食品接触塑料中6种金属离子迁移量测定方法研究

上一篇

下一篇

凌光耀, 熊小婷, 刘春生, 陈意光, 江奋万, 仇旭前, 李慧勇, 黄晓钢, 何国山. 食品接触塑料中6种金属离子迁移量测定方法研究[J]. 质谱学报, 2025, 46(2): 217-223. doi: 10.7538/zpxb.2024.0112
引用本文: 凌光耀, 熊小婷, 刘春生, 陈意光, 江奋万, 仇旭前, 李慧勇, 黄晓钢, 何国山. 食品接触塑料中6种金属离子迁移量测定方法研究[J]. 质谱学报, 2025, 46(2): 217-223. doi: 10.7538/zpxb.2024.0112
Guang-yao LING, Xiao-ting XIONG, Chun-sheng LIU, Yi-guang CHEN, Fen-wan JIANG, Xu-qian QIU, Hui-yong LI, Xiao-gang HUANG, Guo-shan HE. Determination of Migration of Six Metal Ions in Food Contact Plastic[J]. Journal of Chinese Mass Spectrometry Society, 2025, 46(2): 217-223. doi: 10.7538/zpxb.2024.0112
Citation: Guang-yao LING, Xiao-ting XIONG, Chun-sheng LIU, Yi-guang CHEN, Fen-wan JIANG, Xu-qian QIU, Hui-yong LI, Xiao-gang HUANG, Guo-shan HE. Determination of Migration of Six Metal Ions in Food Contact Plastic[J]. Journal of Chinese Mass Spectrometry Society, 2025, 46(2): 217-223. doi: 10.7538/zpxb.2024.0112

食品接触塑料中6种金属离子迁移量测定方法研究

    通讯作者: 本文通信作者陈意光; 
  • 中图分类号: O657.63

Determination of Migration of Six Metal Ions in Food Contact Plastic

    Corresponding author: Yi-guang CHEN, 32093412@qq.com
  • MSC: O657.63

  • 摘要: 本研究利用金属离子可与乙腈、甲酸形成稳定团簇离子的性质,建立了液相色谱-四极杆-飞行时间质谱(LC-QTOF MS)法测定食品接触塑料中Cd2+、Co2+、Cu2+、Mn2+、Ni2+、Zn2+等6种金属离子迁移量。采用Ultimate Hilic amide色谱柱,以0.02%甲酸溶液-乙腈为流动相进行梯度洗脱,在电喷雾离子源正离子(ESI+)模式下,采用多反应监测-高分辨(MRM HR)模式检测。结果表明,本方法的检出限为0.02~0.08 mg/kg,回收率为88.6%~115%,相对标准偏差(RSD)为0.3%~6.1%。采用本方法检测24批次食品接触塑料样品的迁移液,在4批次样品迁移液中检出Cu2+、Mn2+、Zn2+。该方法可直接检测高乙醇比例溶液中金属离子浓度,用于食品接触塑料中钴、铜、锰、锌元素的合规性筛查,对食品接触塑料中未知风险物质的分析有着较好的参考价值。
  • 加载中
  • 图 1  Zn2+的一级(a)和二级(b)质谱图

