[1] Elisabeth S, Jasper H, Michael P, et al. Real-time trace detection of security-relevant compounds in complex matrices by thermal desorption-single photon ionization-ion trap mass spectrometry (TD-SPI-ITMS)[J]. Analytical and Bioanalytical Chemistry,2009,395(6):1795−1807 doi: 10.1007/s00216-009-2916-4
[2] Nielen M W F, Hooijerink H, Zomer P, Mol J G J. Desorption electrospray ionization mass spectrometry in the analysis of chemical food contaminants in food[J]. Trends in Analytical Chemistry,2011,30(2):165−180 doi: 10.1016/j.trac.2010.11.006
[3] Takada Y, Nagano H, Suga M, et al. Detection of military explosives by atmosphere pressure chemical ionization mass spectrometry with counter-flow introduction[J]. Propellants, Explosives, Pyrotechnics,2002,27(4):224−228 doi: 10.1002/1521-4087(200209)27:4<224::AID-PREP224>3.0.CO;2-V
[4] Peter H D. Quadrupole mass spectrometry and its applications[M]. New York: American Institute of Physics, 1976
[5] Dong Meng, Sun Wenjun, Wu Chengyao, et al. A UHV standard with option to be used as partial pressure standard[J]. Metrologia,2020,57(2):17−25
[6] Alper E, Rifat K. Remarks concerning about the characteristics of the extractor vacuum gauge and the Quadrupole Mass Spectrometer[J]. Measurement,2019,131:269−276 doi: 10.1016/j.measurement.2018.08.043
[7] Elkatmis A, Kangi R, Becker U, et al. Time stability characterization of quadrupole mass spectrometers[J]. Measurement,2020,165:108−143
[8] Ma F M, Taylor S. Simulation of ion trajectories through the mass filter of a quadrupole mass spectrometer[J]. IEE Proceedings-Science, Measurement and Technology,1996,143(1):71−76 doi: 10.1049/ip-smt:19960128
[9] Forbes M W, Sharifi M, Croley T, et al. Simulation of ion trajectories in a quadrupole ion trap- a comparison of three simulation programs[J]. Journal of Mass Spectrometry,1999,34(12):1219−1239 doi: 10.1002/(SICI)1096-9888(199912)34:12<1219::AID-JMS897>3.0.CO;2-L
[10] 张志良, 孙越强, 李永平, 等. 基于COMSOL的星载四极质谱仪仿真分析[J]. 真空科学与技术学报,2022,42(7):517−524 doi: 10.13922/j.cnki.cjvst.202201013 ZHANG Zhiliang, SUN Yueqiang, LI Yongping, et al. Simulation and analysis of spaceborne quadrupole mass spectrometer based on COMSOL[J]. Chinese Journal of Vacuum Science and Technology,2022,42(7):517−524 (in Chinese) doi: 10.13922/j.cnki.cjvst.202201013
[11] 于炳琪. 污染对四极质谱计性能的影响[J]. 真空,1999(6):15−19 doi: 10.13385/j.cnki.vacuum.1999.06.004 YU Bingqi. Effect of contamination on performance of quadrupole mass spectrometer[J]. Vacuum,1999(6):15−19 (in Chinese) doi: 10.13385/j.cnki.vacuum.1999.06.004