MEMS 仿生矢量水听器微结构力学建模及实验验证

上一篇

下一篇

王续博, 张国军, 郭楠, 郭静, 张文栋. 2016: MEMS 仿生矢量水听器微结构力学建模及实验验证, 强激光与粒子束, null(2): 024101. doi: 10.11884/HPLPB201628.024101
引用本文: 王续博, 张国军, 郭楠, 郭静, 张文栋. 2016: MEMS 仿生矢量水听器微结构力学建模及实验验证, 强激光与粒子束, null(2): 024101. doi: 10.11884/HPLPB201628.024101
Wang Xubo, Zhang Guojun, Guo Nan, Guo Jing, Zhang Wendong. 2016: Modeling and experimental verification of microstructure of MEMS bionic vector hydrophone, High Power Lase and Particle Beams, null(2): 024101. doi: 10.11884/HPLPB201628.024101
Citation: Wang Xubo, Zhang Guojun, Guo Nan, Guo Jing, Zhang Wendong. 2016: Modeling and experimental verification of microstructure of MEMS bionic vector hydrophone, High Power Lase and Particle Beams, null(2): 024101. doi: 10.11884/HPLPB201628.024101

MEMS 仿生矢量水听器微结构力学建模及实验验证

Modeling and experimental verification of microstructure of MEMS bionic vector hydrophone

  • 摘要: MEMS 仿生矢量水听器是一种新型水声传感器,其工作性能决定于内部 MEMS 声电换能微结构的几何、材料及流体环境参数。为深入探讨该水听器的工作机理并提高其工作性能,针对其内部微结构通过合理的简化建立了相应的单自由度等效力学模型,并推导出理想流体环境下该微结构一阶固有频率与其几何、材料及流体环境参数间的解析表达式。在此基础上,推导出现有水听器微结构的一阶固有频率,并搭建实验平台进行验证,实验结果表明理论值与实验值间的相对误差低于5%,从而验证了该力学模型的有效性,为水听器的设计及优化提供了理论基础和参考依据,同时也为具有类似结构的传感器的性能分析奠定了基础。
  • 加载中
  • 加载中
计量
  • 文章访问数:  450
  • HTML全文浏览数:  187
  • PDF下载数:  49
  • 施引文献:  0
出版历程
  • 刊出日期:  2016-02-28

MEMS 仿生矢量水听器微结构力学建模及实验验证

  • 中北大学 电子测试技术重点实验室,太原 030051; 中北大学 仪器科学与动态测试教育部重点实验室,太原 030051
  • 中北大学 仪器科学与动态测试教育部重点实验室,太原,030051

摘要: MEMS 仿生矢量水听器是一种新型水声传感器,其工作性能决定于内部 MEMS 声电换能微结构的几何、材料及流体环境参数。为深入探讨该水听器的工作机理并提高其工作性能,针对其内部微结构通过合理的简化建立了相应的单自由度等效力学模型,并推导出理想流体环境下该微结构一阶固有频率与其几何、材料及流体环境参数间的解析表达式。在此基础上,推导出现有水听器微结构的一阶固有频率,并搭建实验平台进行验证,实验结果表明理论值与实验值间的相对误差低于5%,从而验证了该力学模型的有效性,为水听器的设计及优化提供了理论基础和参考依据,同时也为具有类似结构的传感器的性能分析奠定了基础。