    Figure 1.  MS (a) and MS/MS (b) spectra of Zn2+

    图 2  标准溶液提取离子色谱图

    Figure 2.  Extract ion chromatograms of the standard solution

    表 1  各离子的监测离子对及对应的化学式

    Table 1.  Ion pairs and possible corresponding chemical formulas

    序号
    No.
    离子
    Ion
    离子对
    Ion pair (m/z)
    可能的对应离子 Possible corresponding ion
    母离子
    Parent ion
    定量离子
    Quantitative ion
    定性离子
    Qualitative ion
    其他子离子
    Other ion
    1 Cd2+ 199.93>158.901*, 155.938 [Cd(HCOO)+CH3CN]+ [Cd(HCOO)]+ [Cd(H)+CH3CN]+ [Cd]+,[Cd(H)]+
    2 Co2+ 144.96>100.968*, 59.941 [Co(HCOO)+CH3CN]+ [Co(H)+CH3CN]+ [Co(H)]+ [Co(HCOO)]+,[Co]+,[Co+CH3CN]+
    3 Cu2+ 144.98>103.956*, 62.930 [Cu+2CH3CN]+ [Cu+CH3CN]+ [Cu]+ [Cu+CH3CN+N2]+
    4 Mn2+ 140.96>96.972*, 99.936 [Mn(HCOO)+CH3CN]+ [Mn(H)+CH3CN]+ [Mn(HCOO)]+ [Mn]+,[Mn(H)]+
    5 Ni2+ 143.96>98.962*, 99.970 [Ni(HCOO)+CH3CN]+ [Ni+CH3CN]+ [Ni(H)+CH3CN]+ [Ni]+,[Ni(H)]+,[Ni+CH3CN+N2]+
    [NiO+CH3CN]+,[Ni(OH)+CH3CN]+
    6 Zn2+ 149.95>105.964*, 64.937 [Zn(HCOO)+CH3CN]+ [Zn(H)+CH3CN]+ [Zn(H)]+ [Zn]+,[Zn(HCOO)]+
    注:*表示定量离子
    下载: 导出CSV

    表 2  各离子的工作曲线及仪器检出限

    Table 2.  Working curves and instrument detection limits of the ions

    序号
    No.
    离子
    Ion
    保留时间
    Retention time/min
    线性范围
    Linear range/
    (μg/L)
    工作曲线
    Working curve
    相关系数
    Correlation coefficient
    r2
    检出限
    LOD/
    (μg/L)
    1 Cd2+ 3.8 50~800
    50~800
    y=46.42x+86.21 0.9996 20
    y=42.93x−30.43 0.9975 20
    2 Co2+ 3.7 50~800
    50~800
    y=137.3x+1518 0.9992 20
    y=130.4x+1449 0.9995 20
    3 Cu2+ 3.8 100~1600
    200~1600
    y=959.7x−5164 0.9997 40
    y=1782x−2.039×105 0.9984 80
    4 Mn2+ 3.8 200~1600
    200~1600
    y=123.5x+2135 0.9992 80
    y=120.0x+191.6 0.9959 80
    5 Ni2+ 3.7 200~1600
    200~1600
    y=26.70x+3722 0.9969 80
    y=27.82x+1.077×105 0.9995 80
    6 Zn2+ 3.8 100~1600
    100~1600
    y=118.3x+5222 0.9985 40
    y=106.5x+4223 0.9996 40
    下载: 导出CSV

    表 3  各食品模拟物中的加标回收率和相对标准偏差

    Table 3.  Recoveries and relative standard deviations in different food simulants

    序号
    No.
    加标浓度1)
    Spiked level/(mg/kg)
    方法检出限
    LOD/(mg/kg)
    加标回收率Recovery/% (相对标准偏差RSD/%)

