The dissociative chemisorption of small molecules on metal surfaces represents an initial and often a rate-limiting step in heterogeneous catalytic processes [1]. A predictive understanding of dissociative adsorption at the atomic level is therefore highly desirable for establishing rational models of heterogeneous catalysis [2]. To this end, the synergic interplay between experiment and theory in the past decades has achieved great successes in describing small molecules with well-defined initial conditions reacting on well-structured single crystal metal surfaces in ultrahigh vacuum [3-5]. For example, the dissociative adsorption of the simplest H2 molecule on metal surfaces has been well studied. Theoretical models based on density functional theory (DFT) with reaction-specific parameters have successfully reproduced measured initial sticking coefficients of H2 on copper and platinum surfaces within chemical accuracy (1 kcal/mol) [6-11].
However, despite many efforts [12-21], our understanding on the dissociative chemisorption of a heavier molecule, namely HCl on Au(111), remains far from complete. The rotationally inelastic scattering of HCl from Au(111) was first experimentally examined in early 1990s [22]. Later, the vibrational energy transfer between HCl molecules and the Au(111) surface was suggested to involve an interesting turnaround from an adiabatic to a nonadiabatic mechanism as the surface temperature (Ts) increases [23-26]. More puzzlingly, the measured zero-coverage (initial) dissociative sticking probability (S0) of HCl on Au(111) as a function of translational energy [13] was found over two orders of magnitude lower than theoretical predictions based on quantum dynamics (QD) calculations on a six-dimensional DFT-based neural network (NN) potential energy surface (PES) within the frozen surface approximation [12]. Since then, molecular reaction dynamics calculations at different levels have been performed by several theoretical groups to attack this problem [14-20, 27]. For example, theory-experiment agreement has been improved by using more repulsive [15, 17, 27] or dispersion-corrected DFs [19] in on-the-fly ab initio molecular dynamics (AIMD) simulations [14, 19] or MD simulations on high-dimensional NN PESs with the non-frozen surface [15, 19, 20, 27], and taking electron-hole pair effects into account by an electronic friction model [15, 19, 27]. Combined with an improved analysis of experimental data [20], so far the best theory still overestimated experimental sticking probabilities by a factor of 2–7 at the highest incident energy and much more at lower energies [20]. Importantly, the origin of the large discrepancy between theory and experiment remains less clear. Additional and different experimental information on this system will be therefore highly useful.
To gain more insights into this puzzle, in this work, we repeat the experiment using a newly designed molecular beam-surface apparatus [28]. Our measured dissociative sticking probabilities agree well with previous experimental data at similar conditions. In addition, DFT calculations with different supercells and coverages show a decreased dissociation barrier at a lower coverage, which qualitatively explains the sharp change of the coverage/dose differential slope with the HCl dosage. This suggests a possible issue in previous simulations typically based on finite-coverages. Our results shed new light on this controversial problem and provide guidance for improving both experiments and theoretical models.
