2024 Volume 33 Issue 12
Article Contents

Kai Wen, Huijin Chen, Xu Yan, Zejian Ren, Chengdong He, Elnur Hajiyev, Preston Tsz Fung Wong, Gyu-Boong Jo. Apparatus for producing single strontium atoms in an optical tweezer array[J]. Chinese Physics B, 2024, 33(12): 120703. doi: 10.1088/1674-1056/ad84d0
Citation: Kai Wen, Huijin Chen, Xu Yan, Zejian Ren, Chengdong He, Elnur Hajiyev, Preston Tsz Fung Wong, Gyu-Boong Jo. Apparatus for producing single strontium atoms in an optical tweezer array[J]. Chinese Physics B, 2024, 33(12): 120703. doi: 10.1088/1674-1056/ad84d0

Apparatus for producing single strontium atoms in an optical tweezer array

  • Received Date: 20/08/2024
    Accepted Date: 26/09/2024
    Available Online: 01/12/2024
通讯作者: 陈斌, bchen63@163.com
  • 1. 

    沈阳化工大学材料科学与工程学院 沈阳 110142

  1. 本站搜索
  2. 百度学术搜索
  3. 万方数据库搜索
  4. CNKI搜索

Figures(5)  /  Tables(1)

Article Metrics

Article views(1077) PDF downloads(8) Cited by(0)

Access History

Apparatus for producing single strontium atoms in an optical tweezer array

Abstract: We outline an experimental setup for efficiently preparing a tweezer array of 88Sr atoms. Our setup uses permanent magnets to maintain a steady-state two-dimensional magneto-optical trap (MOT) which results in a loading rate of up to 108 s−1 at 5 mK for the three-dimensional blue MOT. This enables us to trap 2 × 10688Sr atoms at 2 μK in a narrow-line red MOT with the 1S0 → 3P1 intercombination transition at 689 nm. With the Sisyphus cooling and pairwise loss processes, single atoms are trapped and imaged in 813 nm optical tweezers, exhibiting a lifetime of 2.5 min. We further investigate the survival fraction of a single atom in the tweezers and characterize the optical tweezer array using a release and recapture technique. Our experimental setup serves as an excellent reference for those engaged in experiments involving optical tweezer arrays, cold atom systems, and similar research.

1.   Introduction
  • The two-electron atoms like ytterbium and strontium in a programmed optical tweezer array[1–3] have shown great promise in quantum metrology, simulation and computing,[4–7] as well as precision measurement in optical lattice clock.[8] Thanks to the rich electronic structures associated with two valence electrons, unprecedented quantum control relevant to Rydberg excitations has been demonstrated in those systems. Recently, Rydberg atoms in reconfigurable optical arrays have been demonstrated high single- and two-qubit operation fidelity,[9] which shows a promising future in quantum simulation and computing based on neutral atoms.[9–12]

    In this work, we illustrate a simple versatile platform for generating cold 88Sr samples in a two-dimensional magneto-optical trap (2D MOT) near the permanent magnets. We demonstrate the loading of 88Sr atoms into the tweezer array after multi-stage cooling. With a steady-state 2D MOT being realized with permanent magnets, we find the loading rate of three-dimensional blue MOT, located in the separate glass cell, up to 108 s−1 at 5 mK. This allows us to trap 2 × 106 atoms at 2 μK in a narrow-line red MOT via operating on the 1S0 → 3P1 intercombination transition at 689 nm. By exploiting the Sisyphus cooling and pairwise loss processes, single atoms are trapped in 813 nm optical tweezers that are generated by the spatial light modulator (SLM). We have implemented the Gerchberg–Saxton algorithm[13] to equalize the depth of the tweezer trap across the array, achieving a uniformity of over 95%. Moreover, we explore the Sisyphus cooling at non-magic wavelength tweezer traps, while characterizing the optical tweezer array through the release and recapture measurement. This versatile strontium tweezer platform provides new possibilities not only for creating Rydberg atom arrays,[4–7] but also for SU(N) fermions.[14–18]

    For elements with high melting temperatures, like strontium and erbium, high-temperature heating is essential. The pre-cooling is usually realized with a Zeeman slower[19,20] or with 2D-MOT with a nozzle.[21] In our experimental setup, the oven is heated at a moderate temperature without the nozzle, and atoms can be easily trapped near the trapping oven. This simple design allows us to minimize the volume of the apparatus.

    The paper is organized as follows. The characterization of the compact vacuum machine, laser systems and optimization for the single-frequency red MOT are detailed in Section 2. Section 3 demonstrates the strontium fluorescence in individual programmed optical tweezers loading from the red narrow MOT, and also shows the approaches to the alignment of the objective to our vacuum machine. In Section 4, we investigate the cooling mechanism in 813 nm optical tweezers with linear polarization under the absence of magnetic field, and study the characteristics of the 813 nm optical tweezers. In Section 5, we give a summary of our optical-tweezer system in the compact vacuum machine.