    Water
    4%乙酸
    4%AcOH
    10%乙醇
    10%EtOH
    20%乙醇
    20%EtOH
    50%乙醇
    50%EtOH
    95%乙醇
    95%EtOH
    1 0.05 0.02 96.8(5.3) 98.6(4.2) 101.0(1.9) 96.2(3.9) 99.3(2.1) 99.8(3.8)
    0.40 101.0(2.6) 95.8(2.1) 100.9(2.4) 100.8(2.9) 102.0(2.2) 99.9(2.7)
    0.80 97.8(1.6) 93.0(2.6) 97.4(1.9) 100.8(1.5) 102.0(3.6) 103.0(2.6)
    2 0.05 0.02 108.0(4.4) 97.7(2.5) 106.0(2.0) 97.8(3.4) 98.3(2.2) 91.8(1.5)
    0.40 99.6(1.7) 88.6(1.2) 98.4(1.6) 102.0(1.8) 102.0(2.7) 99.7(1.8)
    0.80 98.1(0.9) 93.2(0.4) 98.6(1.3) 103.0(1.1) 103.0(1.1) 106.0(0.6)
    32) 0.10 0.04/0.083) 97.4(2.9) 102.0(4.2) 99.4(1.8) 97.0(2.9) 90.4(3.4) 98.3(2.1)
    0.80 95.6(3.8) 99.5(3.7) 98.2(4.0) 101.0(2.1) 96.4(5.3) 100.9(3.9)
    1.60 101.0(2.4) 93.9(3.8) 93.3(1.8) 94.8(6.0) 98.5(6.1) 97.3(2.3)
    4 0.20 0.08 101.0(3.5) 106.0(1.0) 98.5(2.4) 97.7(1.9) 98.2(2.2) 100.3(2.7)
    0.80 105.0(1.7) 107.0(1.3) 105.0(1.5) 99.9(1.4) 102.0(1.8) 96.0(1.9)
    1.60 99.0(1.1) 104.0(1.0) 98.7(1.2) 102.0(1.4) 104.0(1.9) 100.1(1.7)
    5 0.20 0.08 98.2(2.9) 88.8(5.4) 97.9(3.6) 99.8(1.6) 99.8(1.4) 97.5(3.2)
    0.80 104.0(1.5) 104.0(1.7) 104.0(2.2) 103.0(2.0) 102.0(4.7) 92.0(3.0)
    1.60 94.1(2.3) 99.5(1.8) 98.9(2.1) 101.0(3.6) 105.0(6.1) 103.0(1.5)
    6 0.10 0.04 102.0(1.5) 115.0(3.8) 99.7(4.3) 112.0(3.3) 114(3.6) 99.1(4.8)
    0.80 97.9(0.9) 96.2(2.6) 99.1(1.5) 102.0(4.5) 103.0(0.9) 99.5(2.8)
    1.60 99.5(0.3) 91.8(0.8) 99.3(1.3) 100.9(1.0) 101.0(0.8) 99.0(0.9)
    注:1)食品模拟物密度以1 kg/L计,最低加标浓度为方法定量限;2)水、4%乙酸、10%乙醇、20%乙醇、50%乙醇的加标浓度为0.10、0.80、1.60 mg/kg,95%乙醇的加标浓度为0.20、0.80、1.60 mg/kg;3)水、4%乙酸、10%乙醇、20%乙醇、50%乙醇的方法检出限为0.04 mg/kg,95%乙醇的方法检出限为0.08 mg/kg
    下载: 导出CSV
  • [1] GB 9685−2016 食品安全国家标准 食品接触材料及制品用添加剂使用标准[S]. 北京: 中国标准出版社, 2017.
    [2] GB 4806.4−2016 食品安全国家标准 陶瓷制品[S]. 北京: 中国标准出版社, 2017.
    [3] GB 4806.5−2016 食品安全国家标准 玻璃制品[S]. 北京: 中国标准出版社, 2017.
    [4] 宋逍冲, 庞金玲, 黄晓佳. 食品中重金属检测及样品前处理方法研究进展[J]. 食品安全质量检测学报, 2020, 11(15): 4 958-4 966. SONG Xiaochong, PANG Jinling, HUANG Xiaojia. Research progress on the detection of heavy metals and sample preparation methods in food samples[J]. Journal of Food Safety and Quality, 2020, 11(15): 4 958-4 966(in Chinese).
    [5] 杨红本, 杨凡, 胡赠彬, 白祥. 食品中无机元素分析方法研究进展[J]. 食品安全质量检测学报, 2017, 8(10): 3 935-3 943. YANG Hongben, YANG Fan, HU Zengbin, BAI Xiang. Advances in the analysis methods of inorganic elements in foods[J]. Journal of Food Safety & Quality, 2017, 8(10): 3 935-3 943(in Chinese).
    [6] 董娜, 罗蓰超, 李伟航, 杨忠宝. 液相色谱-蒸汽发生-原子荧光联用技术测定食品中砷、汞的形态[J]. 江苏调味副食品, 2023(4): 30 - 33 . DONG Na, LUO Xichao, LI Weihang, YANG Zhongbao. Determination of As and Hg in food by liquid chromatography-steam occurrence-atomic fluorescence technology[J]. Jiangsu Condiment and Subsidiary Food, 2023(4): 30 - 33 (in Chinese).
    [7] 李俞洁, 陈景周. 食品中铬形态的分析研究进展[J]. 广东化工, 2023, 50(20): 59 - 61 . doi: 10.3969/j.issn.1007-1865.2023.20.020 LI Yujie, CHEN Jingzhou. Research progress on the analysis of chromium forms in food[J]. Guangdong Chemical Industry, 2023, 50(20): 59 - 61 (in Chinese). doi: 10.3969/j.issn.1007-1865.2023.20.020
    [8] GB 31604.49−2023 食品安全国家标准 食品接触材料及制品 多元素的测定和多元素迁移量的测定[S]. 北京: 中国标准出版社, 2023.
