是, 拉曼光热实验中使用的激光波长(λ = 532 nm)和透镜的数值孔径 (NA = 0.5)决定了激光聚焦在GaN表面时景深为8—10 μm[18], 所以对透明的GaN来说拉曼探测的有效区域是整个GaN外延层厚度, 对SiC拉曼探测的有效区域是SiC衬底上表层(即界面处)的7—9 μm, 而通过拉曼峰移得到的温度是有效区域的平均温度. 实际上, 1—2 μm GaN外延层厚度的平均温度同器件结温非常接近, 详见第3节中的结果与讨论.

    • 图4(a)显示了被测铜/石墨法兰封装器件GaN层、SiC上表层和封装法兰的温度随功率密度增加成线性增加的关系, 图中的点代表使用拉曼热测量的实验值, 拟合直线的斜率代表每增加1 W/mm功率密度对应各部分的温度升高值, 即与环境温度间的热阻. GaN层和SiC上表层的温度差随功率密度增加的变化系数描述了器件中GaN外延层和SiC衬底层之间的热阻; GaN层和封装法兰之间的温度差随功率密度增加的变化系数描述了器件的整体热阻, 如图4(b)所示. 被测铜/石墨法兰器件中GaN与SiC之间的热阻为14.7 mm·K/W, 器件整体热阻为42.9 mm·K/W. 作为对比, 图4(c)是被测铜钼法兰封装器件GaN层、SiC上表层和封装法兰的温度随功率密度增加的变化情况; 图4(d)是铜钼法兰封装器件GaN层和SiC上表层的温度差、GaN层和封装法兰之间的温度差随功率密度升高的变化. 器件中GaN与SiC之间的热阻为14.4 mm·K/W, 而器件整体热阻为52.8 mm·K/W. 如表1所示, 两种铜基法兰封装的GaN器件中GaN与SiC间的热阻几乎相等, 这是材料界面层生长一致性的必然结果; 而铜/石墨法兰器件的整体热阻相比铜钼法兰器件低18.7%, 这是铜/石墨法兰材料的高热导率造成的.

      为了更好地理解器件各层的热阻占比, 根据被测器件的实际几何尺寸以及实验测量的条件使用有限元热仿真模型模拟器件在对应功率密度下各层的温度, 其中使用的各层材料的几何参数和热学性质参数在表2中列出. GaN, SiC, AuSn等材料的热导率都是器件常用的文献值[23,24], 法兰封装材料的热导率是供应商提供的激光闪射导热仪的测量值. 热模拟中器件工作的功率密度作为热源的功率密度控制在0—1.7 W/mm范围内, 实验测得的法兰温度作为器件的边界温度. GaN与SiC之间的等效界面热阻, 包含20 nm厚成核层材料AlN的热阻以及GaN/AlN与AlN/SiC两个界面热阻, 被当作变量用于拟合GaN与SiC上表面温度的测量值. 当GaN-SiC等效界面热阻为50 m2·K/GW时, GaN与SiC温度的模拟值与测量结果匹配. 关于热仿真模型的更多细节可以参考本课题组的另一篇文章[25]. 值得注意的是, 这里用来拟合的GaN与SiC的温度为前文所述的拉曼探测有效区域的温度平均值, 而图5(a)和图5(b)分别显示铜/石墨法兰和铜钼法兰封装的GaN器件的结温(即GaN上表面峰值温度)和AlN/SiC界面温度的模拟值和实测值的对比, 会比GaN与SiC中探测有效区域的实测平均值略高(3%), 这个结果表明拉曼热测量技术的结果在GaN外延厚度不大(1 μm左右)的情况下足够接近GaN表面的峰值温度, 能较为准确和可靠地用于GaN器件结温和器件失效时间的评估.

