Effect of matrix thermal properties on laser-induced plasma

  • Received Date: 08/05/2024
    Accepted Date: 19/06/2024
    Available Online: 01/10/2024
通讯作者: 陈斌, bchen63@163.com
  • 1. 

    沈阳化工大学材料科学与工程学院 沈阳 110142

  1. 本站搜索
  2. 百度学术搜索
  3. 万方数据库搜索
  4. CNKI搜索

Figures(4)  /  Tables(1)

Article Metrics

Article views(440) PDF downloads(3) Cited by(0)

Access History

Effect of matrix thermal properties on laser-induced plasma

Abstract: The matrix thermal properties have an important impact on laser-induced plasma, as the thermal effect dominates the interaction between ns-pulsed laser and matter, especially in metals. We used a series of pure metals and aluminum alloys to measure plasma temperature and electron density through laser-induced breakdown spectroscopy, in order to investigate the effect of matrix thermal properties on laser-induced plasma. In pure metals, a significant negative linear correlation was observed between the matrix thermal storage coefficient and plasma temperature, while a weak correlation was observed with electron density. The results indicate that metals with low thermal conductivity or specific heat capacity require less laser energy for thermal diffusion or melting and evaporation, resulting in higher ablation rates and higher plasma temperatures. However, considering ionization energy, thermal effects may be a secondary factor affecting electron density. The experiment of aluminum alloy further confirms the influence of thermal conductivity on plasma temperature and its mechanism explanation.

1.   Introduction
  • Laser-induced plasma has exotic and complex conditions, ranging in temperature, density, pressure, magnetic field, and electric field.[1] As a spectroscopic diagnostic method based on laser-induced plasma, the laser-induced breakdown spectroscopy (LIBS) technology has been widely used in various fields, such as metallurgy,[2,3] coal industry,[4] environment,[5] and energetic materials,[6] due to its unique advantages of rapid analysis time and little sample damage. However, the matrix effect reduces the accuracy of LIBS. Therefore, it is crucial to understand the correlation between the matrix physical properties and laser-induced plasma. For example, Sattar et al.[7] investigated the effect of hardness on the temperature and electron density of laser-induced plasma based on tungsten heavy alloys. The influence mechanism of ablation rate and laser-induced plasma was discussed from the perspectives of grain size and band gap. A surface hardness detecting method based on LIBS for alloys has been proposed. The thermal properties are particularly important in matrix effects, as the thermal effect play a dominant role in the entire process of interaction between ns-pulsed laser and matter. In other words, laser energy promotes the ionization process through thermal conduction. Many studies on the thermal properties of matrix effects focus on matrix temperature or the thermal properties of ambient gases. For example, Liu et al.[8] studied the effect of matrix temperature on fs-LIBS signals using a set of copper samples. The results indicate that the increase in sample temperature enhances the emission intensity. High temperature samples have higher plasma temperature and lower electron density. Yu et al.[9] used a series of gas mixtures composed of He, Ne, and Ar as the atmosphere for LIBS measurement of titanium alloy samples. The results indicated that changes in gas species mainly affect signal intensity, relative standard deviation, and total number density, rather than plasma temperature and electron density. A preliminary explanation was provided from the aspects of molecular weight, ionization energy, and thermal conductivity of the gas. Salloom et al.[10] discussed the correlation between the hardness of Ni–Cr–Nb alloy samples and the spectral line intensity ratio of LIBS spectra, plasma temperature, and electron density. Meanwhile, a semi-empirical formula between plasma temperature and thermal diffusivity was established based only on four samples.

    In this paper, we focus on the effect of matrix thermal properties on ns-pulsed LIBS by using a series of pure metals and aluminum alloys. We compared the Saha–Boltzmann plot method and the Boltzmann plot method to calculate the appropriate plasma temperature. Considering the comprehensive effects of thermal conductivity, specific heat capacity, and density, a good correlation between the heat storage coefficient of pure metals and plasma temperature was obtained, and its related mechanism was explained. Considering ionization energy, the effect of thermal properties on electron density was discussed. Finally, the above conclusion and internal mechanism were confirmed and detailed by observing the plasma temperature changes of a group of aluminum alloys with only different thermal conductivities.

2.   Experimental
  • In experiments, 8 different varieties of pure metals (>99% in weight) and 5 different varieties of 5000 series aluminum alloys with standard certificates provided by Jinan Zhongbiao Company were labeled as S1–S8 and A1–A5, respectively. Some important physical properties[11] of all samples are listed in Table 1, and their appearance is shown in Fig. 1(a).

    LIBS measurements were conducted using a self-made setup in Fig. 1(a). A Q-switched Nd: YAG laser (Newwave, USA) at 1064 nm with a pulse duration of 3 ns–5 ns and a repetition rate of 1 Hz–10 Hz is utilized as the ablation source. After getting reflected by the mirror (R), the laser pulse was focused on the surface of sample by the lens (L1, f = 50 mm) with a spot diameter of approximately 80 μm, and generates a tremendous laser power density over 100 GW⋅cm−2. After laser ablation, the emission spectra including the plasma continuum radiation and elemental atomic and ionic lines were acquired using a lateral signal collection module, which is composed of two lenses (L2, f = 50 mm, L3, f = 75 mm) and a fiber (d = 200 μm). The spectra were then analyzed using an optical fiber spectrometer. The gate of the spectrometer is controlled by a digital pulse delay generator (DG535, Stanford, USA) with the Q switch signal of laser pulse using as an external trigger source.

