2024 Volume 33 Issue 10
Article Contents

Abeer S. Alnahdi, Taza Gul. Casson hybrid nanofluid flow over a Riga plate for drug delivery applications with double diffusion[J]. Chinese Physics B, 2024, 33(10): 104701. doi: 10.1088/1674-1056/ad624e
Citation: Abeer S. Alnahdi, Taza Gul. Casson hybrid nanofluid flow over a Riga plate for drug delivery applications with double diffusion[J]. Chinese Physics B, 2024, 33(10): 104701. doi: 10.1088/1674-1056/ad624e

Casson hybrid nanofluid flow over a Riga plate for drug delivery applications with double diffusion

  • Received Date: 09/03/2024
    Accepted Date: 30/06/2024
    Available Online: 01/09/2024
通讯作者: 陈斌, bchen63@163.com
  • 1. 

    沈阳化工大学材料科学与工程学院 沈阳 110142

  1. 本站搜索
  2. 百度学术搜索
  3. 万方数据库搜索
  4. CNKI搜索

Figures(5)  /  Tables(5)

Article Metrics

Article views(609) PDF downloads(1) Cited by(0)

Access History

Casson hybrid nanofluid flow over a Riga plate for drug delivery applications with double diffusion

Abstract: Casson fluid-mediated hybrid nanofluids are more effective at transferring heat than traditional heat transfer fluids in terms of thermal conductivity. Heat exchangers, cooling systems and other thermal management systems are ideal for use with Casson fluids. Precise control of the flow and release of medication is necessary when using Casson fluids in drug delivery systems because of their unique rheological properties. Nanotechnology involves the creation of nanoparticles that are loaded with drugs and distributed in Casson fluid-based carriers for targeted delivery. In this study, to create a hybrid nanofluid, both single-walled carbon nanotubes (SWCNTs) and multi-walled carbon nanotubes (MWCNTs) are dispersed in a Casson fluid with Fourier’s and Fick’s laws assumptions. The Casson fluid is suitable for various engineering and medical applications due to the enhancement of heat transfer and thermal conductivity by the carbon nanotubes. Our objective is to understand how SWCNTs and MWCNTs impact the flow field by studying the flow behavior of the Casson hybrid nanofluid when it is stretched against a Riga plate. The Darcy–Forchheimer model is also used to account for the impact of the porous medium near the stretching plate. Both linear and quadratic drag terms are taken into account in this model to accurately predict the flow behavior of the nanofluid. In addition, the homotopy analysis method is utilized to address the model problem. The outcomes are discussed and deliberated based on drug delivery applications. These findings shed valuable light on the flow characteristics of a Casson hybrid nanofluid comprising SWCNTs and MWCNTs. It is observed that the incorporation of carbon nanotubes makes the nanofluid a promising candidate for medical applications due to its improved heat transfer properties.

1.   Introduction
  • The unique properties of carbon nanotubes (CNTs), including their high strength, flexibility, electrical conductivity and thermal conductivity, have led to their widespread applications in various industries. The typical diameter of CNTs is between 1 nm and 50 nm and they can be up to several micrometers long.[1] The size of nanoparticles can vary based on the method of synthesis used and any post-processing steps that are performed. CNTs are employed to create lightweight and sturdy materials for aircraft and spacecraft components.[2,3] Improving the structural integrity of these components leads to better performance and fuel efficiency. The production of electronic devices, such as transistors, sensors and touch screens, involves the use of CNTs. Performance enhancement of electronic components is made possible by the excellent electrical conductivity and high electron mobility of CNTs. High-performance batteries and supercapacitors have been developed using CNTs, which with their high surface area and excellent electrical conductivity can increase energy storage capacity and efficiency.[4] The automotive industry utilizes CNTs to create lightweight and strong materials for vehicle components such as body panels, chassis and batteries. This contributes to the enhancement of fuel efficiency and vehicle performance.

