The electrochemical energy-substance conversion technology such as fuel cells and electrolysers for generating hydrogen from water, organic molecules from CO2, ammonia from N2 and so on, is of great potential in solving the energy crisis and mitigating the environmental problems. However, the advancement and large-scale commercialization of these technologies are still too slow. The lack of high-performance electrocatalysts remains one of the most prominent challenges for these technologies. Developing electrocatalysts with high intrinsic activity for such electrochemical energy conversion systems, is one of the central tasks for the electrochemical community in the past decades. Model studies in classical three-electrode systems are efficient ways to scrutinize the reaction behavior of the electrocatalysts and for optimize electrolyte compositions, which have been widely exploited [1-4]. Rich instructive information, such as the intrinsic kinetics of electrocatalytic reactions, the activity trends of electrocatalysts with various element compositions or morphologies, as well as the comparison of activity trends upon change of electrolyte conditions such as solution pH, solution compositions and so on, have been provided [5-7]. The knowledge gained has greatly helped to establish the principles of electrocatalysis, rationally design electrocatalysts with improved activity, or optimize reaction conditions for the electrochemical devices.
Despite of the achievements mentioned above, some problems still exist. Many good electrocatalysts reported to have good catalytic activities cannot be proven in real devices, various reasons may lead to such a situation [2, 8-10]. One fact we commonly face is that the experimental data reported from different groups or even from the same group are not well reproducible at all. For example, platinum (Pt) is identified to be the most active catalyst for hydrogen evolution reaction (HER). The exchange current (density),
$ {i}_{0} $ , has been widely used as a parameter to evaluate the activity of relevant electrocatalysts for HER [11, 12]. However, even on the well-defined Pt(111) as a model catalyst, the values of$ {i}_{0} $ for HER or$ i $ measured at certain overpotential previously reported can vary from several times up to more than two orders [11]. In addition to the possible difference in the structure and composition of the electrocatalysts [3, 13, 14], several other origins may also lead to such deviation, such as the insufficient Ohmic compensation of the solution resistance [15, 16], the change of solution pH and the concentration of H+ and H2 in the solution [11, 17], and deviation of reaction temperatures [13, 18, 19]. Besides, dissolution of Pt from counter electrode and its redeposition onto the working electrode has been more and more widely recognized [20, 21].There are other factors that can also greatly impact the evaluation of the intrinsic electrocatalytic activity, however, they have been frequently overlooked. One problem is the involvement of small amounts of defects which are far more active than other sites of the electrocatalysts under investigation. Another frequently encountered interference is from trace impurities of the reagent used for preparation of the supporting electrolyte, especially those containing components which has much higher electrocatalytic activities than those of the electrocatalysts under investigation [22]. In this work, we demonstrate such interferences by taking Au(111) as the model electrocatalysts, and HER in 0.1 mol/L NaOH solution under a hanging meniscus rotation electrode (HMRDE) configuration as the model reaction. We choose Au(111) as the model electrocatalysts since it has poor electrocatalysts for HER, with its first charge transfer step, i.e., as the rate-determining step. Furthermore, the mechanism for HER at Au(111) does not change over a broad pH regime from 0 to 16. Hence, it is an ideal model system to study the kinetics of elementary proton coupled electron transfer, to investigate the impact of pH [5, 6, 23, 24] and cation effects [25-29].
This paper is organized as follows: we first analyze the scattering of the HER activity data on Au(111). Then we discuss how the meniscus height, the possible involvement of highly active edge sites, and the possible deposition of highly active elements can interfere with the evaluation of the intrinsic HER kinetics. Finally we briefly discuss the implication of present findings for the kinetic analysis of other electrocatalytic reactions.
