Great efforts are being made to develop time-resolved electron-based imaging techniques, driven by their promising applications in real-space microscopy [1] and diffraction [2]. On the other hand, the spatial resolution of electron microscopy is primarily determined by the spatial coherence [3]. To date, the combination of time-resolved capabilities with highly coherent electron emission remains unrealized, presenting both opportunities and challenges [4]. Nonetheless, solid steps at each side are also full of meaning. Since scattering cross sections increase substantially as electron energy decreases to hundreds or tens of electron volts, low-energy electron diffraction (LEED) has been a widely used tool for surface structure determination. Thus, time-resolved LEED benefits from a pulsed electron beam with a short time width [5]. Furthermore, reduced tip dimension is essential for enhancing the spatial coherence of emitted electrons [6]. In this Letter, we report our recent progress in simultaneously advancing both aspects and discuss the potential applications of our approach.
Our electron diffractometer is designed as a point-projection microscope [7], primarily consisting of a femtosecond laser system, a sample positioning system, a tungsten needle, a microchannel plate (MCP)−phosphor screen detector assembly, and a charge-coupled device (CCD) camera. FIG. 1 shows the experimental setup. In FIG. 1(a), the part within the black broken-line frame represents a vacuum chamber. An enlarged scheme in FIG. 1(b) comprises the focused laser beam, the nanotip, and the sample holder (as schemed in FIG. 1(c)). Scanning electron micrographs (SEM) of our homemade electrochemically etched tungsten needle are shown in FIG. 1(d). It is noted that the laser system in FIG. 1(a) is arranged for a pump (femtosecond laser)−probe (LEED) experiment, while we employ this arrangement specially for the identification of the pulse width of laser-triggered electron emission in this work. Briefly, 35 fs optical pulses centered at 800 nm from an amplified Ti:sapphire laser system are used to initiate photoexcitation of a copper grid, and the pump-induced structural changes of the grid are measured by taking snapshot images of the photoelectron patterns at different delay times (Δt).
A dense electron cloud is produced upon excitation of a single copper grid bar, which leads to spatial deflection of the passing electron pulse [5]. Shadow images of the grid (Z1=1.8 mm and Z2=84 mm, with the needle voltage of about −340 V) are recorded at various Δt values with the pump laser activated, as shown in FIG. 2(a). Each image corresponds to an integration time of 20 s, comprising 200 k pulses at a laser power of 24.5 mW. Correspondingly, the integrated shadow image intensity (inside the circle denoted in FIG. 2(a)) as a function of pump−probe Δt is plotted in FIG. 2(b). The rising time of the curve reflects the dynamics of the electric field buildup and its interaction with the electron beam, and its deviation (broken curve in FIG. 2(b)) shows a full-width at half-maximum (FWHM) of 7.6 ± 0.3 ps, namely, a typical temporal width of the electron pulses. As shown in FIG. 2(c), the FWHM value decreases with increasing electron energy and is expected to be further reduced if the electron energy is enhanced, for example, about 1.95 ps at 450 eV [5]. However, the observed dependence of FWHM on the laser power seems counterintuitive: the larger electron clouds on the grid produced by stronger laser pulse could result in more time-consuming deflection of the passing electrons. In fact, the electron clouds produced by the stronger laser pulse quickly dissipate due to the higher translational energies of these electrons [8].
