2024 Volume 33 Issue 11
Article Contents

Yuan-Yuan Wu, Yun-Hui He, Yue-Chun Jiao, Jian-Ming Zhao. Microwave field sensor based on cold cesium Rydberg three-photon electromagnetically induced spectroscopy[J]. Chinese Physics B, 2024, 33(11): 113201. doi: 10.1088/1674-1056/ad7579
Citation: Yuan-Yuan Wu, Yun-Hui He, Yue-Chun Jiao, Jian-Ming Zhao. Microwave field sensor based on cold cesium Rydberg three-photon electromagnetically induced spectroscopy[J]. Chinese Physics B, 2024, 33(11): 113201. doi: 10.1088/1674-1056/ad7579

Microwave field sensor based on cold cesium Rydberg three-photon electromagnetically induced spectroscopy

  • Received Date: 02/07/2024
    Accepted Date: 28/08/2024
    Available Online: 01/10/2024
通讯作者: 陈斌, bchen63@163.com
  • 1. 

    沈阳化工大学材料科学与工程学院 沈阳 110142

  1. 本站搜索
  2. 百度学术搜索
  3. 万方数据库搜索
  4. CNKI搜索

Figures(6)

Article Metrics

Article views(533) PDF downloads(3) Cited by(0)

Access History

Microwave field sensor based on cold cesium Rydberg three-photon electromagnetically induced spectroscopy

Abstract: We present the electromagnetically induced transparency (EIT) spectra of cold Rydberg four-level cascade atoms consisting of the 6S1/2 → 6P3/2 → 7S1/2 → 60P3/2 scheme. A coupling laser drives the Rydberg transition, a dressing laser couples two intermediate levels and a weak probe laser probes the EIT signal. We numerically solve the Bloch equations and investigate the dependence of the probe transmission rate signal on the coupling and dressing lasers. We find that the probe transmission rate can display an EIT or electromagnetically induced absorption (EIA) profile, depending on the Rabi frequencies of the coupling and dressing lasers. When we increase the Rabi frequency of the coupling laser and keep the Rabi frequency of the probe and dressing laser fixed, flipping of the EIA to EIT spectrum occurs at the critical coupling Rabi frequency. When we apply a microwave field coupling the transition 60P3/2 → 61S1/2, the EIT spectrum shows Autler–Townes splitting, which is employed to measure the microwave field. The theoretical measurement sensitivity can be 1.52 × 10−2 nV⋅cm−1⋅Hz−1/2 at the EIA–EIT flipping point.

1.   Introduction
  • The electromagnetically induced transparency (EIT) of Rydberg three-level atoms has been widely investigated due to its non-destructive detection of Rydberg levels and potential application in microwave measurement. Rydberg atoms, with principal quantum number larger than 10, exhibit unique properties,[1,2] such as high polarizability (∼ n*7, with n* the effective quantum number) and a large microwave transition dipole moment (∼ n*2), making them extremely sensitive to the external electric field.[3] Rydberg EIT exhibits Autler–Townes (AT) splitting[4,5] or Stark shifts[6–8] when an external field is applied that interacts with the Rydberg atom; this has been employed to realize calibration-free microwave field measurements covering a wide frequency range from about 1 GHz to 1 THz,[9–12] including measurement of the radio-frequency field strength,[13–15] polarization[16,17] and phase,[18–20] as well near-field terahertz imaging[12] and sub-wavelength microwave imaging.[21,22] When using the Rydberg EIT–AT splitting method as a field sensor, the sensitivity of a Rydberg atom can be 30 μV⋅cm−1⋅Hz−1/2.[9] With implementation of the Rydberg atomic heterodyne technique,[17,23,24] the sensitivity of Rydberg atom receivers has been significantly enhanced to 55 nV⋅cm−1⋅Hz−1/2[18] and later to 30 nV⋅cm−1⋅Hz−1/2.[25]