-
All the electrolyte solutions were prepared using Millipore water (18.2 MΩ·cm). 0.05 mol/L H2SO4 or x mol/L NaOH solutions were used as supporting electrolyte, which was prepared using H2SO4 (70%–72%, Aladdin) or NaOH (99.99%, Merck, 32% solution). NaOH was used without or with further purification by electrolysis. The purification of NaOH was performed as follows: 500 mL 32% solution of NaOH electrolyte was prepared. Two pieces of Au foil (puratronic 99.999%, 0.25 mm; TANAKA Precious Metals) were used as working and counter electrodes. The surface area of the working electrode was 2 cm2. The electrolysis was carried out in a polypropene bottle under stirring of the electrolyte at 500 r/min and under purging of the electrolyte with Ar (5 N) at 10 sccm. The applied potential was −2 V vs. the Au foil. The electrodes were removed from the electrolyte under applied bias after ~30 h at the current of 420 mA.
A conventional three-electrode cell was used for the electrochemical measurements. Electrolyte solution was de-aerated with purified Ar gas (5 N) for 20 min before each experiment. During the measurements, the electrolyte was constantly purged with Ar. The Au(111) was prepared according to Clavlier’s method [30] and used as the working electrode (WE), a saturated calomel electrode (SCE), connected to the cell through a long Luggin capillary was used as the reference electrode (RE), an Au wire was used as the counter electrode (CE). Before each experiment, the Au(111) electrode was flame-annealed followed by quenching in ultrapure water. During the transfer of the WE, the electrode surface was protected with ultrapure water to prevent contamination by airborne impurities. The electrode surface was covered with deoxygenated water droplets during the transfer to the electrochemical cell to avoid contact with impurities. The measurements of the
$j\text{-}E$ curves were carried out under HMRDE configuration with a rotation speed of 2500 r/min with an Ohmic compensation of 95% [15]. Unless specifically mentioned, the meniscus height was carefully adjusted to make sure that only the sites from the (111) plane (no edge sites from the sphere) were involved in the reaction (FIG. 1(c)). The currents were normalized to the geometric surface areas of the WE to obtain the current density. All measurements were done at room temperature, and all the potentials quoted in this study are against RHE. -
Prior to presenting our experimental findings, we first make a comparison of experimental results for HER at Au(111) in acidic and alkaline solutions reported in previous studies (FIG. 2) [5, 23, 29, 31-36]. The data compilation in FIG. 2 (a) and (b) reveals significant discrepancies in the measured
$j\text{-}E$ characteristics from different research groups [29, 31-36]. Detailed experimental conditions and some literature not included in FIG. 2 are shown in Table I.For the case with HER at Au(111) in 0.1 mol/L HClO4 (FIG. 2(a)) [31-34], the observed onset potential for HER can vary from ca. −0.05 V to −0.2 V. At −0.25 V, the highest-performing HER activity (curve 4) exhibits about 75-fold greater current density compared to the poorest-performing activity (curve 2) . Ultrapure HClO4 is used in these studies, with chloride contaminants remaining at trace levels. These minimal Cl− concentrations are unlikely to significantly influence HER activity because the Au(111) surface maintains a negative charge under HER conditions, effectively repelling anion adsorption. The observed discrepancies in HER activity among different research groups are more likely due to the variations of the quality of the Au(111) electrodes [3]. Specifically, Au(111) electrodes displaying elevated onset potentials likely contain structural imperfections, such as surface defects or edge atoms from bead-type crystal surfaces which may be introduced due to the cycling potentials to above 1.3 V [34, 39] or due to surface reconstruction under HER potentials [3]. This is supported by the differences in the two representative sets of base CVs shown in FIG. 3. The Au(111) with the best quality (with sharp spikes at ca. 1.1 V in CVs) which has also been well characterized by electrochemical in-situ scanning tunneling microscopy has smaller HER current densities (FIG. 2(a)) [32].