    [9] 王进, 王娟, 高辉, 张允武, 盛六四. 过渡金属离子与乙腈团簇的反应[J]. 化学学报, 2002, 60(9): 1 591-1 595. WANG Jin, WANG Juan, GAO Hui, ZHANG Yunwu, SHENG Liusi. Reactions of transition metals with acetonitrile clusters[J]. Acta Chimica Sinica, 2002, 60(9): 1 591-1 595(in Chinese).
    [10] 罗涛, 谢亚菁, 周浩, 唐晓闩. 过渡金属离子Ni+与甲醇、乙醇团簇反应的质谱研究[J]. 科技视界, 2015(17): 32 - 33, 245 . doi: 10.3969/j.issn.2095-2457.2015.17.021 LUO Tao, XIE Yajing, ZHOU Hao, TANG Xiaoshuan. Experimental study on the reaction of metal ions Ni+ with methanol and ethanol clusters by mass spectrometry[J]. Science & Technology Vision, 2015(17): 32 - 33, 245 (in Chinese). doi: 10.3969/j.issn.2095-2457.2015.17.021
    [11] ROSS A R, IKONOMOU M G, THOMPSON J A, ORIANS K J. Determination of dissolved metal species by electrospray ionization mass spectrometry[J]. Analytical Chemistry, 1998, 70(11): 2 225-2 235.
    [12] TSIERKEZOS N G, SCHRÖDER D, SCHWARZ H. Complexation of nickel(II) by ethylenediamine investigated by means of electrospray ionization mass spectrometry[J]. International Journal of Mass Spectrometry, 2004, 235(1): 33 - 42 . doi: 10.1016/j.ijms.2004.03.005
    [13] BARAŁKIEWICZ D, KÓZKA M, PIECHALAK A, TOMASZEWSKA B, SOBCZAK P. Determination of cadmium and lead species and phytochelatins in pea (Pisum sativum) by HPLC-ICP-MS and HPLC-ESI-MSn[J]. Talanta, 2009, 79(2): 493 - 498 . doi: 10.1016/j.talanta.2009.04.026
    [14] WORTMANN A, ROSSI F, LELAIS G, ZENOBI R. Determination of zinc to beta-peptide binding constants with electrospray ionization mass spectrometry[J]. Journal of Mass Spectrometry, 2005, 40(6): 777 - 784 . doi: 10.1002/jms.852
    [15] BERTOLI A C, CARVALHO R, FREITAS M P, RAMALHO T C, MANCINI D T, OLIVEIRA M C, de VARENNES A, DIAS A. Structural determination of Cu and Fe-citrate complexes: theoretical investigation and analysis by ESI-MS[J]. Journal of Inorganic Biochemistry, 2015, 144: 31 - 37 . doi: 10.1016/j.jinorgbio.2014.12.008
    [16] KITOVA E N, EL-HAWIET A, SCHNIER P D, KLASSEN J S. Reliable determinations of protein-ligand interactions by direct ESI-MS measurements. Are we there yet?[J]. Journal of the American Society for Mass Spectrometry, 2012, 23(3): 431 - 441 . doi: 10.1007/s13361-011-0311-9
    [17] WOJCIESZEK J, RUZIK L. Study of bioaccessibility of cobalt species in berries and seeds by mass spectrometry techniques[J]. Journal of Analytical Science and Technology, 2020, 11(1): 26 . doi: 10.1186/s40543-020-00225-7
    [18] GEUE N. Modern electrospray ionization mass spectrometry techniques for the characterization of supramolecules and coordination compounds[J]. Analytical Chemistry, 2024, 96(19): 7 332-7 341.
    [19] TSEDNEE M, HUANG Y C, CHEN Y R, YEH K C. Identification of metal species by ESI-MS/MS through release of free metals from the corresponding metal-ligand complexes[J]. Scientific Reports, 2016, 6: 26 785.
    [20] GB 5009.156−2016 食品安全国家标准 食品接触材料及制品迁移试验预处理方法通则[S]. 北京: 中国标准出版社, 2017.
    [21] GB 31604.1−2015 食品安全国家标准 食品接触材料及制品迁移试验通则[S]. 北京: 中国标准出版社, 2016.
  • 加载中
图( 3) 表( 3)
计量
  • 文章访问数:  44
  • HTML全文浏览数:  44
  • PDF下载数:  0
  • 施引文献:  0
出版历程
  • 收稿日期:  2024-07-01
  • 刊出日期:  2025-03-31

