HPLC-MS/MS联用技术定量测定人血浆中恩替卡韦

上一篇

下一篇

郝光涛, 李媛媛, 何世学, 陈刚, 高洪志, 刘泽源. 2010: HPLC-MS/MS联用技术定量测定人血浆中恩替卡韦, 质谱学报, 31(4): 252-256.
引用本文: 郝光涛, 李媛媛, 何世学, 陈刚, 高洪志, 刘泽源. 2010: HPLC-MS/MS联用技术定量测定人血浆中恩替卡韦, 质谱学报, 31(4): 252-256.
HAO Guang-tao, LI Yuan-yuan, HE Shi-xue, CHEN Gang, GAO Hong-zhi, LIU Ze-yuan. 2010: Quantitative Determination of Entecavir in Human Plasma by HPLC-MS/MS, Journal of Chinese Mass Spectrometry Society, 31(4): 252-256.
Citation: HAO Guang-tao, LI Yuan-yuan, HE Shi-xue, CHEN Gang, GAO Hong-zhi, LIU Ze-yuan. 2010: Quantitative Determination of Entecavir in Human Plasma by HPLC-MS/MS, Journal of Chinese Mass Spectrometry Society, 31(4): 252-256.

HPLC-MS/MS联用技术定量测定人血浆中恩替卡韦

Quantitative Determination of Entecavir in Human Plasma by HPLC-MS/MS

  • 摘要: 建立HPLC-MS/MS联用方法定量测定人血浆中恩替卡韦浓度.以地西泮为内标,甲醇为有机相,甲醇-水为(5 mmol·L-1碳酸氢铵)梯度洗脱流动相,Waters-Eterra MS-C18(2.1×50 mm×5μm)色谱柱为分析柱,通过电喷雾离子源(ESI),以正离子多反应监测(MRM)方式检测.用于定量分析的离子对分别为m/z 278.2→152.1(恩替卡韦)和m/z 285.0→193.0(地西泮,内标).慰替卡韦的线性范围为0.05~20μg·L-1,定量下限为0.05μg·L-1(n=6).日内、日间精密度的RSD<15%,平均回收率>75%.
  • 加载中
  • 加载中
计量
  • 文章访问数:  431
  • HTML全文浏览数:  19
  • PDF下载数:  49
  • 施引文献:  0
出版历程
  • 刊出日期:  2010-08-28

HPLC-MS/MS联用技术定量测定人血浆中恩替卡韦

  • 军事医学科学院附属医院药理室,北京,100071
  • 哈励逊国际和平医院,河北,衡水,053000

摘要: 建立HPLC-MS/MS联用方法定量测定人血浆中恩替卡韦浓度.以地西泮为内标,甲醇为有机相,甲醇-水为(5 mmol·L-1碳酸氢铵)梯度洗脱流动相,Waters-Eterra MS-C18(2.1×50 mm×5μm)色谱柱为分析柱,通过电喷雾离子源(ESI),以正离子多反应监测(MRM)方式检测.用于定量分析的离子对分别为m/z 278.2→152.1(恩替卡韦)和m/z 285.0→193.0(地西泮,内标).慰替卡韦的线性范围为0.05~20μg·L-1,定量下限为0.05μg·L-1(n=6).日内、日间精密度的RSD<15%,平均回收率>75%.