For HER at Au(111) in 0.1 mol/L NaOH (FIG. 2(b)) [25, 29, 35, 36], the onset potential varies significantly, ranging from approximately −0.2 V to −0.5 V. Current densities at −0.6 V also show substantial deviations, with curve 7 exhibiting over three times higher activity compared to curve 6. Multiple factors contribute to these variations in HER kinetics. Different research groups often employ slightly different experimental conditions. Additionally, except our own work [23], most previously published papers have not provided basic cyclic voltammograms (CVs) to verify Au(111) electrode quality. These limitations make it challenging to determine the exact origins of the observed deviations based solely on the data shown in FIG. 2. On the other hand, reported pH and cation effects on HER kinetics are relatively modest [25, 26], in particular, increasing pH by one unit within the range of 10 to 13 (FIG. 2(c)) or switching from LiOH to CsOH (FIG. 2(d)) results in activity variations below three times. To accurately resolve pH and cation effects on HER at Au(111) in alkaline media, it is essential to minimize other factors which may also lead to a change of HER activity of similar extent. Frequency check of the quality of Au(111) surface as well as cleanness of the cell system is highly recommended in order to make sure that under identical experimental conditions the experimental errors should ideally be kept below 20%.
-
Alkaline solutions are known to have high viscosity, and the liquid can climb up to the edge of the electrode easily. To make sure that the impact caused by this phenomenon is negligibly, in the experiments, we have always carefully adjusted the meniscus height. Here, we first demonstrate how the variation of the meniscus height alters HER current at Au(111)/NaOH interface. Three representative
$j\text{-}E$ curves for HER recorded at three different meniscus heights (8 mm, 10 mm, 12 mm) have been displayed in FIG. 4(a) and the corresponding basic CVs are shown in FIG. 4(b). FIG. 4(a) clearly shows that HER current increases significantly with decreasing the meniscus height. However, from FIG. 4(b) we see that there are almost no differences for the basic CVs of Au(111)/NaOH interface with different meniscus heights in the range of 8 mm to 12 mm. The latter indicates that even though the meniscus height is as small as 8 mm, the part of the bead electrode still barely contacts with the liquid. The significant enhancement of HER current is probably because most sites are steps, kinks, or defects at the edge of sphere close to the base (111) plane. Each has significantly higher intrinsic HER activity, although the overall numbers of such sites are rather small similar to those found for the case in acid (FIG. 2(a) and FIG. 3). The latter has been well confirmed by combined EC and scan tunneling microscopy(STM) previously [3]. Compared to the amount of atomic sites at the (111) plane, such active sites are minor, hence their capacitive contribution to the basic CVs is negligible. Comparing the$j\text{-}E$ curves in FIG. 4(a) with those displayed in FIG. 2 (c) and (d), we find their variations in the same range, hence one should be very careful to ensure that the meniscus heights are kept in the same range when studying the pH and cations effect on HER. -
As a research group have more than 15 years of experience in experiments with single-crystal electrodes, we are well aware of the purity issues of the glass cell, purging gas, water, and the reagent used for preparing the solutions. We always try our best to avoid any contaminants on the electrochemical behavior under investigation. For studying the HER behavior at Au(111), we also tried to use the reagent with the highest purity commercially available (e.g., NaOH, 99.99%; Merck, 32% solution). However, strange phenomena are frequently observed, and typical experimental data are displayed in FIG. 5. With continuous potential scanning into HER potential region, we found that HER activity increases continuously with the potential cycles (FIG. 5(a)). We tried to check the quality of Au(111) in 0.05 mol/L H2SO4 using CV, the basic CVs recorded before and after HER are shown in FIG. 5(b). The CVs recorded after HER was done as follows: the electrode is pulled out from the cell with 0.1 mol/L NaOH, it was washed with large amount of water with high purity (Milli-Q). There are almost no differences between the CVs recorded before and after taking the