2.   Experimental setup
  • Figure 1 presents the schematic diagram of the vacuum system and the laser light used to achieve narrow and broad single-frequency MOTs. The entire system, which weighs approximately 50 kg, is mounted on a one-dimensional translation stage to simplify the installation of coils and facilitate vacuum baking. A 30 mm long differential pumping tube with an inner diameter of 2 mm is utilized to maintain balance between the two vacuum chambers. The −x side operates at a high vacuum (UV) level of 10−9 Pa, while the x side functions under ultra-high vacuum (UHV) parameters, reaching 10−10 Pa when the oven (DN16CF) is not heated. A getter ion pump (SAES Getters, NEXTorr D500) is attached to the main chamber to maximize the pumping speed.

    To generate the 2D MOT, the quadrupolar magnetic field is created by four stacks of permanent magnets[22–25] in the y–z plane. Each stack consists of 8 pieces of single N35 neodymium (Nd2Fe14B) magnets (25 mm×10 mm×3 mm) and the magnetization is 6.6(1) × 105 A/m. The inset in Fig. 1 illustrates the 2D MOT configuration with strontium atoms (15 g, Sigma-Aldrich Co., Ltd.). To avoid the hot strontium flux coated on the top view port, which can block the transmission of Zeeman slower beams[25–27] and reduce the atomic flux, we heat up the top sapphire window (located 500 mm away from the oven) to 330 °C. Here, the heating device is an aluminium cylinder with the interlayer being filled with heat band and aluminium silicate thermal insulation. All the view ports can be flexibly connected to a standard 60 mm cage system for mounting optics. A collimated push beam with a 2 mm diameter propagates along the x-axis, producing a steady-state strontium flux. To minimize atom loss during the transport between two chambers, the 2D MOT is situated 2 mm from the entrance of the differential pumping tube which generates the volumetric flow of 3.23×10−2 L/s.

    The UV and UHV chambers are separated by an all-metal gate valve (VAT Co., Ltd.). In the UHV region, the main science chamber is a customized glass cell (Akatsuki Tech Co., Ltd.), with a size of 150 mm×17 mm×27 mm and the wall thickness of 3.5 mm. The glass cell plates are connected by optical bonding (optical contact) method, which can achieve as low as 10−9 Pa. The three retro-reflected MOT beams, with wavelengths of 461 nm and 689 nm, intersect at the center of the glass cell. The two vertical MOT beams intersect at an angle of 120° to provide adequate space for the objective lens, which has a working distance of 15 mm.

    To offset the shallow 60° angle of the MOT beams relative to the gravity axis, the quadrupole coils (not shown) are molded into an oval shape, with the short axis aligned vertically. These coils are formed by winding a hollow square copper wire that is 5×5 mm in size and features a 3 mm diameter hollow space. This setup enables the generation of a 900 G magnetic field in both reverse and forward directions by using an H-bridge switch system.

  • We primarily utilize two optical transitions: a broad-line transition at 461 nm and a narrow-line transition at 689 nm. As depicted in Fig. 2(a), the natural line width of the transition between the 5s21S0 and 5s5p1P1 states is 32 MHz at 461 nm. This allows for the initial cooling stage, known as blue MOT. But there is a 1:50000 weak leakage that the atoms drop down from 5s5p1P1 to the intermediate state 5s4d1D2, which has several hundred μs life time. They subsequently distribute to the two channels of 5s5p3P1,2. For the blue cooling transition, the 3P2 is a dark state with a lifetime on the order of 10 s. In order to have a closed cooling cycle, two repumper beams 707 nm and 679 nm excite the atoms to 5s6s3S1, only one leakage channel makes the atoms populated in 3P1, finally they drop down to the ground state 5s21S0. A high-power 461 nm laser (Second Harmonic Generation, Toptica Co., Ltd.) stabilized by a wavelength meter (WS7-30, HighFinesse) is utilized to cool high-temperature strontium atoms expelled from the oven. As illustrated in Fig. 1, a pair of 2D MOT beams with the waist of 7 mm form a 2D MOT.

    A red-detuned push beam transports atoms into the 3D MOT region in the science glass cell. In the science glass cell, a 461 nm broad-line 3D MOT is formed with the repumping beams at 679 nm and 707 nm (see Fig. 2(a)), which are transmitted through the 689 MOT polarization-maintaining fibers. The natural linewidths of the repumping beams are 1.75 MHz and 8.9 MHz, and their power intensities are 4Is and 7Is respectively. More details on the laser parameters are given in Table 1. In Fig. 2(b), we characterize the loading rate of the steady-state blue 3D MOT (around the temperature of 4.7 mK) with Zeeman and repumper beams, respectively. The atom number can reach a stable level of 4×108 when both Zeeman and repumper beams are present. However, when the Zeeman (rempumper) beam is removed, the atom number decreases to 1/3 (1/8) of its initial value.