-
The experimental apparatus has been described in detail elsewhere [28]. Briefly, as shown in FIG. 1. the apparatus consists of a beam source chamber, two differentially pumping stages, and an UHV surface reaction chamber. The continuous molecular beam was generated by supersonic expansion through a temperature-controlled nozzle of 50 μm diameter. We used 4% HCl mixed with H2 and the nozzle temperature can be adjusted in the range of 300 K to 1413 K to ensure the incident energy (Ei) varying from 1.08 eV to 2.76 eV. The single-crystal Au(111) surface (purity 99.999%, orientation accuracy better than 0.1°, MaTeck) was cleaned by argon ion sputtering (3000 eV, 20 min) and annealed to 1000 K for 30 min before the adsorption experiment. The coverage of Cl atoms (
$ {\theta }_{\mathrm{C}\mathrm{l}} $ ) on the surface was detected using Auger electron spectroscopy (AES). The ratio of the peak heights of 181 eV (Cl) and 239 eV (Au) gives an estimate of the Cl-coverage [29]. We took the more accurate value (1.39×1015 cm−2·ML−1) [30, 31] for the areal number density of Cl atoms per monolayer (ML) on the unreconstructed Au(111) surface as suggested in Ref.[20].The experiment was carried out at Ts = 200 K. Our temperature programmed desorption (TPD) experiments of HCl dosed on Au(111) observe a large amount of physiosorbed HCl molecules at Ts < 200 K, which would cause an artificially larger coverage of Cl measured by AES than the actual chemisorption of HCl. On the other hand, the measured Cl coverage will decrease with the increasing Ts for a given HCl dose as the rate of H–Cl recombination increases faster than that of H–H recombination at higher Ts. Besides, if the surface temperature goes too high (Ts > 800 K), the Cl–Cl recombination will become appreciable. As a result, we choose Ts = 200 K for the experiment to minimize the influence of these effects simultaneously. We assume that the contribution of v > 1 of HCl molecules is negligible in the experiment, because the proportion of v = 0 is > 95% even at the highest nozzle temperature. Following the same procedure as Ref.[13], for each incidence energy, we performed an AES scan to get the Cl coverage on surface every time after reaching a certain dose. These Cl atoms adsorbed on the Au surface were subsequently removed by flash annealing the surface for 10 min at 1000 K. In this way, the Cl coverage was measured as a function of the initial HCl dose (
$ {D}_{\mathrm{H}\mathrm{C}\mathrm{l}} $ ) per ML at various incidence energies. Our results show a similar trend as observed in Refs. [20] and [32], from which a first-order kinetic model was used to fit the experimental data to get Ei-dependent dissociative sticking probabilities (S0) at zero coverage. -
DFT calculations in this work were performed with the Vienna Ab Initio Simulation Package (VASP) [33-34] and the revised Perdew-Burke-Ernzerhof (RPBE) [35] functional at the generalized gradient approximation (GGA) level, showing a relatively closer agreement to experiment. The projector augmented wave (PAW) method was applied to describe the electron-core interaction [36]. The kinetic energy in the plane wave basis set was truncated at 400 eV. The Au (111) surface was cleaved from the bulk structure to form a periodic slab with a thickness of four metal layers vertically separated by a vacuum of 16 Å. To determine how the Cl-coverage affects the HCl dissociation, we considered one HCl molecule in the 2 × 2, 3 × 3, and 5 × 5 supercells, respectively. In the largest 5 × 5 supercell, we also pre-covered the surface by one and two Cl atoms in addition to the impinging HCl molecule. The pre-adsorbed Cl atoms were placed in the unit-cell next to the one where the HCl molecule dissociates. This placement allows to inspect the influence of the pre-covered Cl atoms on the dissociation barrier, but does not introduce too strong repulsion. The top three Au layers and pre-adsorbed Cl atoms were relaxed during the optimization of transition states (TSs) by the climbing image-Nudged elastic band [37, 38] (CI-NEB) method. For different slab models, to properly sample the Brillouin zone at a converged level of accuracy, we ensured that the product of the number of k-points and the length of the lattice vector is more or less a constant. To this end, 11 × 11 × 1, 7 × 7 × 1, 5 × 5 × 1 Γ-centered k-points were used for the 2 × 2, 3 × 3, and 5 × 5 supercells, respectively.