$j\text{-}E$ curves for HER, leading us to conclude that Au(111) surface structure and composition did not change during HER. However, this cannot explain why HER current increases with continuous potential cycles. So, we have also carried out chronoamperometry with two typical current transients for HER on Au(111)/0.1 mol/L NaOH interface at −0.4 V and −0.5 V, as shown in FIG. 5(c). Significant increase in HER current with reaction times has also been observed. The basic CVs in 0.05 mol/L H2SO4 recorded before and after recording the current transient for HER are also shown in FIG. 5(d). Again, almost no differences between the CVs before and after recording the current transients for HER can be discerned.When checking the datasheet of 32% NaOH, we found that it may contain Al, Fe, and Ni at a concentration of ca. ≤10, 4, and 2 mg/L, respectively. We speculate such metals also exist in our reagent with 32% NaOH. Hence, we tried to purify the as-received NaOH solution by electrolysis. After continuous electrolysis at 420 mA for approximately 30 h, inductively coupled plasma mass spectrometry (ICP-MS) was employed to characterize the Fe and Ni contents in 0.01 mol/L NaOH before and after purification to evaluate the purification efficacy. The results showed that the pre-purification concentrations of Fe and Ni were 6.848 ppb and 0.414 ppb, respectively, while post-purification values decreased to 2.759 ppb and 0.158 ppb (FIG. S1 in SM). The purification process effectively reduces impurities to levels negligible for the target electrocatalytic reaction. This indicates that during the electrolysis process,
$ {\mathrm{F}\mathrm{e}}^{2+} $ and$ {\mathrm{N}\mathrm{i}}^{2+} $ ions were reduced to their elemental forms ($ {\mathrm{F}\mathrm{e}}^{2+}+2{\mathrm{e}}^{-}\to \mathrm{F}\mathrm{e} $ ,${\mathrm{N}\mathrm{i}}^{2+}+2{\mathrm{e}}^{-}\to \mathrm{N}\mathrm{i}$ )), confirming that the purification technique used in the experiment effectively removed Fe and Ni from the solution.However, the effectiveness of this purification must be validated through comparative electrochemical characterization with the unpurified solution. To this end, NaOH solutions with concentrations of
$ x $ mol/L (with$ x $ from 0.1 to 5) were prepared using the purified NaOH, and some representative data recorded in NaOH solutions with and without purification by electrolysis are given in FIG. 6. After purification, the HER current does not increase with continuous potential cycling in 0.1 mol/L NaOH in the potential regime from 0.1 V to −0.65 V (FIG. 6(a)); and it does not change with elongated reaction time when recording the current transients at −0.5 V (FIG. 6(c)). In purified 0.1 mol/L to 5 mol/L NaOH, the HER current at Au(111) is ca. 2 times smaller compared to that of the same concentration but without purification (FIG. 6(b)). Furthermore, the higher the NaOH concentration is, the larger the deviation between HER current with and without purification is observed. All these imply that Fe, Ni or Al has probably deposited on Au(111) under HER conditions [40], which leads to the enhancement of the HER current measured. Similar enhancement of HER activity at pc-Au through polishing using Al2O3 as the polishing power has been reported previously [41].In order to verify whether there are some changes of catalysts surface structure or compositions, the most convenient way is using cyclic voltammetry. However, such a method sometimes is cheating, the CVs are comparable with or without purification as seen from typical examples displayed in FIG. 5(b, d) and FIG. 6(d). Why does the deposited Fe on Au(111) not distort the basic CVs of Au(111) recorded in 0.05 mol/L H2SO4 or in 0.1 mol/L NaOH (blue line in FIG. 6(d))? We think it is probable that the Fe dissolved when Fe deposited Au(111) was left at open circuit potential (OCP) right after recording the
$j\text{-}E$ curves or$j\text{-}t$ curves for HER, since the standard redox potential for Fe2+/Fe, Ni2+/Ni, etc. are far below the OCP for Au(111)/0.1 mol/L NaOH interface (ca. 0.2 V).Hence, we tried to record the basic CVs from −0.5 V to 1.25 V (only the data in the range of 0.2 V to 1.2 V are shown for comparison), right after HER, without leaving the WE out of potential control (red line in FIG. 6(d)). The significant broadening of the double-layer charging region for the CV curves, compared to those recorded in purified NaOH solutions further supports that most probably Ni, Fe, etc. contaminants deposited on Au(111) during HER are probably further oxidized to NiOOH, Fe2O3, etc.