    Drug delivery systems, tissue engineering and medical imaging are just a few of the biomedical applications that utilize CNTs. These applications are made possible by the biocompatibility of CNTs and their ability to penetrate cell membranes.[5] The addition of CNTs to a base fluid can enhance fluid properties because of their exceptional mechanical, thermal and electrical properties. Complex flow behavior can be described using the Casson fluid model, which is a non-Newtonian model that accounts for yield stress and fluid viscosity. Blood-borne drug carriers that target drug delivery systems are facilitated by the potential and widespread use of CNTs.[6] Their distinctive structure makes them a promising candidate for drug delivery applications due to their efficient loading and controlled release of therapeutic molecules. Furthermore, CNTs have been demonstrated to have low toxicity and are highly biocompatible, making them ideally suited for use in the bloodstream without causing harm to the body.[7,8] Targeted delivery to specific tissues or organs is made possible by the ability of CNTs to easily penetrate cell membranes; this minimizes side effects and improves treatment efficacy. The field of drug delivery and patient outcomes could be revolutionized by the use of CNTs as blood-borne drug carriers.[9]

    Riga plates are suitable for use in drug delivery systems due to their high surface area and unique properties. Hybrid nanofluids (HNFs) can improve the dispersibility and stability of the drug by combining with CNTs, improving therapeutic efficacy.[10] CNTs are excellent for drug delivery because of their high aspect ratio, high surface area and strong mechanical properties. By utilizing Riga plates in CNT-based nanofluids, the drug carrier system can be improved to release drugs and deliver them to specific tissues or organs with controlled release.[11,12] The use of Riga plates in drug carriers with CNT HNFs is a promising way to improve drug delivery systems and advance nanomedicine. New and improved drug delivery strategies for various medical applications could be developed through further research and development in this area.[13]

    The use of Darcy–Forchheimer model in drug delivery using CNT HNFs is crucial because it can improve the transport properties of drug-loaded nanofluids through porous media. Researchers can accurately predict drug transport characteristics and optimize the delivery process by using the Darcy–Forchheimer equation to describe the flow behavior of nanofluids in porous media.[14] In addition, the Darcy–Forchheimer model facilitates understanding of the connection between the CNTs and the drug molecules, providing insight into the diffusion and release processes within the nanofluid. The design of efficient drug delivery systems that can effectively target specific tissues or organs is crucial for improving therapeutic outcomes. The Darcy–Forchheimer model is indispensable for examining and optimizing the drug delivery procedure with CNT HNFs. The development of advanced drug delivery systems with improved efficiency and efficacy is assisted by a comprehensive understanding of transport phenomena.[15] In various physical systems, including environmental processes and industrial applications, the transport of energy and mass is crucial. Analysis of this transport frequently involves using a generalized form of the Fourier energy flux equation and Fick’s mass flux equation.[16] A temperature gradient leads to the flow of thermal energy through a material, as described by Fourier’s law of heat conduction. The heat transfer process is significantly modified by incorporating the effects of a magnetic field.[17,18] Magneto-thermal convection and magneto-enhanced thermal conductivity are two additional heat transfer mechanisms that can occur when a magnetic field is present, and can induce Lorentz forces. The transport of mass through a material due to a concentration gradient is governed by it, similar to Fick’s law of diffusion. Magnetophoresis can affect the mass transport process when there a magnetic field is present, as magnetic forces drive particle motion.[19,20] A complete understanding of energy and mass transport can be achieved when a magnetic field is combined with Fourier’s and Fick’s equations. Complex transport phenomena with important implications for various fields of study can arise from the interaction between thermal and concentration gradients and magnetic fields. Optimizing performance in a variety of technological applications, such as magnetic refrigeration systems and drug delivery devices, requires us to understand and control these transport processes.[21] Electromagnetic HNFs offer several advantages when used in drug delivery applications.[22] The ability to remotely control the flow of nanofluids through the body using an external magnetic field is a significant benefit. Targeted and precise delivery of drugs to specific sites in the body is made possible by this, resulting in a reduction in side effects and improved efficacy.[23] In addition, nanofluids contain electromagnetic particles that can serve as drug carriers, allowing for sustained release over time.[24,25] The use of electromagnetic HNFs for drug delivery can be challenging due to the need for stable and efficient flow through the body. In this study we address this challenge by proposing a Riga flow system. A microchannel that has grooves on the walls is used in a Riga flow system to create vortices that help with the mixing and dispersion of nanofluids. By improving the circulation and distribution of nanoparticles throughout the body, this system increases the effectiveness of the drug delivery process.[27] A Riga flow system can improve the flow of electromagnetic HNFs for drug delivery applications by controlling their size, concentration and surface properties. Researchers can ensure efficient drug delivery with minimal side effects by fine-tuning these parameters to improve the carriers’ stability, biocompatibility and drug-carrying capacity.[28]