-
FIG. 2 compares present and previous experimental initial sticking probabilities of HCl on Au(111) with a variety of theoretical results. It should be noted that previous experiments in Ref.[20] give an upper and a lower limit of S0 for each incident energy considering the uncertainty in estimating the HCl partial pressure and the temperature dependence of the coverage [20]. Encouragingly, our new experimental data fall into the range between the upper and lower bound. The energy threshold for observing a noticeable S0 (e.g., 10−3) is measured as ~1.30 eV, close to the previously reported value 1.35 eV. This represents a cross-validation for both sets of experimental data. On the other hand, theoretical results from different models are very diverse. Early six-dimensional (6D) quantum dynamics (QD) calculations on the frozen surface using Perdew-Wang 91 (PW91) [39] and RPBE functionals yielded very different results, due to their barrier height difference [12, 17]. This is confirmed by later quasi-classical trajectories (QCT) calculations showing that the more repulsive RPBE functional gives much lower S0 values, in relatively better agreement with experiment at low incident energies than other semi-local PW91 [12, 17] and PBE [15] functionals. A non-local SRP32-vdW functional with van der Waals correction predicts slightly higher reactivity than RPBE [19], whereas a RPBE-like meta-GGA functional, namely MS-RPBEl, is able to further lower the reactivity [20]. In particular, surface atom motion by either AIMD [19] or QCT with high-dimensional NN potentials [20, 27] and low-energy electron-hole pair (EHP) excitations [19, 36] by the local density friction approximation (LDFA) [40] were found to have minimal effects on the calculated S0 (not shown). However, even the lowest S0 curve predicted by MS-RPBEl still overestimates the current experimental data by a factor of 2–7 at the highest incidence energy [20].
Next, we turn to discuss possible reasons of the disagreement between theory and experiment. Experimentally, we notice in FIG. 3 (and its inset) that while the Cl coverage increases with the HCl dose, the incremental ratio decreases with increasing HCl dose, manifesting a decrease of the slope
${-}{\rm{d}}\ln\left(1-{\theta }_{\rm{Cl}}\right)/{\rm{d}}{D}_{\mathrm{HCl}}$ . This is consistent with the first-order kinetics which suggests an exponential growth of the adsorbate amount. However, the rapid change of the slope${-}{\rm{d}}\ln\left(1-{\theta }_{\rm{Cl}}\right)/{\rm{d}}{D}_{\mathrm{HCl}}$ requires more experimental data at low Cl-coverages to minimize the error when fitting to the first-order kinetic model. Unfortunately, due to the detection sensitivity limit of the AES, the near-zero coverage measurements (say < 0.06 ML) are extremely difficult. As a result, both current and previous experiments [20] have relied on these medium to high coverage data, which may lead to uncertainties when extrapolating the finite-coverage data to the zero-coverage limit and underestimate the S0 value as the$-{\rm{d}}\ln\left(1-\theta_{\rm{Cl}}\right)/{\rm{d}}D_{\rm{HCl}}$ slope becomes the highest when$ {\theta }_{\mathrm{C}\mathrm{l}} $ goes to zero.Given the limitation of experimental methods, we resort to theory for some qualitative insights on the coverage-dependent dissociation behavior. While the barrier heights predicted by earlier DFT calculations were found highly dependent on the DF, little attention has been paid to the coverage dependence of the barrier height. Indeed, earlier DFT calculations for HCl dissociation on Au(111) were typically based on a 2 × 2 or a 3 × 3 supercell, corresponding to 1/4 ML [12, 15, 17, 19, 41] or 1/9 ML [14, 16, 20, 27] respectively. For example, the PW91 functional with a 2 × 2 supercell predicted a dissociation barrier height (Eb) of 0.66 eV [41], which is too low compared with that of 0.76 eV by PBE with a 2 × 2 supercell [15], and 1.02 eV by RPBE with a 2 × 2 supercell [18], 0.91 eV by RPBE with a 3 × 3 supercell [14], respectively.