食品接触塑料中6种金属离子迁移量测定方法研究

    通讯作者: 本文通信作者陈意光; 
  • 1. 广州质量监督检测研究院, 国家包装产品质量检验检测中心(广州),广州市NQI-质量安全科技协同创新中心,国家市场监督管理总局技术创新中心(食品相关产品质量与安全),广东 广州 511447
  • 2. 广州市食品检验所,广东 广州 511410

摘要: 本研究利用金属离子可与乙腈、甲酸形成稳定团簇离子的性质,建立了液相色谱-四极杆-飞行时间质谱(LC-QTOF MS)法测定食品接触塑料中Cd2+、Co2+、Cu2+、Mn2+、Ni2+、Zn2+等6种金属离子迁移量。采用Ultimate Hilic amide色谱柱,以0.02%甲酸溶液-乙腈为流动相进行梯度洗脱,在电喷雾离子源正离子(ESI+)模式下,采用多反应监测-高分辨(MRM HR)模式检测。结果表明,本方法的检出限为0.02~0.08 mg/kg,回收率为88.6%~115%,相对标准偏差(RSD)为0.3%~6.1%。采用本方法检测24批次食品接触塑料样品的迁移液,在4批次样品迁移液中检出Cu2+、Mn2+、Zn2+。该方法可直接检测高乙醇比例溶液中金属离子浓度,用于食品接触塑料中钴、铜、锰、锌元素的合规性筛查,对食品接触塑料中未知风险物质的分析有着较好的参考价值。

English Abstract

  • 含钴、铜、锰、镍、锌元素的添加剂允许用于食品接触塑料及制品中,各元素的特定迁移量分别为0.05、5、0.6、0.01、25 mg/kg[1]。Cd是一种重要的有毒重金属,联合国粮农组织和世界卫生组织食品添加剂联合专家委员会(JECFA)提出的Cd元素每月耐受摄入量(PTMI)为25 µg/kg·bw。我国规定了食品接触陶瓷、玻璃制品中Cd元素的迁移限量[2-3]

    目前,常见的金属元素检测方法有比色法、电化学分析法、原子吸收光谱法、原子荧光光谱法、电感耦合等离子体原子发射光谱法、电感耦合等离子体质谱法和X射线荧光光谱法,此外,还包括一些新兴检测方法,如纳米荧光传感器法、免疫检测法、酶传感器法等[4-5]。液相色谱-蒸气发生-原子荧光联用技术、液相色谱(离子色谱)-电感耦合等离子体质谱法也可用于砷、汞、铬等元素的形态分析[6-7]。GB/T 31604−2023[8]规定了多种元素迁移量的测定方法,其中,电感耦合等离子体质谱法的检出限≤0.006 mg/kg,电感耦合等离子体发射光谱法的检出限≤0.03 mg/kg。然而,对于含乙醇的食品模拟物,上述2种方法需先加热去除乙醇(不得蒸干),再用硝酸溶液重新定容后上机测试,前处理费时、效率低。

    激光溅射-分子束-反射式飞行时间质谱技术可检测到多种过渡金属(Ni、Ti、V、Cr、Cu、Fe)与有机小分子(甲醇、乙醇、乙腈)形成的团簇离子,其中金属离子均为+1价[9-10]。溶液中的金属离子能够与乙腈、乙酸、硝酸根、8-羟基喹啉、丁二酮肟、水杨酸、双硫腙、二乙基二硫代氨基甲酸、氯离子[11]、乙二胺、N,N-二甲基甲酰胺[12]、肽[13-14]、柠檬酸[15]、蛋白质[16]、辅酶[17]、超分子[18]、脱氧麦根酸和烟草胺[19]等多种分子形成配位化合物,可通过电喷雾质谱(ESI-MS)检测到。

    本研究利用金属离子与有机小分子形成的团簇离子可被ESI-MS检测的特性,建立液相色谱-四极杆-飞行时间质谱(LC-QTOF MS)法检测食品接触塑料及制品中6种金属离子迁移量。

    • Aquity UPLC H-Class Plus超高效液相色谱仪:美国Waters公司产品;X500B四极杆飞行时间质谱仪:美国SCIEX公司产品,配有电喷雾离子源(ESI)及SCIEX OS集成软件;Milli-Q IQ7000超纯水器:美国Millipore公司产品;Centrifuge 5430R离心机:德国Eppendorf公司产品。