    The significance of the homotopy analysis method (HAM) in solving fluid flow problems lies in its capacity to provide precise and efficient solutions to complex nonlinear equations.[29,30] This method can help researchers and engineers gain valuable insights into fluid behavior in different systems and optimize their designs for improved performance and efficiency. Additionally, the HAM can also contribute to the development of new analytical tools and approaches for studying fluid dynamics, which can contribute to advances in the field of fluid mechanics.[31,32]

    We highlight the novelty of this study based on the above discussion. The base fluid for drug delivery applications with a Casson fluid is an HNF made up of single-walled CNTs (SWCNTs) and multi-walled CNTs (MWCNTs). Drug delivery applications involve the assumption of electromagnetic flow on a Riga plate. Double diffusion is included in the Cattaneo–Christov thermal flux model, in contrast to the conventional Fourier equation. Both thermophoretic and Brownian motion are present in the Darcy–Forchheimer model.

2.   Mathematical formulation
  • To investigate drug delivery, the problem statement for a CNT HNF flow on a Riga plate is formulated. External electromagnetic forces are used to model the flow behavior of CNT nanofluids. This study focuses on the movement of a CNT HNF through a Casson base fluid over a Riga plate while under an electromagnetic field. The objective is to assess the impact of the electromagnetic field on the flow and heat transfer characteristics of the nanofluid, along with its corresponding velocity and temperature profiles. The Riga stretched plate velocity is uw(x) = ax along the x-axis. Tw and Cw are the wall surface temperature and concentration, respectively. The ambient temperature and concentration are T∞ and C∞, respectively. Fourier’s and Fick’s laws are also assumed in the model problem. Assumptions from the Darcy–Forchheimer model are employed to model the flow field. The flow field is restricted to laminar, preventing the effects of turbulence.

    Under the assumptions mentioned above, the basic governing equations are defined as

    where

    along with the boundary conditions

    Each component in the above equations is defined in the nomenclature in Appendix A.

    The relations between the thermophysical properties of the nanoparticles are given in Table 1 and the experimental values of these properties are given in Table 2.

    In Table 1, ϕ1 and ϕ2 represent the concentration of SWCNTs and MWCNTs, respectively. The subscripts nf and hnf are used to show the corresponding properties of the nanofluid and HNF, respectively. Introducing the similarity variables

    equations (1)–(7) transform as

    where

    with

    The parameters in the above transform equations are defined as

    Information about these parameters is given in the nomenclature.

    The skin friction coefficient (Cf), Nusselt number (Nu) and Sherwood number (Sh) are the physical quantities connected to the behaviors of drag force, heat transfer and mass transfer. The simplified form of the above physical quantities is

3.   HAM solution
  • In recent years, the HAM has become a significant mathematical tool for solving complex fluid flow problems. The approach is designed to find approximate solutions to nonlinear partial differential equations that are commonly encountered in fluid dynamics using a systematic and efficient approach. Nonlinear terms in equations are handled without linearization, a common limitation in many traditional analytical methods, and this is one of the key advantages of the HAM. A more precise representation of the flow dynamics is achieved in this way, particularly in cases where nonlinearities have a significant impact on the system’s behavior. The HAM’s versatility makes it a valuable tool for analyzing a wide range of fluid flow problems by allowing for the inclusion of various physical parameters and boundary conditions. The fluid’s behavior is influenced by multiple factors, which is why flexibility is crucial for investigating real-world scenarios. Furthermore, converging series solutions provided by the HAM are easily truncated to obtain precise approximations of the solutions. Compared with numerical techniques that may require significant computational resources, this method for solving fluid flow problems is computationally efficient.

