Lattice considerations for the spectrometry ring (SRing) of the HIAF project

  • 摘要: 为了精确测量短寿命原子核质量,提出了在强流重离子加速器装置(HIAF)上建造高精度环形质量谱仪SRing.SRing长188.7 m,最大设计磁刚度为13 T·m,主要由磁聚焦结构、注入系统、引出系统、随机冷却以及探测系统等组成.SRing将运行在等时性模式和收集模式下用于短寿命原子核质量的精确测量和放射性次级束流收集并纯化.详细介绍了SRing的线性光学设计,并给出两种模式下的光学设计、注入及引出系统的设计等,设计参数优化完毕后,机器测量精度有望提高到106.
  • 加载中
  • 加载中
计量
  • 文章访问数:  355
  • HTML全文浏览数:  158
  • PDF下载数:  9
  • 施引文献:  0
出版历程
  • 刊出日期:  2014-05-30

HIAF中环形质量谱仪SRing的线性设计

  • 中国科学院近代物理研究所,兰州730000;中国科学院大学,北京100039
  • 中国科学院近代物理研究所,兰州,730000

摘要: 为了精确测量短寿命原子核质量,提出了在强流重离子加速器装置(HIAF)上建造高精度环形质量谱仪SRing.SRing长188.7 m,最大设计磁刚度为13 T·m,主要由磁聚焦结构、注入系统、引出系统、随机冷却以及探测系统等组成.SRing将运行在等时性模式和收集模式下用于短寿命原子核质量的精确测量和放射性次级束流收集并纯化.详细介绍了SRing的线性光学设计,并给出两种模式下的光学设计、注入及引出系统的设计等,设计参数优化完毕后,机器测量精度有望提高到106.