      通过热仿真还可以得出被测GaN电子器件在垂直器件表面方向上的温度分布, 以及各层材料的热阻占比, 这样可以更直观地了解器件内部的热输运过程, 如图5(c)和图5(d)所示. 图5(c)为功率密度为1.43 W/mm情况下铜/石墨法兰器件和铜钼法兰器件的纵向温度分布, 图中的实线即为模拟值, 点则代表实际测量值, 拟合得到的GaN与SiC之间的等效界面热阻为50 m2·K/GW. 在功率密度均为1.43 W/mm的情况下, 铜/石墨法兰器件的模拟结温128.4 ℃比铜钼法兰器件的模拟结温151.3 ℃降低15.1 %; 两个器件唯一的差别就是封装材料不同, 表明器件导热性能的改良得益于封装材料热导率的提高. 如表2所示, 被测器件的铜/石墨复合法兰的热导率可达300 W/(m·K), 比铜/鉬法兰的热导率167 W/(m·K)高79.6 %. 此外, 从图4(a)和图4(c)的对比中可以发现, 铜/石墨法兰封装的器件中GaN外延、SiC衬底上表层、法兰背板的温度随功率密度升高的变化系数相比铜钼法兰封装器件的对应值分别降低17%, 21%, 11%, 表明在相同的功率密度下, 铜/石墨法兰器件的各层温度均低于相应的铜钼法兰器件的各层温度. 图5(d)直观地展示了1.43 W/mm功率密度下铜/石墨法兰器件和铜钼法兰器件的各层材料热阻占比. 对于整个器件来讲热阻占比最大的部分就是封装法兰, 其中铜/石墨法兰约占GaN电子器件整体热阻的40%, 铜钼法兰约占GaN电子器件整体热阻的53 %. 相较于铜钼法兰, 铜/石墨法兰的热阻占比降低了13%, 这个结果使器件的整体热阻降低18.7%. 本文所测的铜/石墨法兰的热导率为300 W/(m·K), 根据文献[16]的结果, 该热导率对应的石墨质量分数近似为50%. 如果进一步提高铜/石墨法兰的热导率, 比如石墨质量分数为40%的铜/石墨复合材料热导率可达378 W/(m·K)[16], 通过热仿真模拟的结果表明可以使器件的整体热阻降低19.8%. 通过调整铜/石墨复合材料中石墨的质量分数可以使法兰的热导率达到最佳. 这是因为虽然石墨本身的热导率高于铜的热导率, 但是随着石墨质量分数的增加, 铜与石墨的界面也会增加, 同时受热压烧结工艺的影响, 材料中的空隙也会增多, 这些因素均导致材料中的自由电子和声子散射的增多, 从而降低材料的热导率. 对图5(c)和图5(d)的分析还可以发现, 对于整个器件来说, 热阻占比较高的除了法兰之外, 还有界面热阻, 其占铜/石墨法兰器件整体热阻的22%和占铜钼法兰器件整体热阻的18%. 本文中拟合得到的GaN-on-SiC电子器件的界面热阻约为50 m2·K/GW, 与Riedel等[26]采用拉曼热成像技术的测量结果约47 m2·K/GW相近, 但是比本课题组采用瞬态热反射法测量的另一种工艺生长的SiC基GaN外延片的界面热阻约25 m2·K/GW高了1倍[27]. 通过有限元模拟发现, 如果器件的界面热阻降低到25 m2·K/GW, 则结温会进一步降低2.7%, 整体热阻会相应地降低5.6%. GaN晶片的界面热阻受外延生长工艺影响, 尤其是成核层内部或者界面附近的微观结构和缺陷会通过增加声子散射率、降低声子的平均自由程来阻碍热传递. 研究表明, 与常用的金属有机化学气相沉积相比, 热壁外延技术可以有效地降低GaN外延和SiC衬底之间的界面热阻[26]. 这是因为热壁外延技术生长的AlN成核层更趋向于单晶, 这导致了较少的缺陷、晶粒和晶界的声子散射, 因此成核层具有更高的热导率. 界面热阻的降低将会进一步提高器件的热扩散性能.

    • 利用拉曼热测量技术结合有限元热仿真模型分析并对比两种铜基复合物材料法兰封装的GaN高电子迁移率晶体管的热阻, 发现由铜/石墨法兰封装的GaN器件的整体热阻比由铜钼法兰封装的同种GaN器件的降低了18.7%, 在1.43 W/mm功率密度下的结温降低15%以上, 法兰的热阻占比降低约13%. 这证明使用铜/石墨法兰封装提高GaN器件热扩散能力的可行性, 同时也充分说明了拉曼热测量技术与有限元热仿真模型结合的方法是对GaN器件结温及各层热阻表征分析的有效工具. 此外, 从对器件热阻占比的分析发现, GaN与SiC之间的等效界面热阻需要大幅减小以进一步地降低器件热阻, 这可以通过材料生长过程的调控来实现.