    All the above applications are based on the Rydberg three-level two-photon EIT scheme, and the related EIT resonance linewidth is limited by the Doppler mismatch between the probe and coupling lasers. The four-level three-photon scheme can effectively cancel the Doppler mismatch and decrease the EIT linewidth. Furthermore, this scheme requires three semiconductor lasers, which are cheap and simple structures with high stability. Four-level spectroscopy demonstrates the feature of flipping of electromagnetically induced absorption (EIA) to EIT, which can be employed to detect the microwave field. Four-level EIT has already been investigated.[26–29] Thaicharoen et al.[28] theoretically investigated EIT and EIA spectroscopy and microwave-field sensing with a Rb vapor cell. Nikunjkumar et al.[29] used a cesium four-level atom with the 9S intermediate state to obtain an EIT linewidth of 39 kHz. Their results showed that for a probe Rabi frequency larger than three-fifths of the coupling Rabi frequency the EIA flips to EIT. The three-photon system can lead to narrower resonances; however, this does not necessarily translate directly to optimal conditions for field sensitivity.

    In this work, we focus on the four-level cold cesium atomic system formed with the 6S1/2 → 6P3/2 → 7S1/2 → 60P3/2 scheme. We numerically solve the Bloch equation and investigate the EIT and EIA effects of four-level atoms. Cold atoms with a temperature of ∼ 100 μK have a long coherence time, yielding narrow-linewidth EIT. The dependence of EIT transmission on the Rabi frequency of the dressing and coupling lasers is investigated. The EIT transmission signal decreases with coupling Rabi frequency and converts to an EIA signal at critical coupling Rabi frequency, at which point the probe transition is sensitive to the microwave field; this can be used to measure the microwave field with improved sensitivity.

2.   Theoretical model
  • We consider a four-level ladder cesium atom with a ground state |6S1/2〉, two intermediate states |6P3/2〉 and |7S1/2〉 and Rydberg state |60P3/2〉 (see Fig. 1). The first photon of an 852 nm laser, a weak probe laser, drives the lower transition |6S1/2〉 → |6P3/2〉 with a detuning Δp and a Rabi frequency Ωp/2π = 3 MHz. The second photon of a 1470 nm laser, a dressing laser, couples the middle transition |6P3/2〉 → |7S1/2〉 with a Rabi frequency Ωd and fixed detuning Δd = 0 MHz. The third photon of a 780 nm laser, a coupling laser, achieves Rydberg excitation of the up transition |7S1/2〉 → |60P3/2〉 with detuning Δc and a Rabi frequency of Ωc.

    The Hamiltonian of a four-level system can be expressed as

    where Δ1, Δ2 and Δ3 can be written as

    Considering the decay of the system, the Lindblad equation is used to describe the evolution of the density matrix ρ as follows:

    where ℒ is the Lindblad operator that indicates the decay processes of atoms

    For convenience, {|1〉, |2〉, |3〉, |4〉} is used as the state basis to represent {|6S1/2〉, |6P3/2〉, |7S1/2〉, |60P3/2〉}. ρkj is the density matrix element with k,j ∈ {1,2,3,4}. Γi (i = 2,3,4) denotes the spontaneous decay rate of the |i〉 state. Here the dephasing effects due to the laser linewidth, transition broadening and collisions between atoms are not considered. For cesium atoms, we take the decay rates Γ2 = 2π × 5.22 MHz, Γ3 = 2π × 3.29 MHz and Γ4 = 2π × 0.76 kHz, respectively. The weak probe laser is locked to the transition |1〉 → |2〉, the dressing laser is locked to the resonant transition |2〉 → |3〉 and the strong coupling laser scans over the Rydberg transition |3〉 → |4〉, then we set Δd = 0 MHz in calculations.

    For the atomic system, the probe transmission rate is defined as ℛ = P/Pin = exp(−αL), where Pin is the probe power before the cell and L is the length of our atomic cloud. The parameter α = 2π Im (χ)/λp is the absorption coefficient of the probe laser based on Beer’s law, with χ the susceptibility of the medium. The susceptibility χ is written as[30]

    where μ12 is the dipole moment of the transition |1〉 → |2〉, Ep is the amplitude of the probe laser field, ε0 is the vacuum permittivity, N is an atomic density and ρ12 is the density matrix element in Eq. (3). The average atomic density is N = 1010 cm−3 at temperature T≃ 100 μK for a typical cold cloud of L = 2.5 mm, the corresponding velocity of the atoms is a few cm⋅s−1 leading to negligible Doppler broadening. Note that when the system is at room temperature (T = 300 K), the Doppler broadening and shift can no longer be neglected. The laser direction and Doppler shifts for probe and coupling and dressing lasers should be included.