    • Ultimate Hilic amide色谱柱(100 mm×2.1 mm,3 μm):月旭科技公司产品;ChromCore Hilic amide、ChromCore Hilic diol色谱柱(100 mm×2.1 mm,3 μm):纳谱科技公司产品;Cd、Mn(Ⅱ)、Ni标准溶液(1 000 mg/L):美国AccuStandard 公司产品;Co、Cu、Zn标准溶液(1 000 mg/L):国家有色金属及电子材料分析测试中心产品;乙醇、乙腈(色谱纯),甲酸(质谱纯):德国CNW公司产品;乙酸(分析纯):广州化学试剂厂产品;乙醇酸(70%水溶液):上海麦克林生化科技公司产品;甲酸铵(质谱纯):阿拉丁生化科技公司产品;实验用水为超纯水。

      24批次食品接触塑料样品:实验室留样。

    • 混合标准中间液配制:分别移取2.5 mL Cd、Co标准溶液和5 mL Cu、Mn、Ni、Zn标准溶液于50 mL聚丙烯容量瓶中,用水定容至刻度,混匀,于4 ℃保存。其中,Cd2+、Co2+浓度为50 mg/L,Cu2+、Mn2+、Ni2+、Zn2+浓度为100 mg/L。

      混合标准工作液1(用于水、10%乙醇、20%乙醇、50%乙醇、4%乙酸食品模拟物)配制:分别移取0、 0.050、0.100、0.200、0.400、0.600、0.800 mL混合标准中间液于50 mL聚丙烯容量瓶中,加入0.5 mL甲酸,用水定容至刻度,混匀,于4 ℃保存。

      混合标准工作液2(用于95%乙醇食品模拟物)配制:分别移取0、 0.050、0.100、0.200、0.400、0.600、0.800 mL混合标准中间液于50 mL聚丙烯容量瓶中,加入0.5 mL甲酸,用95%乙醇定容至刻度,混匀,于4 ℃保存。

      水、4%乙酸、10%乙醇、20%乙醇、50%乙醇、95%乙醇食品模拟物:按照 GB 5009.156−2016[20]配制。

    • 按照GB 5009.156−2016[20]和GB 31604.1−2015[21]对样品进行迁移实验。对于有标称净含量的金属罐等容器类样品,按标称净含量将相应体积的食品模拟物注入样品中;对于未明确标称净含量的容器类样品,以加入食品模拟物液面与容器类样品上边缘距离不超过1 cm的原则注入食品模拟物;对于涂片等非容器类样品,按常规试样接触面积与食品模拟物体积比S/V(6 dm2接触面积对应1 L或1 kg食品模拟物)将相应体积的食品模拟液注入迁移池中,浸泡样品的食品接触面,按指定的温度和时间进行迁移实验。将完成迁移实验的迁移液转移至试剂瓶中,放置至室温,补齐相应食品模拟物至原体积。将不能立刻进行前处理的迁移液置于4 ℃冰箱中避光保存,进行下一步处理前恢复至室温。

    • 取适量迁移液于2 mL离心管中,以10 000 r/min离心5 min,取1.0 mL上清液于聚丙烯液相小瓶中,加入10 µL甲酸,混匀,待测。

    • Ultimate Hilic amide色谱柱(100 mm×2.1 mm,3 μm);流动相:0.02%甲酸溶液(A)-乙腈(B);流速0.35 mL/min;梯度洗脱程序:0~2.0 min(65%~30%B),2.0~4.0 min(30%B),4.0~5.0 min(30%~65%B),5.0~8.0 min(65%B);柱温为室温;进样量2 μL。

    • 电喷雾离子源正离子(ESI+)模式,多反应监测-高分辨(MRM HR)模式检测,喷雾电压3 000 V,喷雾气压强413 kPa,辅助加热气压强413 kPa,气帘气压强276 kPa,温度600 ℃,碰撞气为7,TOF MS/MS采集时间0.04 s,去簇电压20 V,碰撞能20 V,碰撞能扩展10 V,质谱定量离子对列于表1