To ensure accuracy, immediately after the HER in all solutions, we recorded the basic CV without leaving the WE out of potential control (FIG. 7(a)). It can be observed that even when maintaining potential control, the CV curves of all solutions show almost no changes before and after HER. FIG. 7(b) also presents the basic CV of the Au(111) electrode in 0.05 mol/L H2SO4 solution after HER, which is nearly identical to that before the reaction. This further demonstrates the effectiveness of the purification and confirms that the quality of the electrode surface remains unaltered. Present results indicate that careful characterization of the structure and composition of the electrocatalysts right before and after investigating the reaction kinetics is necessary, if on-line examination is not convenient. For those contaminants which are easily oxidized at low potentials, cyclic voltammetry for such characterization, should maintain potential control right after measuring the reaction activity in order to detect the redox behavior of such contaminants.
-
The results gained in this work remind us that in order to get the intrinsic activity of a single-crystalline model electrode (M(hkl)), one should be very careful to make sure the quality of M(hkl) plane. Furthermore, contributions from edge sites near the (hkl) base plane must be minimized through precise control of the meniscus height. For this purpose, one should carefully adjust the meniscus height. On one hand, it should be as high as possible to avoid the involvement of metal atoms on the edge of the half-sphere into HER (FIG. 1); on the other hand, it should not be so high that one may lose the meniscus contact between M(hkl) and the electrolyte solution even during the measurement under high rotation speed. Especially in the studies of the pH effects or cation effects which are rather mild (less than 4 times with change or one pH unit or with changing M+ with increase of just one electronic shell, FIG. 2 (c) and (d)), one has to frequently immerse the electrode into different solutions. Keeping the appropriate meniscus height and frequently checking the quality of the M(hkl) model electrode surfaces are the prerequisites to get reliable the structure-activity relationship or activity trends in such studies.
Our results further remind us that when studying electrocatalytic behavior of catalysts with weak catalytic activity, great care should be paid when there are possible interferences from the deposition of trace amount elements with much higher catalytic activity. Such contaminants may come from the reagents used for preparing the solutions (even with the highest grade commercially available, sometimes the claimed purity scale is not actually reached at all), or may be dissolved from the glass cell used in the investigation or from other metallic parts of the cell (such as counter electrodes) which may contact the electrolyte [42]. Such an interference can be huge, which may greatly hamper the accurate identification of activity trends for the pH and cation effects, since the contaminants involved in different solutions increase with the amount of NaOH used for preparing the solution. Deposition of trace metals (Cu, Zn, Pb, and Fe) from electrolyte salts on the Pt surface during the HER was also reported previously, which has been confirmed to be the main origin for deactivating Pt toward HER [43].
Furthermore, when trying to verify whether there is deposition of such elements with high activity using the CV, one should be very careful that the deposited elements may dissolve at the OCV before the CVs are taken. Furthermore, it is well known that alkaline solution has strong capability to corrode the glass cell. One may try to use cells made of PEEK or PTFEs etc. to avoid the leakage of possible contaminants from the glass with Fe2+ or other metal ions. Since our measurements need to adjust the meniscus height, transparent glass cells are preferred. Under such circumstance, one should be very careful to choose the right glass with less dissolvable cations which can be deposited to the WE and interfere the catalytic activity.
