  • 摘要: 研制了一种基于微通道板的超快脉冲中子探测器,对其γ射线灵敏度进行了理论和实验研究.建立了探测器的γ射线灵敏度理论计算模型,利用蒙特卡罗方法模拟计算了不同能量γ射线在不同厚度聚乙烯靶中产生的出射电子能谱和出射角度分布,并结合经验公式计算了单个电子在微通道板(MCP)孔道中产生的二次电子产额,最后得到了探测器的γ射线灵敏度,结果表明当聚乙烯靶厚度大于某一值时,γ射线灵敏度基本相同.利用西北核技术研究所的标准γ射线放射源对探测器的γ射线灵敏度进行了实验标定,实验结果与理论计算结果一致.
  • 加载中
  • 加载中
计量
  • 文章访问数:  341
  • HTML全文浏览数:  265
  • PDF下载数:  10
  • 施引文献:  0
出版历程
  • 刊出日期:  2018-04-30

基于微通道板的中子探测器γ射线灵敏度

  • 西北核技术研究所,西安710024;强脉冲辐射环境模拟与效应国家重点实验室,西安710024
  • 西北核技术研究所,西安,710024

摘要: 研制了一种基于微通道板的超快脉冲中子探测器,对其γ射线灵敏度进行了理论和实验研究.建立了探测器的γ射线灵敏度理论计算模型,利用蒙特卡罗方法模拟计算了不同能量γ射线在不同厚度聚乙烯靶中产生的出射电子能谱和出射角度分布,并结合经验公式计算了单个电子在微通道板(MCP)孔道中产生的二次电子产额,最后得到了探测器的γ射线灵敏度,结果表明当聚乙烯靶厚度大于某一值时,γ射线灵敏度基本相同.利用西北核技术研究所的标准γ射线放射源对探测器的γ射线灵敏度进行了实验标定,实验结果与理论计算结果一致.