2024 Volume 33 Issue 8
Article Contents

Hong Chang, Xin Yang, Yan Ma, Xinqi Yang, Mingtao Cao, Xiaofei Zhang, Ruifang Dong, Shougang Zhang. Optical storage of circular airy beam in atomic vapor[J]. Chinese Physics B, 2024, 33(8): 084202. doi: 10.1088/1674-1056/ad4bbf
Citation: Hong Chang, Xin Yang, Yan Ma, Xinqi Yang, Mingtao Cao, Xiaofei Zhang, Ruifang Dong, Shougang Zhang. Optical storage of circular airy beam in atomic vapor[J]. Chinese Physics B, 2024, 33(8): 084202. doi: 10.1088/1674-1056/ad4bbf

Optical storage of circular airy beam in atomic vapor

  • Received Date: 19/02/2024
    Accepted Date: 27/04/2024
    Available Online: 01/07/2024
通讯作者: 陈斌, bchen63@163.com
  • 1. 

    沈阳化工大学材料科学与工程学院 沈阳 110142

  1. 本站搜索
  2. 百度学术搜索
  3. 万方数据库搜索
  4. CNKI搜索

Figures(5)  /  Tables(2)

Article Metrics

Article views(559) PDF downloads(2) Cited by(0)

Access History

Optical storage of circular airy beam in atomic vapor

Abstract: The realization of quantum storage of spatial light field is of great significance to the construction of high-dimensional quantum repeater. In this paper, we experimentally realize the storage and retrieval of circular Airy beams (CABs) by using the Λ-type three-level energy system based on the electromagnetically induced transparency in a hot rubidium atomic vapor cell. The weak probe beam field is modulated with phase distribution of CABs by a spatial light modulator. We store the probe circular Airy beam (CAB) into the rubidium atomic vapor cell and retrieve it after the demanded delay. We quantitatively analyze the storage results and give corresponding theoretical explanations. Moreover, we investigate the autofocusing and self-healing effect of the retrieved CAB, which indicates that the properties and beam shape of CAB maintain well after storage. Our work will have potential applications in the storage of high-dimensional quantum information, and is also useful for improving the channel capacities of quantum internet.

1.   Introduction
  • Circular Airy beams (CABs) have attained much attention because of their abruptly autofocusing property,[1–3] which were first proposed in 2010[1] and investigated by experiment in 2011.[2,3] Due to the self-bending property of Airy beam,[4,5] the circular Airy beam (CAB) will suddenly autofocus in the focal region. The energy flows from the main ring to the center of CAB. Therefore, the autofocusing property of CAB has been widely used in optical tweezers,[6–9] light bullet,[10–12] atom manipulation[13,14] and quantum information.[15–17]

    Studies on the self-bending behavior of the Airy beam show that its parabolic trajectory is controllable[18–20] by changing the initial incidence angle of Airy beams[18] or the refractive index gradient of the medium.[20] Moreover, the manipulation of the Airy beams’ deflection position by changing the Rabi frequencies of the control beam in the atomic vapor with the electromagnetically induced transparency (EIT) scheme has been theoretically proposed by Zhuang et al.[21] Later, manipulating the Airy beams between atom–light interface has attracted much attention.[21–26] In the atomic system, the manipulation of the self-accelerating beams’ propagation properties can be realized in the EIT scheme,[21–23] which can be extended to two-dimensional[23,25] and three-dimensional[26] self-accelerating beams. The EIT protocol also presents the possibility to store the Airy beam to the atomic medium, which has potential applications in the storage of high-dimensional quantum information.

    Principally, the storage of CAB can be realized by different quantum memory protocols, such as, the Duan–Lukin–Cirac–Zoller protocol,[27] EIT protocol,[28–31] photo-echo protocol,[32,33] and Raman protocol.[34,35] Among these protocols, EIT has been selected as the most popular candidate to store spatial mode information.[22,36–38] The storage of Airy wave packets has been theoretically investigated in the EIT-driven atomic gas by Hang et al.[22,36] Then, the storage of 2D Airy wave packet experimentally demonstrated in a doped solid EIT-driven by Wang et al.[37] and in atomic vapor by Wang et al.[38] However, the storage of CAB has not yet been investigated experimentally, which is essentially important because of the abruptly autofocusing property in atomic medium that could be employed to present the waveguided multiplexed quantum memory.

