HPLC-MS/MS联用技术定量测定人血浆中氢可酮

上一篇

下一篇

郝光涛, 曲恒燕, 李媛媛, 朱力军, 马蒙, 刘泽源. 2011: HPLC-MS/MS联用技术定量测定人血浆中氢可酮, 质谱学报, 32(4): 252-256.
引用本文: 郝光涛, 曲恒燕, 李媛媛, 朱力军, 马蒙, 刘泽源. 2011: HPLC-MS/MS联用技术定量测定人血浆中氢可酮, 质谱学报, 32(4): 252-256.
HAO Guang-tao, QU Heng-yan, LI Yuan-yuan, ZHU Li-jun, MA Meng, LIU Ze-yuan. 2011: Determination of Hydrocodone in Human Plasma by High Performance Liquid Chromatography Coupled with Tandem Mass Spectrometry, Journal of Chinese Mass Spectrometry Society, 32(4): 252-256.
Citation: HAO Guang-tao, QU Heng-yan, LI Yuan-yuan, ZHU Li-jun, MA Meng, LIU Ze-yuan. 2011: Determination of Hydrocodone in Human Plasma by High Performance Liquid Chromatography Coupled with Tandem Mass Spectrometry, Journal of Chinese Mass Spectrometry Society, 32(4): 252-256.

HPLC-MS/MS联用技术定量测定人血浆中氢可酮

Determination of Hydrocodone in Human Plasma by High Performance Liquid Chromatography Coupled with Tandem Mass Spectrometry

  • 摘要: 建立HPLC-MS/MS方法定量测定人血浆中氢可酮浓度.以地西泮为内标,采用甲醇-0.05%甲酸水溶液为流动相进行梯度洗脱,以Agilent-C18(2.1×50 mm×3.5 μm)色谱柱为分析柱,通过电喷雾离子源( ESI),以正离子多反应监测(MRM)方式进行检测.用于定量分析的离子对分别为m/z 300.2→199.1(氢可酮)和m/z 285.0→193.0(地西泮,内标).氢可酮线性范围为0.5~50μg/l,定量下限为0.5 μg/L(n=6),日内、日间精密度的RSD均小于15%,平均回收率大于75%.本方法专属性强、样品处理简便、灵敏度高,适用于氢可酮临床药动学研究.
  • 加载中
  • 加载中
计量
  • 文章访问数:  466
  • HTML全文浏览数:  15
  • PDF下载数:  18
  • 施引文献:  0
出版历程
  • 刊出日期:  2011-08-28

HPLC-MS/MS联用技术定量测定人血浆中氢可酮

  • 军事医学科学院附属医院药理室,北京,100071
  • 蚌埠医学院,安徽蚌埠,233030

摘要: 建立HPLC-MS/MS方法定量测定人血浆中氢可酮浓度.以地西泮为内标,采用甲醇-0.05%甲酸水溶液为流动相进行梯度洗脱,以Agilent-C18(2.1×50 mm×3.5 μm)色谱柱为分析柱,通过电喷雾离子源( ESI),以正离子多反应监测(MRM)方式进行检测.用于定量分析的离子对分别为m/z 300.2→199.1(氢可酮)和m/z 285.0→193.0(地西泮,内标).氢可酮线性范围为0.5~50μg/l,定量下限为0.5 μg/L(n=6),日内、日间精密度的RSD均小于15%,平均回收率大于75%.本方法专属性强、样品处理简便、灵敏度高,适用于氢可酮临床药动学研究.

English Abstract

参考文献 (0)

目录

/

返回文章