含三维复杂工程细缝金属腔的电磁屏蔽效能评估

上一篇

下一篇

方明江, 刘强, 闫丽萍, 赵翔, 周海京. 2018: 含三维复杂工程细缝金属腔的电磁屏蔽效能评估, 强激光与粒子束, 30(7): 80-84. doi: 10.11884/HPLPB201830.180047
引用本文: 方明江, 刘强, 闫丽萍, 赵翔, 周海京. 2018: 含三维复杂工程细缝金属腔的电磁屏蔽效能评估, 强激光与粒子束, 30(7): 80-84. doi: 10.11884/HPLPB201830.180047
Fang Mingjiang, Liu Qiang, Yan Liping, Zhao Xiang, Zhou Haijing. 2018: Evaluation of electromagnetic shielding effectiveness for metallic enclosure with three-dimensional complex thin slots, High Power Lase and Particle Beams, 30(7): 80-84. doi: 10.11884/HPLPB201830.180047
Citation: Fang Mingjiang, Liu Qiang, Yan Liping, Zhao Xiang, Zhou Haijing. 2018: Evaluation of electromagnetic shielding effectiveness for metallic enclosure with three-dimensional complex thin slots, High Power Lase and Particle Beams, 30(7): 80-84. doi: 10.11884/HPLPB201830.180047

含三维复杂工程细缝金属腔的电磁屏蔽效能评估

Evaluation of electromagnetic shielding effectiveness for metallic enclosure with three-dimensional complex thin slots

  • 摘要: 复杂工程细缝为金属腔电磁屏蔽效能的评估带来了挑战.采用时域有限差分(FDTD)法结合环路(CP)法,在不改变原有粗网格剖分的基础上,实现了对三维复杂细缝结构金属腔电磁屏蔽效能的快速计算.提出复杂工程细缝的等效模型,提高了复杂细缝结构的CP编程和计算效率,计算结果与采用精细网格剖分的传统FDTD(fine-FDTD)计算结果吻合很好,验证了等效模型的有效性.在此基础上,分析了两种开有典型工程细缝金属腔在0~3 GHz内的电磁屏蔽效能,计算结果与fine-FDTD算法结果吻合很好,且计算效率大大提高.
  • 加载中
  • 加载中
计量
  • 文章访问数:  151
  • HTML全文浏览数:  103
  • PDF下载数:  5
  • 施引文献:  0
出版历程
  • 刊出日期:  2018-07-30

含三维复杂工程细缝金属腔的电磁屏蔽效能评估

  • 四川大学 电子信息学院,成都,610065
  • 北京应用物理与计算数学研究所,北京,100088

摘要: 复杂工程细缝为金属腔电磁屏蔽效能的评估带来了挑战.采用时域有限差分(FDTD)法结合环路(CP)法,在不改变原有粗网格剖分的基础上,实现了对三维复杂细缝结构金属腔电磁屏蔽效能的快速计算.提出复杂工程细缝的等效模型,提高了复杂细缝结构的CP编程和计算效率,计算结果与采用精细网格剖分的传统FDTD(fine-FDTD)计算结果吻合很好,验证了等效模型的有效性.在此基础上,分析了两种开有典型工程细缝金属腔在0~3 GHz内的电磁屏蔽效能,计算结果与fine-FDTD算法结果吻合很好,且计算效率大大提高.