    In this paper, we experimentally investigate the storage of CAB in a hot atomic vapor with EIT scheme. The experimental results show that the autofocusing and self-healing effect of the retrieved CAB can be well preserved. Our results will be useful for high-dimensional spatial multi-modes storage and high-dimensional quantum information communication.[15,16,39–44]

2.   Theoretical analysis
  • The electric field of CAB at the initial plane is expressed as[1,44,45]

    where (x, y) is the Cartesian coordinate system, Ai is the Airy function, and its expression is

    The t means the variable of integration.[46]r0, ω and b are respectively the radius of the main ring, the radial width, and the distribution factor of CAB in the initial plane. a is a decay factor.

    As shown in Fig. 2, the CAB consists of several rings at the initial image plane. The CAB possesses abruptly autofocusing property because of the characteristics of the Airy function. The radius of the main ring of CAB also follows a parabolic trajectory before reaching its focus.[2,18] The focal position zf is defined as[47]

    where λ is the wavelength, which is 795 nm in this paper. Herein, the light power is 630 μW, the other parameters are r0 = 0.5 mm, a = 0.1, b = 0.022, ω = 2 mm. Then we can calculate this CAB will autofocus at zf = 695 mm.

3.   Experimental configuration
  • The schematic experimental setup is depicted in Fig. 1. In Fig. 1(a), the two laser beams respectively from the laser 1 (EFL-SSHG-795-DFB) and laser 2 (EFL-SSHG-795-FECL) are defined as the probe and control beams. After the two beams of the laser 1 and laser 2 pass through the single-mode fiber to improve the spatial mode, they are frequency shifted by the acousto-optic modulator (AOM), as shown in Fig. 1(c). It is well known that Airy wave packets can be generated via the Fourier transformation of a Gaussian beam modulated with a cubic phase.[48] Thus, Airy beam becomes a CAB in polar coordinates. In our experiments, a spatial light modulator (SLM, HDSLM80R Plus) is utilized to generate a CAB, which is defined as the probe beam with a power of 630 μW and a diameter of 2 mm. A beam splitter (BS) is used to separate the probe beam into two beams, and one of them is defined as the reference beam. Meanwhile, a telescope consisting of f3 and f4 is used to expand the control beam size and the achieved high-quality Gaussian beam is about 4 mm in diameter. A 70 mm long 85Rb atomic gas cell is placed in a three-layer μ-metal magnetic shield and is set to 55 °C with a temperature controller. Finally, the probe and control beams are injected into the hot rubidium cell in the same direction.

    The energy level structure is as shown in Fig. 1(d). The 795 nm probe laser is frequency-locked to the 85Rb D1 line with the crossover transition 52S1/2, F = 2 → 52 P1/2, F′ = 2, 3, which is depicted as the co(2,3) in Fig. 1(d). The control laser is phase-locked to the probe laser and is resonant with the crossover transition 52S1/2, F = 3 → 52P1/2, F′ = 2, 3. The experimental parameters of the two beams can be controlled independently. These two beams form a typical Λ-type EIT system to perform the experiment.

    In the experiment, the beams from laser 1 and laser 2 pass through the double-pass AOM, and then the frequencies of both probe and control beams are shifted by 180.8 MHz. Thus, the probe and control beams are resonant with the 52S1/2, F = 2 → 52 P1/2, F′ = 3 transition and the 52S1/2, F = 3 → 52 P1/2, F′ = 3 transition, respectively. The probe beam with the horizontally polarized is imaged to the center of the cell by a 4f system with f7 and f8, as depicted in Fig. 1(c). A circular aperture is positioned at the focal plane of the 4f system to act as a filter, selecting the zero-order diffracted spot of CAB appearing in the Fourier plane. After the SLM, the reflected beam passes through the Fourier transform lens f8 to observe the CAB profile at the focal point of the f8. The reference beam is directly coupled on the photodiode detector (PD, Thorlabs PDA8A2). The size of vertically polarized control beam, with a power of 60 mW, completely covers the probe CAB. And it propagates collinearly with the probe beam through the polarizing beam splitter (PBS4) and is reflected through PBS5. By adjusting HWP5 and PBS5, the probe beam passing through the hot gas cell can be detected by ICCD or PD. In one case, the probe beam after the cell is sent to another 4f system with f9 and f10 and then is detected by an intensified charge-coupled device (ICCD, iStar 334T) to record the spatial intensity profile of CAB. In the other case, the probe beam is sent to a PD to record the pulse profile in the time domain.