    For samples S1–S8, a four-channel spectrometer (regions from 180 nm to 690 nm, spectral resolution 0.1 nm, Avantes Avsdesktop USB2, Netherlands) installed with a COMS detector (2048 × 2048 pixels) was used for spectra collection. The laser energy and integration time were optimized at 24 mJ and 30 μs, respectively. The time delay of 1 μs from the laser light to the spectrometer starting the spectrum collection is optimized.

    For samples A1–A5, a four-channel spectrometer (regions from 181 nm to 655 nm, spectral resolution 0.07 nm, Avantes Avsdesktop USB3, Netherlands) was used. The laser energy, integration time and delay time were at 16 mJ, 30 μs, and 1 μs, respectively.

    Spectra were collected from 10 repeated pulses at 25 selected positions on the surface of each sample. To reduce the impact of surface differences, such as oxide layer on surface, 5 ablation pulses were performed as pre-pulse at each of the 25 selected points before spectral collection. And as the result, any lines of oxygen were not observed in the collected spectra. Finally, a total of 250 sets of spectral data were collected from each sample.

    The ablation volumes are calculated by measuring the post-ablation surface contours through a step profile, with the results presented in Table 1.

3.   Result and discussion
  • In laser-induced plasma, the Stark broadening caused by electron radiation dominates the spectral line broadening. The electron density is related to Stark broadening, so it can be estimated by

    where ne is the electron density, Δλ1/2 is the full width at half maximum of spectral line, and w is the electron collision parameter.[12]

    When the plasma satisfies the condition of local thermodynamic equilibrium, the particles on the energy level obey the Boltzmann distribution law. The spectral line intensity is related to the emissivity between energy levels. The plasma temperature can be estimated using Boltzmann plot of atomic spectral lines, as shown below:

    where T is the plasma temperature, λ is the wavelength of the line, Iλ is the intensity of spectral line, gk is the statistical weight for the upper energy level, Aki is the transition probability, kB is the Boltzmann constant, and Ek is the energy of the upper energy level.[13]

    The plasma temperature can also be estimated using Saha–Boltzmann plot of both atomic and ionic spectral lines, as shown below:

    Unlike atomic spectral lines, ionic spectral lines need to be corrected using

    where m is the electron mass, h is the Planck constant, EIP is the ionization energy of element and ΔE is the corresponding plasma interaction correction of ionization energy.[14] Herein, the electronic density ne is calculated through Hα 656.28 nm using Stark broadening method. The atomic and ionic spectral lines used in Boltzmann method and Saha–Boltzmann method, as well as their spectroscopic data Aki, gk, Ek, EIP, and ΔE were all retrieved from the spectra database of the National Institute of Standards and Technology (NIST).[15]

    As shown in Fig. 1(b), the plasma temperatures of pure metals were calculated using Boltzmann plot method and Saha–Boltzmann plot method, as well as the R2 of the corresponding linear fitting results. The plasma temperatures calculated by the two methods are different, but Saha–Boltzmann plot method shows better performance in fitting. For samples S1–S8, compared to Boltzmann plot method, Saha–Boltzmann plot method usually has a higher R2 maintained above 0.9. Due to the simultaneous utilization of atomic and ionic spectral lines of the same element, Saha–Boltzmann plot method achieves a wider range of upper energy levels, thereby improving the accuracy of temperature measurement. Therefore, the plasma temperature calculated by Saha–Boltzmann plot method was chosen for subsequent analyses of pure metal samples.

    The temperature of the material increases rapidly in the process of continuous absorption of laser energy. The distribution of temperature with time at different depths satisfies

    where T is the temperature, x is the depth from the surface, κ is the thermal conductivity, Cp is the heat capacity, ρ is the density, α is the absorption coefficient, and I is the internal heat source.[16]

    In the interaction between laser and material, thermal conductivity, specific heat capacity, and density jointly affect the thermal diffusion on the material surface, thereby affecting the role of laser energy in the core reaction zone, and reflected in the laser-induced plasma. Figures 2(a), 2(b), and 2(c) respectively show the direct relation between laser-induced plasma temperature and the matrix thermal conductivity, specific heat capacity, and density of eight pure metal samples. No significant correlation was observed as the maximum R2 was less than 0.4. Due to the insufficient number of samples, the simultaneous differences in various matrix properties hide this correlation. Considering that the loss of laser energy is not limited to thermal diffusion, and the energy remaining on the local surface has a more significant impact on the plasma temperature. Herein, the thermal storage coefficient S is introduced, which can characterize the ability of materials to store heat in local areas, involving the thermal conductivity, heat capacity, and density of the matrix, as shown below:

    where τ is the harmonic period, usually taken as 24 hours.[17]

