通信波长频率一致纠缠光源的频谱测量

上一篇

下一篇

王盟盟, 权润爱, 邰朝阳, 侯飞雁, 刘涛, 张首刚, 董瑞芳. 2014: 通信波长频率一致纠缠光源的频谱测量, 物理学报, null(19): 194206. doi: 10.7498/aps.63.194206
引用本文: 王盟盟, 权润爱, 邰朝阳, 侯飞雁, 刘涛, 张首刚, 董瑞芳. 2014: 通信波长频率一致纠缠光源的频谱测量, 物理学报, null(19): 194206. doi: 10.7498/aps.63.194206
Wang Meng-Meng, Quan Run-Ai, Tai Zhao-Yang, Hou Fei-Yan, Liu Tao, Zhang Shou-Gang, Dong Rui-Fang. 2014: Measurement of the sp ectral prop erties of the coincident-frequency entangled biphoton state at optical communication wavelength, Acta Physica Sinica, null(19): 194206. doi: 10.7498/aps.63.194206
Citation: Wang Meng-Meng, Quan Run-Ai, Tai Zhao-Yang, Hou Fei-Yan, Liu Tao, Zhang Shou-Gang, Dong Rui-Fang. 2014: Measurement of the sp ectral prop erties of the coincident-frequency entangled biphoton state at optical communication wavelength, Acta Physica Sinica, null(19): 194206. doi: 10.7498/aps.63.194206

通信波长频率一致纠缠光源的频谱测量

Measurement of the sp ectral prop erties of the coincident-frequency entangled biphoton state at optical communication wavelength

  • 摘要: 本文利用光栅单色仪实现了对超短脉冲抽运周期极化磷酸氧钛钾晶体产生的通信波长频率一致纠缠光子源的频谱特性分析.测量到双光子的联合频谱呈正关联分布,为频率一致纠缠光源.信号光、闲置光中心波长分别为1574.4 nm和1574.9 nm,频谱宽度分别为35.3 nm和37.6 nm,双光子符合包络宽度约为3 nm.根据单光子频谱宽度与双光子符合包络宽度的比值可以得到双光子的频率纠缠参量R约为12,表征了信号光子与闲置光子之间具有较高的频率纠缠度.
  • 加载中
  • 加载中
计量
  • 文章访问数:  347
  • HTML全文浏览数:  74
  • PDF下载数:  0
  • 施引文献:  0
出版历程
  • 刊出日期:  2014-10-15

通信波长频率一致纠缠光源的频谱测量

  • 中国科学院国家授时中心,中国科学院时间频率基准重点实验室,西安 710600; 中国科学院大学,北京 100049
  • 中国科学院国家授时中心,中国科学院时间频率基准重点实验室,西安 710600

摘要: 本文利用光栅单色仪实现了对超短脉冲抽运周期极化磷酸氧钛钾晶体产生的通信波长频率一致纠缠光子源的频谱特性分析.测量到双光子的联合频谱呈正关联分布,为频率一致纠缠光源.信号光、闲置光中心波长分别为1574.4 nm和1574.9 nm,频谱宽度分别为35.3 nm和37.6 nm,双光子符合包络宽度约为3 nm.根据单光子频谱宽度与双光子符合包络宽度的比值可以得到双光子的频率纠缠参量R约为12,表征了信号光子与闲置光子之间具有较高的频率纠缠度.