    • 本实验对比了甲酸和乙醇酸2种水相流动相添加物与金属离子形成的团簇离子,以及这些团簇离子在质谱检测的表现。结果表明,除Cu2+离子外,其他金属离子在2种不同添加物下均形成了不同的团簇离子。使用乙醇酸作为添加物时,Cd2+形成[CdCl+CH3CN]+离子,其他4种金属离子形成[M(CH2(OH)COO)+CH3CN]+离子。但乙醇酸作为添加物时,质谱总离子流基线较高,且乙醇酸沸点较高,对仪器损耗更大,故选择甲酸作为水相流动相添加物。其中,Zn2+离子的一级和二级质谱图示于图1

      本实验比较了0.02%甲酸溶液、0.10%甲酸溶液、5 mmol/L甲酸铵溶液、5 mmol/L甲酸铵-0.02%甲酸溶液4种不同的水相流动相对检测效果的影响。结果表明,水相流动相中引入铵离子后,各金属离子所形成的团簇离子响应显著降低。相比于0.02%甲酸,使用0.10%甲酸可使各离子色谱峰形更尖锐,但色谱保留更弱,质谱响应也更弱。因此,选择0.02%甲酸作为水相流动相。

      本实验还比较了Ultimate Hilic amide、ChromCore Hilic amide、ChromCore Hilic diol 3款色谱柱的洗脱效果。在相同的流动相下,各金属离子在ChromCore Hilic amide色谱柱无色谱峰,在ChromCore Hilic diol色谱柱色谱峰展宽且响应显著减弱,表明这2款色谱柱与金属离子有较强的相互作用,难以有效洗脱。Ultimate Hilic amide色谱柱对金属离子有较好的保留且峰形尖锐,可以减少溶液中基质对各离子检测的影响,但无法分离各离子。综合考虑,最终采用 Ultimate Hilic amide色谱柱,各定量离子对提取离子色谱图示于图2

    • 通过离心对样品进行前处理,并在上机溶液中加入10 µL甲酸,有利于金属离子的稳定。由于水、10%乙醇、20%乙醇、50%乙醇、4%乙酸食品模拟物上机溶液与用1%甲酸配制的标准溶液溶剂效应无明显差别,因此,这些模拟物均采用混合标准工作液1作为定量工作液。95%乙醇食品模拟物上机溶液与1%甲酸配制的标准溶液溶剂效应有明显差别(相同浓度下,Cu2+在95%乙醇食品模拟物上机溶液的响应比在1%甲酸配制的标准溶液的响应下降了约30%),因此,采用混合标准工作液2作为定量工作液。

    • 对1.3节配制的标准溶液进行分析,以目标物浓度为横坐标,峰面积为纵坐标绘制工作曲线,各离子的工作曲线和相关系数列于表2。可见,各离子工作曲线的相关系数(r2)均高于0.995,仪器检出限(S/N≥3)在20~80 μg/L之间。仪器定量限(S/N≥10)为工作曲线的最低浓度点,对应的方法定量限为加标实验的最低浓度,结果列于表3

    • 取食品接触塑料样品,分别使用水、4%乙酸、10%乙醇、20%乙醇、50%乙醇、95%乙醇食品模拟物进行迁移实验,向迁移液中加入低、中、高3个浓度水平的目标物,按1.4.2节处理后测定,每个水平重复6次,计算回收率和相对标准偏差(RSD),结果列于表3。可见,方法的回收率为88.6%~115%,RSD为0.3%~6.1%。

    • 本实验测试了24批次食品接触塑料制品的迁移液。在1份聚乙烯(PE)树脂迁移液中检出Zn2+、Cu2+离子,在1份PE垫片迁移液中检出Zn2+、Mn2+离子,在2份PET瓶样品迁移液中检出Mn2+离子。检出量均低于方法定量限,低于现行食品安全国家标准[1]对这些元素的迁移限值。

    • 本研究建立了LC-QTOF MS法测定食品接触塑料中6种金属离子迁移量,并比较了在不同流动相添加物条件下形成的团簇离子,利用金属离子可与乙腈、甲酸形成稳定团簇离子的性质,优化了液相色谱流动相等条件。同时,利用本方法在实际食品接触塑料制品迁移液中检出了Zn2+、Cu2+、Mn2+离子。本方法可直接检测高乙醇比例溶液中的金属离子,用于食品接触塑料中钴、铜、锰、锌元素迁移量的合规性筛查,对于食品接触塑料中未知风险物质的分析有较好的参考价值。

    参考文献 (21)

目录

/

返回文章