    Figure 2(d) shows the variation of the laser-induced plasma temperature with the heat storage coefficient. It can be considered that the laser-induced plasma temperature has a negative linear correlation with the heat storage coefficient of the matrix, as R2 is greater than 0.95. This means that the plasma temperature is negatively correlated with the thermal conductivity, specific heat capacity, and density of the matrix. When the ns-pulsed laser is focused on the surface of the sample, metal materials with lower thermal conductivity dissipate less energy through thermal diffusion. Then, larger laser energy deposits in smaller local areas, leading to increased ablation. For materials with lower specific heat capacity and density, melting and vaporization within a local range on the surface require less laser energy. Therefore, it will lead to higher ablation efficiency and faster temperature rise. Considering the above points, there is less laser energy used for thermal diffusion or melting and vaporization for metal materials with low heat storage coefficients. So, more laser energy can be absorbed by subsequent laser-induced plasma, ultimately leading to a higher temperature of laser-induced plasma.

    In Fig. 3(a), there is a weak negative correlation between plasma electron density and the heat storage coefficient, with an R2 of only 0.618. However, this does not invalidate the previous interpretation of the role of thermal properties in the LIBS matrix effect. In addition to the thermal effect of laser energy in the matrix, another important factor to be considered is the ionization energy of matrix elements. The electron density depends on the absorption of laser energy by the plasma, while ionization energy greatly affects the plasma shielding effect.[18] The secondary or higher ionization inside the plasma is much lower than that of first ionization and can be ignored to some extent, so the first ionization energy should be significantly correlated with the electron density of laser induced plasma. However, the negative correlation between electron density and the first ionization energy is also at a relatively low level, as shown in Fig. 3(b), where R2 is only 0.523. The low heat storage coefficient increases plasma electron density by the enhancement of the ablation rate and mass, but the combined effect with other matrix parameters (such as the first ionization energy) weakens the direct manifestation of this correlation when the sample size is insufficient. These indicate that the influence of laser absorption or shielding on plasma electron density takes into account the contribution of more parameters, while thermal properties may be a secondary factor. A more comprehensive and accurate model needs to be established to explain the impact of various matrix parameters, including thermal properties, on the complex evolution process of plasma.

  • Samples A1–A5 were used for further discussion and confirmation of the correlation between the thermal conductivity of the matrix and the laser-induced plasma. Taking sample A1 as a representative, figure 4(a) shows the typical LIBS spectrum of this type of aluminum magnesium alloy. The determination of spectral lines was based on the NIST spectral database.[15] As shown in Table 1, 5 different 5000 series aluminum alloys have similar densities and specific heat capacities, but differ greatly in thermal conductivity, highlighting the effect of metal thermal conductivity on laser-induced plasma. Herein, the Boltzmann plot method was used to evaluate the plasma temperature based on Al atomic spectral lines, as all fits in A1–A5 already have R2 exceeding 0.93.

    Figure 4(b) shows a negative linear correlation between the laser-induced plasma temperature and the thermal conductivity of aluminum alloys, with an R2 of 0.979, which is consistent with the interpretation of the thermal conductivity obtained in laser-induced plasma of pure metals. In metal materials, the energy transfer between free electrons plays the major role in thermal conduction. In the temperature field, high temperature electrons will move rapidly and exchange energy with low temperature electrons through collisions.[19]

    As shown in Eq. (6), when the heat capacity, mass density, and absorption coefficient are similar, materials with lower thermal conductivity dissipate less energy during thermal conduction, which means that the energy transferred to new free electrons through collisions will be reduced. At the same time, more laser pulse energy will be accumulated in the small local areas on the surface and be absorbed by free electrons, resulting in smaller ablation range and higher energy density. In this way, more energy is absorbed by fewer free electrons and electrons obtain greater kinetic energy. Therefore, more materials are more likely to reach the plasma state generated by melting and vaporization. The initial temperature and ionization degree of the plasma generated during this process are relatively high, ultimately leading to a higher plasma temperature.

4.   Conclusion and perspectives
  • In conclusion, we used a group of samples, including pure metals and aluminum alloys, to investigate the effect of matrix thermal properties on ns-pulsed laser-induced plasma. The plasma temperature and electron density were determined by spectroscopy and were correlated with the matrix properties, including thermal conductivity, specific heat capacity, density, and first ionization energy. In the pure metal experiment, heat storage coefficients calculated from thermal conductivity, heat capacity, and density were introduced, and a significant negative correlation was observed with plasma temperature. These observations are explainable considering that metal materials with low thermal conductivity and low specific heat capacity require less laser energy for thermal diffusion or melting and vaporization, resulting in higher ablation rates and higher plasma temperatures. The weak negative correlation between plasma electron density and heat storage coefficient leads to an interpretation that thermal properties play a secondary role in the matrix effect of laser absorption or shielding on plasma electron density. In the experiment of aluminum alloys, the direct correlation between thermal conductivity and plasma temperature provides a more detailed discussion, strongly confirming the conclusion of thermal effects in pure metals. Overall, this also reveals the impact of thermal effects on LIBS spectral acquisition and is expected to provide a new approach for measuring the thermal properties of unknown metals.