3.   Results and discussion
  • We numerically solve Eq. (3) and obtain ρ12 and the probe transmission rate ℛ. Here we keep Δp = 0 MHz and Δd = 0 MHz and scan the coupling laser frequency over the Rydberg transition to investigate the probe transmission rate as a function of the dressing and coupling Rabi frequencies. If the probe transmission rate is positive, the atomic system is in the EIT regime, whereas if the probe transmission rate is negative the atomic system is in the EIA regime.

  • In this section, we investigate the dependence of the probe transmission rate on the Rabi frequency of the dressing laser Ωd and keep the Ωp/2π = 3 MHz and Ωc/2π = 1 MHz. Figure 2 presents the calculation of the probe transmission rate for Ωd/2π = 10 MHz (Fig. 2(a)) and Ωd/2π = 30 MHz (Fig. 2(b)). It is seen that the probe transmission rate shows that the EIT spectra and EIT signal are about three times larger for Ωd/2π = 10 MHz than for Ωd/2π = 30 MHz. In order to understand the variation of the EIT signal, we perform a series of calculations for the range Ωd/2π = 0.5–50 MHz. Figure 3(a) plots the EIT spectra as a function of the coupling detuning Δc and the dressing laser Rabi frequency Ωd, with Ωp/2π = 3 MHz and Ωc/2π = 1 MHz. Figure 3(b) displays the EIT transmission and linewidth, extracted by Lorentz fitting to the spectra, as a function of Ωd. It is found that the EIT transmission rate increases with the Rabi frequency of the dressing laser up to a maximum when Ωd/2π = 10.52 MHz. When we further increase Ωd, the EIT transmission rate begins to decrease. In addition, the EIT linewidth decreases with Ωd; the linewidth can be 0.25 MHz at Ωd/2π = 40 MHz.

  • We next investigate the dependence of the probe transmission rate on the Rabi frequency of the coupling laser Ωc and keep Ωp/2π = 3 MHz and Ωd/2π = 10 MHz. Figures 4(a) and 4(b) present the probe transmission rate spectra as a function of coupling laser detuning for Ωc/2π = 1 MHz and Ωc/2π = 7 MHz, respectively. It is interesting to see that the EIT spectrum for Ωc/2π = 1 MHz of Fig. 4(a) flips to the EIA spectrum for Ωc/2π = 7 MHz of Fig. 4(b). This phenomenon can be explained by the fact that the coherence between the excited state |3〉 and the Rydberg state |4〉 is broken due to the strong coupling of the coupled laser, which results in an increase in the absorption encountered by the probe laser as it passes through the medium, forming the EIA spectrum.[27,31]

    To explain what happens when the coupling Rabi frequency increases and to explore the flip point, we carried out more calculations of probe transmission rate spectra by varying the Rabi frequency of the coupling laser from Ωc/2π = 0.5 MHz to 15 MHz while keeping Ωp/2π = 3 MHz and Ωd/2π = 10 MHz fixed. From the EIT or EIA spectra, we extracted the peak amplitude and plotted it as a function of the coupling Rabi frequency, as shown by the blue solid line in Fig. 4(c). It is found that the probe transmission displays an EIT spectrum when Ωc/2π < 2.61 MHz but an EIA spectrum when Ωc/2π > 2.61 MHz. The Rabi frequency of the coupling laser Ωc/2π = 2.61 MHz is the critical point at which EIT flips to EIA for cesium four-level atoms. To verify the ubiquity of EIT–EIA flipping, the Rabi frequency of the dressing laser Ωd/2π = 30 MHz was changed and similar calculations to Figs. 4(a) and 4(b) were performed. The probe transmission rate amplitude as a function of Ωc is plotted by the orange dash-dotted line in Fig. 4(c). Note that (i) the probe transmission rate amplitude is smaller for large Rabi frequencies of the dressing laser (Ωd/2π = 30 MHz) than for small ones (Ωd/2π = 10 MHz). This may be because the larger dressing field leads to decoherence of the four-level atomic system, which agrees with the calculation in Fig. 3(b). (ii) The probe transmission rate spectra display a similar phenomenon of EIT–EIA flipping when the Rabi frequency of the coupling laser Ωc is increased and the critical flipping point appears at about the same point. The inset to Fig. 4(c) displays a zoomed-in view of the critical point marked with a shaded square, from which we extract the critical point as 2.38 MHz for Ωd/2π = 30 MHz.