4.   Experimental results and discussion
  • The results of spatial intensity distribution of CAB as shown in Fig. 2. The CAB can be visualized as the result of a one-dimensional Airy beam at a radial position being rotated around the center of the circle. Therefore, CABs could abruptly autofocus at the focal region. The autofocusing ability of CAB is verified in free space. The ICCD is initially placed at the focal plane of f10, and z1 represents the distance between the focal plane of f10 and the ICCD. It can be seen from Fig. 2(a) that the intensity distribution of CAB beam forms a hollow ring in the initial plane. To obtain Fig. 2(c), we calculated the normalized intensity distribution of the red dotted section located at z1 = 0 mm in Fig. 2(a). The light intensity at the center of CAB is zero and the intensity of the first main ring of the CAB takes up most of the light intensity. And the intensity profiles are shown in Fig. 2(c). As the CAB is transmitted, the size of the main ring gradually decreases. As the energy flows to the main ring, the transmission distance z1 increases. In Fig. 2(c), when z1 = 450 mm, the tallest and relatively narrow peak appears at the center of x-axis. And then, the peak at the center of x-axis becomes narrower when z1 increases from 450 mm to 700 mm. As shown in Fig. 2(e), the full width at half maximum (FWHM) of the autofocusing process of CAB in free space decreases from 1.07 mm to 0.36 mm, indicating that the CAB has almost become a solid spot.

    By placing an opaque rectangular obstacle at the focal plane of f10 to block most of the main ring of CAB, we demonstrate the self-healing property of CAB by moving the ICCD. Figure 2(b) shows the experimental results of the self-healing process of CAB for different z2 values, where z2 is the distance between the obstacle and ICCD. Because the obstacle is placed at z2 = 0 mm, the initial z2 is set to 25 mm from the image plane. Figure 2(d) is obtained by using the same method as Fig. 2(c). At z2 = 150 mm, the main ring of the spot has started to recover. As shown in Fig. 2(d), the beam energy at the initial position is blocked by the obstacle, causing the energy of the side rings to flow from the surrounding area to the blocking area. When z2 = 250 mm, a relatively high peak appears in the center of x-axis and a new spot begins to appear at the main ring position. As depicted in Fig. 2(f), with the increase in z2, the number of peaks at the center of x-axis increases. Moreover, the FWHM of the self-healing process of CAB in free space decreases from 1.58 mm to 0.29 mm, which indicates the main ring has almost become a solid spot. When z2 = 625 mm, the beam has basically reconstructed.

  • The corresponding time sequence of the storage of CAB is shown in Fig. 3(a), Before the storage, the control beam is switched on in advance to prepare most of the atoms to the state 5S1/2, F = 2. The spatial intensity profile of the input probe beam is coded with CAB. We set the duration of the input probe beam as 1 μs. When the probe pulse completely enters the Rb vapor cell, the control beam is immediately turned off. The photon states carrying by the probe beam are transferred into atomic collective spin excitation and stored in the cell. After a programmable time delay of ΔT, the control beam is switched on again to retrieve the probe pulse. In the meantime, the ICCD is activated by a trigger pulse to record the spatial intensity profile of the probe. In the experiment, we set the ICCD pulse duration with 6 μs to make sure that only the retrieved CAB signals can be collected.

    Figure 3(b) shows the normalized signal intensities before storage and after storage with different storage time t. When t increases from 0.2 μs to 1 μs, the intensity of the retrieved CAB decreases, leading to a corresponding decrease of the storage efficiency from 0.34 to 0.13, as shown in Fig. 3(c).

    To verify the property of the retrieved CAB, we investigate the autofocusing and self-healing process of the retrieved probe beam by changing t and the distance of the ICCD during the propagation. Figure 4 shows the experimental results of the autofocusing process of the retrieved CAB after the EIT-based storage with the different t and z1, where z1 is the distance between the plane of image and ICCD.