4.   Results and discussion
  • Casson HNFs, specifically those based on CNTs, have received a lot of attention recently due to their potential use in drug delivery systems. CNTs are a popular choice because of their exceptional characteristics such as high aspect ratio, mechanical strength and thermal conductivity. This investigation studied the flow of CNT-based HNFs on a Riga stretching plate in the presence of an electromagnetic field and double diffusion, which introduces complexity with external forces affecting the flow behavior of HNFs. Drug delivery applications will benefit greatly from our findings because controlled flow of HNFs can be utilized to optimize the distribution and release of drugs in the body. Figure 1 shows the geometry of the proposed model and Fig. 2 the stepwise HAM solution. The delivery of therapeutic agents to specific target sites with high-precision drug delivery systems is modeled by tuning the parameters M, E, β, Ec, ϕ1 + ϕ2, γe, γm, α and Nt, Nb, Sc, χ, k1. The results obtained from changing parameters for the velocity, temperature and concentration profiles are displayed in figures and tables.

  • The Hartmann number α is a dimensionless number used to determine the relative importance of viscous forces compared with inertial forces in a fluid flow system, and its impact is displayed in Fig. 3(a). According to the results, the inclusion of CNTs in drug delivery systems leads to an enhancement of the velocity profile and improved drug delivery efficiency due to the increase in the value of the Hartmann number. The Casson fluid model is typically employed in drug delivery systems, and the influence of the Casson fluid parameter β can be seen in Fig. 3(b). When CNTs are used as carriers for drug delivery, the flow performance of the Casson fluid is enhanced even more. The velocity profile of the fluid flow is influenced by increasing β in the presence of CNTs. A more prominent shear-thinning behavior is observed when β is increased, and the fluid becomes less viscous at high shear rates. The result of this is faster flow rates and enhanced drug dispersion within the fluid. The velocity profile of drug transport through porous media is significantly affected by the parameter Fr, as shown in Fig. 3(c). The flow behavior within the porous medium is modified by CNTs, as well as enhancing permeability. The flow direction and velocity distribution within the medium are also altered by CNTs. Their unique structure and high aspect ratio result in a more uniform distribution f′(η) of the drug throughout the system. CNT-based HNFs display substantial variations in flow behavior when a magnetic field parameter M is applied, as shown in Fig. 3(d). Variations in fluid viscosity and rheological properties are caused by magnetic fields acting on HNFs. Magnetic fields generate magnetic forces that affect the dispersion and stability of CNTs in the nanofluid. The alignment and dispersion of CNTs are enhanced by increasing the magnetic field strength, which improves the flow characteristics of the nanofluid, enabling targeted delivery to specific tissues or organs by facilitating better control over the drug delivery process. However, the resistive behavior of magnetic parameters controls the fluid distribution. The flow behavior of CNT-based nanofluids is crucially influenced by the electric field parameter, as shown in Fig. 3(e). The movement of CNTs within the nanofluid is triggered by electro-kinetic effects caused by electric fields, such as electrophoresis and electro-osmosis. Enhanced dispersion and mobility are achieved by increasing the intensity of the electric field and strengthening the electro-kinetic forces acting on the CNTs. By promoting a uniform distribution of drug-loaded CNTs throughout the nanofluid, the efficiency of drug delivery is enhanced. Figure 3(f) displays the impact of the volume fraction ϕ1 + ϕ2 of CNTs on the drug delivery system. Drug delivery is affected by the presence of CNTs, which increase resistance to flow and control drug transport. With faster and more efficient delivery of drugs, the patient’s therapeutic outcome is enhanced.