    Detailed analysis of the theoretical calculations for parameters Ωp, Ωd and Ωc indicates that small changes in Ωp, large changes in Ωc or even larger changes in Ωd can flip the EIA and EIT lines. Next, we consider the flipping of EIA to EIT by changing Ωc as an example and explore microwave measurements based on four-level atoms.

  • Rydberg three-level EIT in microwave fields can split and form EIT–AT splitting spectra, which are employed to realize calibration-free microwave measurement.[9] For the four-level EIT in this work, the EIT signal also displays AT splitting when we apply a microwave field coupling the Rydberg transition (see Fig. 5(b)), where the microwave field (Ωmw) couples the Rydberg transition |60P3/2〉 → |61S1/2〉. We solve the matrix density equation of a five-level atom with Γ5/2π = 0.71 kHz. Figure 5(c) presents the calculated EIT spectra with and without a microwave field, in which the field-free probe transmission rate spectrum displays the EIT profile for Ωp,d,c/2π = 3 MHz, 10 MHz and 1 MHz. The probe transmission rate displays the typical EIT spectrum in the absence of a microwave field and EIT–AT splitting with a microwave field of Ωmw/2π = 2 MHz. The measured EIT–AT splitting is proportional to the microwave Rabi frequency Ωmw, which is similar to three-level EIT[9] and can also be used to measure the microwave field.

    As mentioned above, there is a critical point for flipping EIA to EIT for the four-level atom (see Fig. 4(c)). The simulation shows that the flipping of EIA to EIT occurs when a weak microwave field is applied near the critical parameter with Ωp,d,c/2π = 3 MHz, 10 MHz and 2.65 MHz, as shown in Fig. 6(a). It is seen that the probe transmission rate displays the EIA profile in the absence of a microwave field (blue dashed line in Fig. 6(a)) and the EIT profile when a microwave field is applied (yellow dot-dashed and orange solid lines of Fig. 6(a) for Ωmw/2π = 0.5 MHz and 0.05 MHz, respectively). When we further increase Ωmw, the EIT signal shows AT splitting, as shown in Fig. 5(c).

    To explore the evolution of EIA to EIT near the critical point, a series of calculations were done by changing the microwave field Ωmw/2π = 0–10 MHz and extracting the EIT or EIA amplitude. Figure 6(b) displays the peak of the probe transmission rate ℛ as a function of Ωmw. ℛ shows EIA in the absence of a microwave field; the EIA signal decreases when a microwave field is applied and disappears when Ωmw/2π = 0.0049 MHz, meaning that the EIA spectrum converts to an EIT spectrum. When Ωmw/2π = 0.18 MHz, the amplitude of EIT reaches a maximum.

    It is worth noting that the probe transmission rate includes two regimes, one is the EIA–EIT flipping and EIT increasing regime and the other is the EIT decreasing regime. The latter is also the EIT–AT regime, where the probe spectra show EIT–AT splitting as in Fig. 5(c), similar to the three-level atom, and can be used to measure the microwave field based on EIT–AT splitting.[9] For the first regime, the probe transmission rate displays flipping of EIA to EIT in a very weak microwave field, where variation of the probe transmission rate is very sensitive to the microwave field; this can be employed to precisely measure or sense the microwave field. The inset of Fig. 6(b) shows an enlargement of the flipping point.

