[1] |
Yu X F, Dou R C, Qi F. Study on in situ mass spectrometry leak detection technique of working fluid in spacecraft electric propulsion system[J]. Vacuum,2024,8(226):111−116
|
[2] |
冯焱, 李得天. 四极质谱计在真空检漏中的应用[J]. 真空,2006,43(3):46−47 (in Chinese) doi: 10.3969/j.issn.1002-0322.2006.03.013
Feng Y, Li D T. Application of quadrupole mass spectrometry in vacuum leak detection[J]. Vacuum,2006,43(3):46−47 doi: 10.3969/j.issn.1002-0322.2006.03.013
|
[3] |
温永刚, 陈光奇, 陈联, 等. 四极质谱计在航天检漏技术中的应用[J]. 真空与低温,2008,14(4):223−226 (in Chinese) doi: 10.3969/j.issn.1006-7086.2008.04.009
Wen Y G, Chen G Q, Chen L, et al. Application of quadrupole mass spectrometry in aerospace leak detection technology[J]. Vacuum and Cryogenics,2008,14(4):223−226 doi: 10.3969/j.issn.1006-7086.2008.04.009
|
[4] |
闫荣鑫, 刘平, 冯琪, 等. 质谱分析系统航天器检漏研究[J]. 中国空间科学技术,2001,8(4):42−49 (in Chinese) doi: 10.3321/j.issn:1000-758X.2001.04.007
Yan R X, Liu P, Feng Q, et al. Study of spacecraft leakage detection by mass spectrometry analysis system[J]. China Space Science and Technology,2001,8(4):42−49 doi: 10.3321/j.issn:1000-758X.2001.04.007
|
[5] |
肖祥正, 闫荣鑫, 陈光峰, 等. 常压检漏的多种示漏气体分析仪的研制[J]. 真空与低温,1999,5(1):4−9 (in Chinese)
Xiao X Z, Yan R X, Chen G F, et al. Development of a multi-leakage gas analyser for atmospheric pressure leak detection[J]. Vacuum and Cryogenic,1999,5(1):4−9
|
[6] |
韩琰, 孙立臣, 王静涛, 等. 氙气与多种示漏气体漏率转换关系研究[J]. 真空,2023,60(3):67−71 (in Chinese)
Han Y, Sun L C, Wang J T, et al. Study on the relationship between xenon and leakage rate conversion of various leak indicating gases[J]. Vacuum,2023,60(3):67−71
|
[7] |
王星辉, 成永军, 董猛, 等. 基于四极质谱计质量歧视效应修正的材料CxHy放气率测试方法研究[J]. 真空科学与技术学报,2023,43(11):938−940 (in Chinese)
Wang X H, Cheng Y J, Dong M, et al. Research on measurement method of material CxHy outgassing rate based on the correction of mass discrimination effect of quadrupole mass spectrometer[J]. Chinese journal of vacuum science and technology,2023,43(11):938−940
|
[8] |
Chen X, Huang T B, Wang L G, et al. Real time calibration for ultrasensitive leak detecion[J]. Vacuum,2006,81(3):257−259 doi: 10.1016/j.vacuum.2005.11.074
|
[9] |
Chen X, Huang T B, Wang L G, et al. Ultrasensitive leak detection during ultrahigh vacuum evacuation by quadrupole mass spectrometer[J]. Jorunal of Vacuum Science & Technology A,2006,24(1):91−94
|
[10] |
Bai G Y, Hu X D, Liao X D, et al. Optimization and testing of a Mass Spectrometer Leak Detection (MSLD) system[J]. Materials Evaluation,2023,81(12):41−50 doi: 10.32548/10.32548/2023.me-04345
|
[11] |
Peters J L. An ultra-sensitive mass spectrometer leak detector and its application to vacuum technology[J]. Vacuum Technology Transactions,2013:94−96
|