Using the relatively better RPBE functional, we calculate the coverage-dependent Eb which are shown in FIG. 4. Our present calculations in a 2 × 2 supercell with a tighter force convergence criterion reproduce reasonably well these results with Eb=1.10 eV. As the coverage decreases to 1/9 ML and 1/25 ML by using 3 × 3 and 5 × 5 supercells, the barrier height gradually drops to 1.03 eV and 0.91 eV. While this suggests an increase of Eb with coverage, the situation is somewhat artificial in the sense that HCl and all of its repeated images are dissociating at the same time [42]. We consider the more realistic HCl dissociation in the presence of pre-adsorbed Cl atoms, using the largest 5 × 5 supercell to minimize the repulsion between the dissociating HCl and its repeated images, as suggested by Ueta et al. who studied the coverage-dependent dissociation of CH4 on Pt(111) [42]. Either one or two Cl atoms were pre-adsorbed on the preferred hollow sites [18], as illustrated in FIG. 4. In these cases, the computed Eb values are 0.95 and 1.01 eV, again indicating an increase in Eb with the Cl-coverage. Note that to avoid including artificial repulsion between products, pre-covered Cl atoms were placed at least one lattice constant distant from each other. Our calculated results support that the dissociation probability should decrease with the increasing coverage, which is qualitatively consistent with the decrease of the slope in FIG. 2.
This finding may have important implications to the comparison between experimental and theoretical dissociative sticking probabilities for HCl on Au(111). On one hand, the lack of low-coverage measurements may render the experimentally derived zero-coverage S0 lower than the true value. This was not a problem in the experiments on the dissociative chemisorption of D2O [43] and CH4 [42], where the detection sensitivity of adsorbed species is much higher. On the other hand, existing theoretical models were all based on small supercells, corresponding to 1/9 or 1/4 ML. A larger supercell that mimics the quasi-zero-coverage condition would have a lower barrier height, thus resulting in even more facile dissociation. Apparently, more theoretical efforts are necessary to find reasonable reasons to lower the reactivity. It is worthwhile to use more advanced theory to describe the dissociation barrier height [44] and nonadiabatic effects [45, 46].
-
In summary, we have reinvestigated the dissociative adsorption of HCl on Au(111), one of the most puzzling gas-surface systems in which the disagreement between theory and experiment was surprisingly large. By measuring the Cl-coverage dependent dissociative ratio in a newly-designed experimental apparatus that can be rationalized by DFT predicted coverage-dependent barrier heights, we argue that a small amount of Cl adsorbates on the surface will largely change the dissociation barrier of HCl, making the standard extrapolation method for the zero-coverage S0 less accurate. Taking this factor into account, the agreement between experiment and theory can be potentially improved. However, previous theoretical results corresponding to 1/9 ML or 1/4 ML should not be directly comparable to the experimentally derived S0. The requirements of a larger supercell to fulfill the quasi-zero-coverage condition and a higher level of description of adiabatic and nonadiabatic molecule-surface interactions will motivate future theoretical studies.
Supplementary materials: Temperature programmed desorption measurement of HCl on Au(111), measurement of nozzle temperature, and measurement of the hydrodynamic enrichment factor are shown.
Coverage Dependent Dissociative Adsorption of HCl on Au(111)
- Received Date: 31/12/2023
- Available Online: 27/08/2024
-
Key words:
- Dissociative adsorption /
- Reaction probability /
- Molecular beam /
- Density functional theory
Abstract: Dissociative adsorption of HCl on Au(111) has become one of unsolved puzzles in surface chemistry. Despite tremendous efforts in the past years, various theoretical models still greatly overestimate the zero-coverage initial sticking probabilities (S0). To find the origin of the large experiment-theory discrepancy, we have revisited the dissociative adsorption of HCl on Au(111) with a newly designed molecular beam-surface apparatus. The zero-coverage S0 derived from Cl-coverage measurements with varying HCl doses agree well with previous ones. However, we notice a sharp change of the coverage/dose slope with the HCl dosage at the low coverage regime, which may result in some uncertainties to the fitted S0 value. This seems consistent with a coverage-dependence of the dissociation barrier predicted by density functional theory at low Cl-coverages. Our results reveal the potential inconsistency of utilizing simulations with finite coverage to compare against experimental data with zero coverage in this system, and provide guidance for improving both experiment and theory in this regard.