  • 摘要: 在系统运行与不运行状态下,线路绝缘子因高压脉冲而产生闪络和损伤现象的研究结果显示,脉冲干扰和系统工作电压的共同作用将对电力系统带来灾难性的威胁.而在电力系统中,高压变压器是非常重要并且昂贵的设备.本文给出了一些针对变压器在脉冲干扰和系统工作电压共同作用时的试验方法.
  • 加载中
  • 加载中
计量
  • 文章访问数:  331
  • HTML全文浏览数:  327
  • PDF下载数:  1
  • 施引文献:  0
出版历程
  • 刊出日期:  2019-01-01

电力系统运行状态下抗高压脉冲干扰评估

  • 俄罗斯科学院 联合高温研究所,莫斯科,125412
  • 西安交通大学 电力设备电气绝缘国家重点实验室,西安,710049

摘要: 在系统运行与不运行状态下,线路绝缘子因高压脉冲而产生闪络和损伤现象的研究结果显示,脉冲干扰和系统工作电压的共同作用将对电力系统带来灾难性的威胁.而在电力系统中,高压变压器是非常重要并且昂贵的设备.本文给出了一些针对变压器在脉冲干扰和系统工作电压共同作用时的试验方法.