DPF-300脉冲X射线源同步触发系统研制

上一篇

下一篇

梁天学, 关颖, 蒯斌, 丛培天, 林东生, 韩福斌, 杨善潮, 张众. 2007: DPF-300脉冲X射线源同步触发系统研制, 强激光与粒子束, 19(1): 151-154.
引用本文: 梁天学, 关颖, 蒯斌, 丛培天, 林东生, 韩福斌, 杨善潮, 张众. 2007: DPF-300脉冲X射线源同步触发系统研制, 强激光与粒子束, 19(1): 151-154.
LIANG Tian-xue, GUAN Ying, KUAI Bin, CONG Pei-tian, LIN Dong-sheng, HAN Fu-bin, YANG Shan-chao, ZHANG Zhong. 2007: Development of synchronous trigger system for DPF-300 pulsed X-ray source, High Power Lase and Particle Beams, 19(1): 151-154.
Citation: LIANG Tian-xue, GUAN Ying, KUAI Bin, CONG Pei-tian, LIN Dong-sheng, HAN Fu-bin, YANG Shan-chao, ZHANG Zhong. 2007: Development of synchronous trigger system for DPF-300 pulsed X-ray source, High Power Lase and Particle Beams, 19(1): 151-154.

DPF-300脉冲X射线源同步触发系统研制

Development of synchronous trigger system for DPF-300 pulsed X-ray source

  • 摘要: DPF-300脉冲X射线源的同步触发系统采用三级触发:第一级由初级脉冲产生器触发氢闸流管;第二级由氢闸流管输出脉冲触发多路触发开关;第三级由多路触发开关和触发箱组成,触发主放电场畸变开关.该触发系统中多路触发开关产生负极性脉冲信号,通过耦合电容,到达开关的触发脉冲上升沿,约为40 ns,脉冲半高宽约60 ns,上升陡度大于0.67 kV/ns.能够同时触发40个同轴型场畸变开关,电压工作范围20~40 kV,不同发次触发箱输出的触发脉冲信号时间分散性小于4 ns,同一发次不同开关的放电时间分散性小于20 ns.在工作电压20 kV,主放电开关充0.115 Mpa氮气时,整机负载电流达到约1 MA.
  • 加载中
  • 加载中
计量
  • 文章访问数:  289
  • HTML全文浏览数:  26
  • PDF下载数:  27
  • 施引文献:  0
出版历程
  • 刊出日期:  2007-01-30

DPF-300脉冲X射线源同步触发系统研制

  • 西北核技术研究所,西安,710024

摘要: DPF-300脉冲X射线源的同步触发系统采用三级触发:第一级由初级脉冲产生器触发氢闸流管;第二级由氢闸流管输出脉冲触发多路触发开关;第三级由多路触发开关和触发箱组成,触发主放电场畸变开关.该触发系统中多路触发开关产生负极性脉冲信号,通过耦合电容,到达开关的触发脉冲上升沿,约为40 ns,脉冲半高宽约60 ns,上升陡度大于0.67 kV/ns.能够同时触发40个同轴型场畸变开关,电压工作范围20~40 kV,不同发次触发箱输出的触发脉冲信号时间分散性小于4 ns,同一发次不同开关的放电时间分散性小于20 ns.在工作电压20 kV,主放电开关充0.115 Mpa氮气时,整机负载电流达到约1 MA.

English Abstract