  • In fluid flow, the Eckert number measures the ratio of kinetic energy to enthalpy through a dimensionless parameter. The Eckert number Ec is vital for the temperature distribution and the efficiency of drug delivery when using a CNT-based HNF for drug delivery applications, as displayed in Fig. 4(a). A higher ratio of kinetic energy to enthalpy is specified by an increase in the Eckert number, showing that convective heat transfer controls conductive heat transfer within the fluid flow. CNT-based HNFs place more stress on temperature distribution than thermal conductivity. To ensure the stability of therapeutic agents and prevent thermal degradation it is vital to control the temperature distribution when considering drug delivery applications. The temperature distribution within the nanofluid is influenced by the increased convective heat transfer caused by a higher Ec. The local temperature rise within the nanofluid can be reduced by enhanced cooling effects. Additionally, the dispersion of therapeutic agents within the nanofluid is enhanced by the increased convective heat transfer caused by a higher Ec. Optimizing Ec is vital for balancing the desired convective heat transfer effects with practical considerations such as energy consumption and system stability. The effectiveness of drug delivery processes is enhanced by a higher Ec, which promotes convective heat transfer and improves temperature control, drug stability and uniformity of drug distribution within the HNF. More efficient heat transfer throughout the system is attained by increasing the heat absorption and emission parameter χ, as shown in Fig. 4(b). Increasing χ raises the temperature of the HNF, which allows better transport of drug molecules through the system. The improved heat transfer results in better drug delivery rates and more precise drug release at the target site. Furthermore, the increased heat emission parameter χ ensures that the extra heat generated during the process is efficiently dissipated, keeping the drug molecules stable and preventing overheating. The movement of particles in a fluid due to a temperature gradient is known as thermophoresis, and the impact of the thermophoretic parameter Nt is shown in Fig. 4(c). The temperature profile for drug delivery applications is affected by the increase in the thermophoretic parameter in a Casson–CNT HNF flow. Enhanced heat transfer within the HNF is achieved by increasing Nt, which leads to a greater temperature difference across the fluid. Drug delivery applications benefit from this as it maintains the specific temperature range needed for drug stability or activation. The flow behavior of the Casson–CNT HNF is influenced by an increase in Nt, which results in changes in the velocity and temperature profiles within the flow.

    In this context, it is important to pay attention to the thermal relaxation time parameter γe displayed in Fig. 4(d). This is the time it takes for a system to return to thermal equilibrium after a temperature disturbance. The temperature profile of the Casson–CNT HNF flow is significantly affected by increasing the value of γe. Increasing γe results in a longer time for the system to reach thermal equilibrium after a temperature change. A stable temperature profile throughout the drug delivery process is achieved by the fluid’s slower response to changes in temperature.

  • The Schmidt number Sc is a dimensionless number that explains the difference between momentum and mass diffusivity in a fluid flow. The concentration profile of the flow is significantly affected by an increase in Sc in Casson–CNT HNFs used for drug delivery applications, as shown in Fig. 5(a). An increase in Sc results in an increase in the momentum diffusivity of the fluid relative to its mass diffusivity. The capacity of the fluid to transport momentum is greater than that for mass, which results in changes in the complete flow dynamics and temperature distribution within the system. The behavior of the HNFs is influenced by the concentration relaxation time parameter, particularly in terms of effectiveness of drug delivery. As the parameter γe increases, the concentration profile of the Casson–CNT HNF shows changes that have a direct impact on the drug delivery process, as shown in Fig. 5(b). The HNF responds more slowly to changes in the concentration gradients when this parameter increases. The drug delivery rate is slowed because the HNF may take longer to reach a steady-state concentration distribution.

    Casson–CNT HNFs employed in drug delivery applications depend on Brownian diffusivity to regulate their concentration profile. Figure 5(c) shows the changes in the concentration profile as the Brownian parameter Nb increases. The random motion of nanoparticles suspended in the fluid is enhanced by an increase in Brownian diffusivity. The nanoparticles are more effectively dispersed throughout the fluid medium due to increased agitation. Consequently, the concentration gradient between the drug-laden HNF and the adjacent environment becomes sharper, leading to faster diffusion of the drug molecules from the HNF to the targeted tissues or cells. The concentration profile is greatly influenced by the chemical reaction parameter k1 in Casson–CNT HNFs used for drug delivery applications (Fig. 5(d)). The rate of chemical reactions within the nanofluid system increases when the chemical reaction parameter is increased. The stability and release kinetics of the nanoparticles are affected by this. Drug release from the nanofluid carrier decelerates depending on the chemical reactions involved. Chemical reactions can lead to faster drug release by promoting the degradation of the nanoparticle shell. The rate of drug release is decreased by reactions leading to the formation of stable complexes.

  • Heat transfer and mass transfer are vital in drug delivery applications that utilize Casson–CNT HNFs as they influence the delivery system in numerous ways.

    Heat transfer maintains the stability and functionality of the HNF carrier, which is vital. Thermal fluctuations are common for Casson–CNT HNFs during transport. Operative heat transfer mechanisms stop temperature-induced degradation of drug molecules and ensure the stability of the carrier fluid by dissipating the heat generated by external factors within the HNF.

    Various parameters, such as the magnetic field M, electric field E, porous space parameters λ and Fr, Casson fluid parameter β and the modified Hartmann number α, have an impact on the flow of a CNT HNF over a stretched Riga plate. To optimize drug delivery, it is crucial to understand the effects of these parameters (i.e., β, λ, Fr, α, M and E) on the skin friction profile, as shown in Table 3.