    Next, we take Fig. 6(b) as an example to illustrate weak microwave measurement based on EIA–EIT flipping. As stated above, near the EIA–EIT flipping point the gradient of the probe transmission rate is huge. The measurement of microwave field transfer to measure the variation of probe transmission rate (Δℛ) when a microwave field is applied, as shown in the inset of Fig. 6(b). The minimum measurable field depends on the minimum change that can be detected in the probe transmission rate (Δℛmin), which is limited by the noise of the system. For an atomic system interacting with the laser beam, the noise limitation is the shot noise of probe beam. The minimum field, Emin, can be obtained when Δℛmin becomes indistinguishable from the noise. The shot noise is usually written as σ=n (n is the photon number of probe laser).[32] The noise power for a collection time of 1 s then reads

    where h is Planck’s constant and ν is probe laser frequency. When the probe transmission change ΔPout is equal to the noise power ΔPout = PinΔℛmin = Pnoise, the corresponding transmission is the minimum resolvable probe transmission rate Δℛmin=Pnoise/Pin=hν/Pin. The minimum microwave field that can be detected is written as

    where Ωmwmin is the minimum microwave Rabi frequency, and can be obtained from Δℛmin and the maximum slope (Δℛ/ΔΩmw)max. For the probe laser Rabi frequency we used, Δℛmin = 1.008 × 10−6, the minimum measurable microwave Rabi frequency was Ωmwmin/2π = 0.245 Hz, corresponding to a theoretical sensing sensitivity of S = 1.52 × 10−2 nV⋅cm−1⋅Hz−1/2 for a measurement time of 1 s, which is two orders of magnitude better than the measurement value of 5.1 nV⋅cm−1⋅Hz−1/2.[33] However, it should be noted that the minimum detected microwave field is limited by the shot noise of the probe laser, which can be decreased by decreasing the power of the probe laser. Weak laser power may lead to a low signal-to-noise ratio of the EIT signal. In the experiments there must be a balance between the probe laser shot noise and the signal-to-noise ratio of the probe transmission rate spectrum. In addition to the shot noise of probe laser, the noise of the coupling laser and frequency fluctuations, etc., also increase the noise limit Pnoise, making sensitivity of the actual measurement lower than suggested by calculations.

    The cold atomic system studied in this work has a long coherence time, resulting in narrow linewidth EIT spectroscopy, and the minimum measurable field and sensitivity are two orders of magnitude better than in a vapor cell with the same level scheme. Figure 5(a) presents an experimental protocol for measuring the microwave field, where the cesium atoms are laser-cooled and trapped in a standard magneto-optical trap and the photodiode detector measures the three-photon EIT and EIA spectra and also senses the microwave field.

4.   Conclusion
  • In this work, we investigated the quantum effect of a laser interacting with a cesium four-level cascade atom in theory. By numerically resolving the Hamiltonian equation, we obtained the probe transmission rate as a function of the coupling laser detuning for different Rabi frequencies of Ωp,d,c and found that probe transmission rate spectra can be converted from EIA to EIT at critical parameters of laser Rabi frequency. By analyzing the probe transmission rate, we extract the critical point. In both the EIT and EIA regimes, the probe transmission rate can lead to AT splitting when we apply a microwave field coupling the Rydberg transition, for example the |60P3/2〉 → |61S1/2〉 transition in this work, and the corresponding AT splitting is proportional to the microwave Rabi frequency (see Fig. 5(c)), which is used to measure the microwave field. Importantly, in the regime of EIA–EIT flipping, the EIA signal is converted to an EIT signal with a huge slope when a weak microwave field is applied (see Fig. 6(b)). The EIA–EIT flipping and the huge slope are very sensitive to the microwave field, therefore providing a method to detect the microwave field with high sensitivity. The minimum microwave field obtained depends on the minimum change in the probe transmission rate, and is limited by the shot noise. This work was done within cesium atoms with a temperature of 100 μK, and could easily be extended to the room-temperature case with the Doppler shift included. The investigations in this work are significant for Rydberg atom-based microwave measurement and field sensors.

Figure (6)  Reference (33)

Catalog

    /

    DownLoad:  Full-Size Img  PowerPoint
    Return
    Return