In principle, the measured FWHM (τ) comprises the following contributions,
where τpump is the pulse width of the pump laser, τprobe is the pulse width of the electron upon arrival at the sample, τE is the time for electron cloud formation on the grid [9], and τmismatch is the mismatch time between the laser-pump and electron-probe pulses [10]. In the present case, τpump=35 fs, τE is 1−2 ps [9]. Since τmismatch is primarily determined by the spatial mismatch size between the laser-pump and electron-probe beams at the grid, given by
where
$ \omega $ is the electron-probe beam size,$ \theta $ is the crossing angle between the laser-pump and electron-probe beams, and c is the light speed. Considering the parameters ω (70 μm) and θ (75°) values of the present arrangement (FIG. 1(a)), we have τmismatch=0.22 ps. The τprobe value is further estimated as 7.3 ps according to the measured τ=7.6 ps in FIG. 2(b). Therefore, a shorter τprobe can be obtained for a stronger laser-pump pulse, also with a proper geometrical arrangement of the laser-pump and electron-probe beams.The point-projection microscope arrangement is also used for the production of coherent electron beam, by modifying the following items: as shown in FIG. 3(a), a DC-field emission mode is used and the needle is much closer to the sample (Z1=5–75 μm); a commercial needle with a much sharper tip (ALES TECH. Inc.), as depictured in FIG. 3(b), is used; a silicon nitride grid covered with a gold film (10 nm in thickness) and with uniformly distributed holes (2.8 μm in diameter) is used as the sample carrier (the left picture of FIG. 3(c)), the silver nanolines (60 nm in diameter) are put on the grid (the middle and right pictures of FIG. 3(c)).
As shown in FIG. 3(c), the electron emission is quickly enhanced when the needle tip is closer to the sample on the grid, thus we have to reduce the voltage on the needle to prevent tip damage. When the tip is about 2.1 μm from the sample and the needle voltage is −120 V, a clear electron diffraction picture is recorded and shown as the inset of FIG. 4. The fringes observed in this picture are primarily due to the Huygens–Fresnel interference between diffracted and non-diffracted electron waves [11]. Along the short solid line, the pixel intensities within the region between the two broken purple lines are summarized and then plotted as the curve in FIG. 4. The distinct diffraction fringes are shown as the intensity fluctuations from 0 to 70 nm, indicating a transverse coherence length of 70 nm at the sample. Correspondingly, the full width ξ⊥ of coherent illumination region at the detector screen is 2.8 mm. The above values are commonly quantified by means of the effective source radius reff of the needle tip [4]. In this work, the tip’s apex radius is 5 nm (FIG. 3(b)), thus reff is expected to be smaller than this size. According to the van Cittert–Zernicke theorem for an incoherent emitter with a Gaussian intensity profile [12],
where λ is the electron de Broglie wavelength. In the present case, λ is 0.11 nm, thus reff is estimated to be 1 nm. The transverse coherence length could be larger with a smaller reff value, which demands more precise fabrication techniques. The DC current of the coherent electrons is about several nano-amperes, which is estimated with the Fowler-Nordheim formula of the field emission [13, 14].
At last, we give a perspective about the potential developments and address the challenges in combining the above two techniques. The pulse width of electron bunches could be of femtoseconds, but the electron energy is usually about million eV [15] and the electron bunches need to be reshaped [16]. Atomic-level sharp needle could be produced [17], which would substantially enhance the transverse coherence length of the electrons. However, it is difficult to produce such coherent photoelectrons by focusing a laser on an extremely small region of the sharp needle tip. Meanwhile, ultra-sharp tips are fragile and easily damaged by laser pulses. More advanced techniques are still in demand for the development of an ultrafast-coherent electron source.
Pulsed and Coherent Electron Emission from Tungsten Nanotips
- Received Date: 09/02/2026
- Available Online: 27/06/2026
-
Key words:
- Electron source /
- Coherence length /
- Time-resolved technique /
- Femtosecond pulse /
- Nanotip
Abstract: Pulsed coherent electron sources are highly demanded for the development of time-resolved electron diffraction and imaging techniques. Here, we report quantitative measurements of the pulse width and spatial coherence for electrons emitted from tungsten nanotips. The pulse width of 340 eV electrons from a homemade needle is determined to be about 7.3 ps using a pump (femtosecond optical pulse)−probe (electron pulse) method. DC-field emission from a commercial sharp tungsten needle tip achieves a transverse coherence length of about 70 nm. These results highlight the potential of tip-based electron sources for ultrafast electron diffraction and imaging applications.