电荷收集法测量低温等离子体密度

Measurement of low-temperature plasma density with charge collectors

  • 摘要: 利用电荷收集法,在正(135 V)、负(-117 V)偏置和低真空背景(0.5 Pa)三种不同收集条件下,测量了用于等离子体断路开关的电缆等离子体枪产生的低温等离子体的密度和漂移速率,测量值分别为8.3×1014,1.2×1015,4.8×1014cm-3;2.5,2.0 cm·μs-1.测量结果表明:三种收集条件下测得的等离子体漂移速率相近;在相同测量点处,负偏置收集条件下测得的等离子体密度大于正偏置和低真空背景收集条件下的测量值,而低真空背景收集条件下的测量值最小.
  • 加载中
  • 加载中
计量
  • 文章访问数:  345
  • HTML全文浏览数:  22
  • PDF下载数:  39
  • 施引文献:  0
出版历程
  • 刊出日期:  2005-02-28

电荷收集法测量低温等离子体密度

  • 西北核技术研究所,陕西,西安,710024

摘要: 利用电荷收集法,在正(135 V)、负(-117 V)偏置和低真空背景(0.5 Pa)三种不同收集条件下,测量了用于等离子体断路开关的电缆等离子体枪产生的低温等离子体的密度和漂移速率,测量值分别为8.3×1014,1.2×1015,4.8×1014cm-3;2.5,2.0 cm·μs-1.测量结果表明:三种收集条件下测得的等离子体漂移速率相近;在相同测量点处,负偏置收集条件下测得的等离子体密度大于正偏置和低真空背景收集条件下的测量值,而低真空背景收集条件下的测量值最小.