    Figure 4(a) shows the intensity distribution of the spatial intensity profile of CAB recorded by ICCD. As the propagation distance increases, the CAB’s power flows from the side rings to the main ring, and turns to a circular bright spot. By comparing with the cases of different storage time t, we can investigate that the autofocusing property of CAB after storage remains even suffering from atomic diffusion. As shown in Fig. 4(b), when t increases, the approximate profiles of the retrieved CABs remain. By fitting the data of the light field patterns at z1 = 700 mm for different t values, the intensity distribution curves of Fig. 4(b) can be obtained. The data in black, magenta, green, blue, and red correspond to t reaching 0.2 μs, 0.4 μs, 0.6 μs, 0.8 μs, and 1 μs, respectively. As depicted in Fig. 4(b), the atomic diffusion with increasing storage time has a great influence on the spatial distribution of CAB, which can be seen from the FWHM. We used the similarity S to quantitatively characterize the differences of the beam profiles. The real intensity distribution (not normalized) of the probe beam is used to calculate the value S, as presented in Tables 1 and 2. The expression of the similarity S is[49,50]

    where A and B are the grey-scale matrices of the two images before and after storage. The m and n correspond to the coordinates, respectively. Herein, we calculate both the similarity Stotal of total CAB and the Smain of its main ring. We select a square area of figures to calculate Smain and the area’s length and width are exactly tangent to the main ring. Furthermore, in our subsequent research, we will code the main ring with orbital angular momentum modes, which is useful for high-dimensional quantum information. Therefore, we focus on the evolution of the main ring of CAB. The similarities at different storage times ranging from 0.2 μs to 1 μs are illustrated in Table 1. As indicated by the Smain values in Table 1 and the intensity profiles of CAB in Fig. 4(b), at the same position z1, CAB’s shape remains unchanged during the process.

    As shown in Fig. 4(a), with increasing distance z1 for the same storage time t, the width of the main ring becomes narrower and the side lobe energy becomes lower, which indicates that most of the side lobe energy flows to the main lobe. The CAB becomes a solid spot and focuses at z1 = 700 mm.

    We further investigate the self-healing effect of retrieved CAB. Figure 5 shows the experimental results of the self-healing process of the retrieved CAB for different z2. As shown in Fig. 5, the energy of the secondary and other lobes flow to the main ring as the z2 increases.

    In the experiment, we use the same obstacle mentioned in 4.1 to block the main lobe, and observe the self-healing effect. It is clear to see that the main ring in the blocked area begins to be reborn at z2 = 150 mm. Moreover, with the same storage time t at the different z2 in Fig. 5(a), the blocked area’s light intensity increases, which means that the self-healing property of CAB can be maintained well after storage. Furthermore, when z2 = 375 mm, the main ring of CAB gradually becomes a bright spot at the center, which also depicts the autofocusing characteristic of CAB after storage.

    By fitting the data of the light field patterns at z2 = 625 mm for different t values, the intensity distribution curves of Fig. 5(b) can be obtained. The data in black, magenta, green, blue, and red correspond to t reaching 0.2 μs, 0.4 μs, 0.6 μs, 0.8 μs, and 1 μs, respectively. When t increases, the diffusion of atoms greatly affects the spatial distribution of CAB, leading to different FWHM values in Fig. 5(b). The similarities under different storage times are depicted in Table 2. According to the Smain values presented in Table 2 and the intensity profiles of CAB displayed in Fig. 5(b), at the same position z2, CAB’s shape remains unchanged during the propagation.

    The above results illustrate that the properties of the retrieved CABs remain preserved as storage time t increases, and the blocked parts are almost reborn after storage. The results further prove that the CAB can maintain its autofocusing and self-healing properties well after the storage process even suffering from atomic diffusion.

5.   Conclusion and perspectives
  • In conclusion, we have investigated the propagation properties and the optical storage of CAB with the Λ-type EIT-based storage scheme in a hot atomic vapor. The probe beam is coded with CAB’s wave packets in the transverse profile by using the SLM. The experimental results show that the autofocusing and self-healing effect of the retrieved CABs could be preserved well after storage. Furthermore, our research can be useful for high-dimensional spatial multi-modes storage. In addition, it also will play an important role in high-dimensional quantum communication to improve the channel capacities of quantum internet.

Figure (5)  Table (2) Reference (50)

Catalog

    /

    DownLoad:  Full-Size Img  PowerPoint
    Return
    Return