Moreover, our findings also emphasize that basic CV measurements alone are not sensitive enough to determine whether edge sites participate in reactions, since the amount of such sites is rather small. For such scenarios, deep-thought experiments or measurements with other experimental techniques are highly recommended [22]. Additionally, for electrocatalysis studies in alkaline media, the use of a Hg|HgO reference electrode is advisable. Our experiments confirm that employing Ag|AgCl (saturated KCl) or a saturated calomel electrode (SCE), even when placed outside the cell and connected via a long Luggin capillary, often results in continuous potential drift [44]. This phenomenon can significantly compromise the precise control of applied potential and thermodynamic driving force, thereby hindering the accurate derivation of intrinsic reaction kinetics.
We propose a straightforward and accessible method to assess the impact of trace impurities in solution on electrocatalytic reactions. This approach involves conducting consecutive linear sweep voltammetry scans. If the polarization curves exhibit changes with increasing scan cycles (FIG. 5(a)), it suggests the potential presence of trace impurities or restructuring of M(hkl) in the electrolyte. Conversely, stable polarization curves across multiple cycles (FIG. 6(a)) confirm the effective removal of impurities and well control of the M(hkl) structure, regardless of the purification methods used. This method is broadly applicable to other electrocatalytic reactions, such as electrochemical CO2 reduction [45].
Finally, it should be mentioned that HER activity on Au(111) increases with the increase of NaOH concentrations from 1 mol/L to 5 mol/L (FIG. 6(b), up to 9 mol/L, not included). In contrast, Koper et al. recently reported that in solutions with low pH (pH≈10 and 11), HER current increases with cations concentration, while in solutions with pH=13, HER activity decreases with cations concentration above 0.1 mol/L or with increased electrode rotation speed [25, 46]. Such a trend differs significantly from what is observed by us with purified NaOH, and the origins for the increase of HER activity at Au(111) with NaOH concentration, as well as possible origins for discrepancies between results from our group to Koper’s group, will be discussed in detail elsewhere.
-
The impact of the single-crystalline electrode surface quality, possible involvement of more active edge sites, possible deposition of contaminants onto the electrode surfaces on unveiling the intrinsic electrocatalytic activity and structure-activity relationship has been addressed using HER at Au(111) electrode in NaOH electrolyte as a model system. Our results demonstrate that the involvement of defects and deposited elements with higher activity than terrace sites can lead to enhancement of HER current by 1–2 orders of magnitude, which can be significantly larger than from the change of solution pH or the nature of cations. To unravel the intrinsic electrocatalytic activity and derive the structure-activity relationship, it is crucial to use high-purity electrolytes and meticulously control the quality to minimize the influence of impurities. Purification of the electrolyte such as pre-electrolysis can greatly help minimize the impact of metal cation impurities on the HER performance. To unveil the pH effect and cation effect on electrocatalytic processes, one should frequently characterize the quality of M(hkl) surfaces to make sure the impact of electrocatalytic activity from the change of the structure of compositions to be negligible compared with that of variation in solution pH or cations identity. We hope this work will be of great help for derivating structure-activity relationship, investigating the pH effect and cation effect on electrocatalytic processes, and quantifying the intrinsic kinetic parameters for electrocatalytic processes.
Frequently Encountered Factors Which Obstruct Evaluation of Intrinsic Kinetics of Electrocatalytic Reactions
- Received Date: 19/03/2025
- Available Online: 27/10/2026
-
Key words:
- Hydrogen evolution reaction /
- Au(111) /
- Alkaline solution /
- Trace impurities /
- Edge effect
Abstract: Obtaining reproducible experimental data free from artifacts is of paramount importance in evaluating the intrinsic kinetics of electrocatalytic reactions, discovering the activity trends, and unveiling the intrinsic effects from the electrolyte such as solution pH and composition ions. In this work, we will take hydrogen evolution reaction (HER) at Au(111) electrode under hanging meniscus rotating disk electrode (HMRDE) configuration as a model reaction. The impacts of the quality of single crystal electrode (the height of hanging meniscus of the HMRDE), possible participation of edge sites between the sphere and (111) plane, and the purity of the reagents used for preparing the supporting electrolyte on the