    The flow behavior of CNT HNFs is greatly influenced by the magnetic field parameter M. The heat transfer and fluid flow characteristics of the nanofluid are improved by the addition of a magnetic field, resulting in changes in the skin friction profile. Higher skin friction values are caused by an increase in M, which indicates a higher resistance to fluid flow over the stretched Riga plate. This makes controlling the distribution of drugs within the body easier in drug delivery applications.

    The skin friction profile of CNT HNFs is also affected by the electric field parameter E. The friction value of the skin is changed by manipulating the flow behavior of the nanofluid using an electric field. The flow characteristics of the nanofluid are improved and the skin friction is reduced by increasing E, potentially leading to more efficient drug delivery. The same influence is observed for the modified Hartmann number α.

    The skin friction profile of CNT HNFs is influenced by the porous space parameter λ and the Forchheimer number Fr. The flow dynamics of the nanofluid are influenced by λ and Fr, leading to higher skin friction on the stretched Riga plate. Adjusting these parameters can lead to more effective drug delivery by controlling the distribution of drugs within the body.

    The skin friction profile of CNT HNFs is also influenced by the Casson fluid parameter β. The Casson model is frequently employed to depict the behavior of non-Newtonian fluids, and modifications to β influence the flow characteristics of the nanofluid. Increasing β can lead to higher skin friction values, indicating a higher resistance to fluid flow over the stretched Riga plate for drug delivery applications.

    The homogeneity of drug dispersion within the HNF is enhanced and flow behavior is ensured, resulting in optimized drug delivery. The diffusion of drug molecules from the HNF carrier to the targeted tissues is governed by mass transfer, which impacts the concentration profile and time course of drug release. Mass transfer is intertwined with the transport characteristics of Casson–CNT HNFs, which include diffusivity, permeability and convective transport. Drug-loaded nanoparticles are transported quickly and efficiently within the HNF with enhanced mass transfer, ensuring timely delivery to the desired sites of action.

    The numerical outputs for analyzing the heat transfer Rex−12Nux are displayed in Table 4. We see that Rex−12Nux is better for higher ϕ1 + ϕ2, χ, γe and Nt. An in-depth discussion of these parameters is given with regard to temperature distribution, with the impact on the heat transfer rate being analyzed in this table. The numerical data for Rex−12Shx for nanoparticles are shown in Table 5. We see that Rex−12Shx is greater with changes in Nt and γm while it is reduced for greater values of Nb and Sc

5.   Conclusions
  • The current research is focused on a theoretical analysis of Casson-based HNFs using a Riga device. CNTs are used as the solid materials in HNFs consisting of SWCNTs and MWCNTs. A comparative analysis is performed by varying the different embedded parameters. The solution to the problem is obtained using the HAM technique. The main findings are obtained as follows:

    The Eckert number Ec is vital in the temperature distribution and efficiency of drug delivery using CNT-based HNFs for drug delivery. By increasing Ec in HNFs, temperature distribution in the system becomes more efficient allowing targeting of the desired tissues in the drug delivery process.

    Casson–CNT HNFs can enhance the efficiency and effectiveness of drug delivery systems by increasing the heat absorption parameter χ.

    Overheating of the drug solution, that could potentially damage the drug molecules or the surrounding tissue, is prevented by increasing the thermal relaxation time parameter γe.

    Drug mixing and dispersion within the HNF improves delivery efficiency by enhancing the Schmidt number Sc.

    Boundary layers and stationary regions within the fluid flow are disturbed due to enhanced Brownian motion Nt.

    As the modified Hartmann number α increases, the flow rate of the HNF is improved but it decreases with larger values of Fr, β, λ and M. The results for the Hartmann number of the Riga actuator can be applied when high-speed flows are required.

    The skin friction of CNT HNFs flow on a stretched Riga plate for drug delivery applications is determined by the magnetic field, electric field, porous space and Casson fluid, all of which have significant roles to play in improving the performance of drug delivery.

Figure (5)  Table (5) Reference (32)

Catalog

    /

    DownLoad:  Full-Size Img  PowerPoint
    Return
    Return