  • 摘要: 基于束流沉积法测量回旋加速器内部束流参数将在束测探头上产生感生放射性污染,从而对加速器调束工作人员带来不必要的辐射危害.采用AGM-6型γ监测仪对探头感生放射性进行在线测量,通过测量不同半径处探头受辐射后的空气比释动能率,间接反映探头感生放射性的强弱和危害.研究结果表明,在束流调试实验中,应尽量降低馈入高频的占空比;探头测量后冷却2~3 h取出,则不需要考虑测量探头辐照后的残留感生放射性的危害.
  • 加载中
  • 加载中
计量
  • 文章访问数:  588
  • HTML全文浏览数:  291
  • PDF下载数:  21
  • 施引文献:  0
出版历程
  • 刊出日期:  2013-07-30

回旋加速器束测探头感生放射性实验研究

  • 中国工程物理研究院流体物理研究所,四川绵阳,621900

摘要: 基于束流沉积法测量回旋加速器内部束流参数将在束测探头上产生感生放射性污染,从而对加速器调束工作人员带来不必要的辐射危害.采用AGM-6型γ监测仪对探头感生放射性进行在线测量,通过测量不同半径处探头受辐射后的空气比释动能率,间接反映探头感生放射性的强弱和危害.研究结果表明,在束流调试实验中,应尽量降低馈入高频的占空比;探头测量后冷却2~3 h取出,则不需要考虑测量探头辐照后的残留感生放射性的危害.