[1] |
Kendall B R F, Drubetsky E. Cold cathode gauges for ultrahigh vacuum measurements[J]. Journal of Vacuum Science & Technology A,1997,15(3):740−746 doi: 10.1116/1.580813
|
[2] |
Peacock R N, Peacock N T, Hauschulz D S. Comparison of hot cathode and cold cathode ionization gauges[J]. Journal of Vacuum Science & Technology A,1991,9(3):1977−1985 doi: 10.1116/1.577439
|
[3] |
Kendall B R F. Ionization gauge errors at low pressures[J]. Journal of Vacuum Science & Technology A,1999,17(4):2041−2049 doi: 10.1116/1.581912
|
[4] |
Chae J, Stark B H, Najafi K. A micromachined pirani gauge with dual heat sinks[J]. IEEE Transactions on Advanced Packaging,2005,28(4):619−625 doi: 10.1109/TADVP.2005.858316
|
[5] |
Wilfert S, Edelmann C. Miniaturized vacuum gauges[J]. Journal of Vacuum Science & Technology A,2004,22(2):309−320
|
[6] |
王呈祥, 韩晓东, 李得天, 等. MEMS型电容薄膜真空计的关键技术研究进展[J]. 真空科学与技术学报,2019,39(1):24−33(in Chinese)
Wang C X, Han X D, Li D T, et al. Latest advance in fabrication technologies of MEMS-type capacitance diaphragm gauge[J]. Chinese Journal of Vacuum Science and Technology,2019,39(1):24−33
|
[7] |
Green S R, Malhotra R, Gianchandani Y B. Sub-torr chip-scale sputter-ion pump based on a penning cell array architecture[J]. Journal of Microelectromechanical Systems,2013,22(2):309−317 doi: 10.1109/JMEMS.2012.2221159
|
[8] |
Penning F M. Ein neues manometer für niedrige gasdrucke, insbesondere zwischen 10−3 und 10−5 mm[J]. Physica, 1937, 4(2): 71−75
|
[9] |
蔡敏, 李得天, 成永军, 等. 场发射冷阴极电离规的研究进展[J]. 真空科学与技术学报,2011,31(6):732−738(in Chinese) doi: 10.3969/j.issn.1672-7126.2011.06.16
Cai M, Li D T, Cheng Y J, et al. Latest development of ionization gauges with field emitters[J]. Chinese Journal of Vacuum Science and Technology,2011,31(6):732−738 doi: 10.3969/j.issn.1672-7126.2011.06.16
|
[10] |
Kendall B R F, Drubetsky E. Compact wide-range cold-cathode gauges[J]. Journal of Vacuum Science & Technology A,2000,18(4):1724−1729
|
[11] |
李得天, 习振华, 王永军, 等. 真空测试计量技术及其航天应用[J]. 真空科学与技术学报,2021,41(9):795−816(in Chinese)
Li D T, Xi Z H, Wang Y J, et al. Vacuum metrology technology and its space application[J]. Chinese Journal of Vacuum Science and Technology,2021,41(9):795−816
|
[12] |
Grzebyk T, Górecka-Drzazga A. MEMS type ionization vacuum sensor[J]. Sensors and Actuators A: Physical,2016,246:148−155 doi: 10.1016/j.sna.2016.05.021
|
[13] |
Humphries Jr S, Hwang C S. Miniature penning ionization gauge for pulsed gas measurements[J]. Review of Scientific Instruments,1984,55(10):1663−1665 doi: 10.1063/1.1137637
|
[14] |
MKSinst. com. Mks 903 inverted magnetron cold cathode vacuum transducer[EB/OL]. https://www.mksinst.com/docs/UR/903.pdf
|
[15] |
Isoardi T, Ferretti A, Bonmassar L, et al. Modeling and simulation of sputter-ion pump performances[J]. Vacuum,2023,209:111792 doi: 10.1016/j.vacuum.2022.111792
|
[16] |
Deng S Y, Green S R, Gianchandani Y B. A 3D-printed miniature magnetron gauge for ultra-high vacuum environments[J]. Vacuum,2018,156:264−270 doi: 10.1016/j.vacuum.2018.07.039
|
[17] |
Haynes W M. CRC handbook of chemistry and physics (97th edition)[M]. Boca Raton: CRC Press, 2016
|
[18] |
Bryant P J, Longley W W Jr, Gosselin C M. Cold-cathode magnetron gauge characteristics[J]. Journal of Vacuum Science & Technology,1966,3(2):62−67 doi: 10.1116/1.1492454
|