  • A narrow-line transition at 689 nm enables cooling of the atoms to a temperature as low as 0.18 μK in the Doppler cooling limit. In order to narrow the laser to the natural linewidth (∼10 kHz), we utilize a fast analog linewidth control (Toptica, FALC pro) to lock the laser to a commercially available ultra-stable cavity with a finesse of 20000. To enhance atom loading into the narrow-line 689 nm MOT from the 3D blue MOT, first, we ramp down the blue MOT intensity to zero to obtain a lower temperature, but do not turn off the repump lasers to pump the residual atoms back to the ground states within 40 ms; second, we broaden the laser linewidth to 5 MHz by modulating the RF driving signal of the double pass acousto-optic modulator (AOM) at a frequency of 40 kHz,[28] which generates 125 distinct “comb” peaks spanning the entire range of modulation.

    The detailed experimental sequence for realizing a narrow MOT is shown in Fig. 2(c). After the blue MOT is established, we switch off the 2D MOT lasers, the push beam, 2D cooling beam, and Zeeman slower laser simultaneously. Then, within 10 ms, the intensity of the 3D blue MOT cooling beam is adiabatically ramped down to zero. After additional 40 ms, the 707 nm and 679 nm repumping lasers are immediately turned off.

    The transitions of 1S1→ 1P1 and 3P1 require significantly different magnetic field gradients. To this end, we employ a commercially available high-bandwidth PID (proportion integration differentiation) device (Newport LB2005) that takes only 100 μs to rapidly decrease the magnetic field from 50 G/cm to 6 G/cm. The 689 nm cooling light has been continuously enabled, accompanied by a frequency modulation within a range of 5 MHz.

    With 5 ms loading into the red MOT, the magnetic field gradient begins to ramp up to 9.3 G/cm for compressing the atom cloud. The entire process takes about 90 ms, resulting in the atom temperature of 150 μK. To achieve lower temperature, the modulation frequency gradually decreases to zero following an exponential damping. The MOT beam intensity also ramps down with an exponential function. Achieving a narrow red MOT with 200 kHz red detuning from the resonance of 1S0 and 3P1, we obtain 2 × 106 cold strontium atoms at the temperature of 2 μK. This greatly assists us in loading atoms into optical traps, with the specific details to be discussed in the next section.

3.   Optical tweezers for trapping atoms
  • The creation of tweezer arrays using the spatial light modulator (SLM) often faces a trade-off between the quality of reconstruction and the time required for calculations. We have successfully loaded cold strontium atoms into various optical tweezer patterns generated by an SLM integrated with a generative neural network.[29] This approach shortens the process time to control the SLM with minimal time delay, eliminating the need for repeated re-optimization of the hologram for the SLM.

    As shown in Fig. 3(a), the horizontal MOT beam propagates along the z-axis, while also provides cooling during the fluorescence imaging process. The probe beams, intersecting at an angle of approximately 10° with the cooling (MOT) beam (3) in the x–z plane, consists of a pair of counter-propagating beams with a frequency offset of approximately 0.5 MHz to avoid the optical interference. The intensity of the probe beam is stabilized during fluorescence imaging. In our experimental setup, we choose to establish a zero external magnetic field, as this has the advantages of not only reducing the complexity of calculating the energy shift, but also having the capacity to maximize the effectiveness of fluorescence imaging.

    The 813 nm optical tweezer beam propagates along the y-axis, and its polarization sets the quantum axis (when a linear polarized propagating optical modes with a cross section comparable to the wavelength). Assuming the tweezer beam propagates along the y axis, the fictitious magnetic fields induced by AC stark shift can be written as[30]

    Here αv is the vector polarizability, ω0 is the beam waist radius, μB is the is Bohr magneton, uy is the unit vector along y, ε is the complex unit tweeezer polarization vector, εmax0 is the value ε0 at the origin. The 813 nm optical tweezer laser with polarization aligned in the imaging beam direction serves as the quantization axis for internal state transitions. The two counter-propagating 461 nm probe lasers propagate horizontally in the radial plane, where the atoms are trapped by a high trap frequency.

    The AOD (not used in this work) and SLM provide dynamic and static optical tweezer arrays, respectively. At the top, a CMOS camera directly monitors the optical tweezers for real-time calculation of the SLM phase map.

    In our experiment, we create tightly focused optical tweezer traps with the beam waist in the 1 μm range for single atom trapping. As shown in Fig. 3(b), we have chosen a pair of commercial microscope objectives (Mitutoyo, G Plan Apo 50×) with a numerical aperture (NA) of 0.5. Both objective lenses are installed on a five-axis electric translation stage (Newport, 8082-M), which has the minimum precision of 30 nm. We delicately manipulate the tilt angle and precise placement of the objective lens so that the fluorescence pathway is parallel to the tweezer beam. To estimate the focal position of the tweezer trap, we use a probe beam from bottom up to excite the fluorescence while activating 2D MOT and push beam.

4.   Trapping atoms in a tweezer array
  • The 813 nm tweezer trap, with a waist of ∼700 nm, exhibits multiple intensity maxima with the intensity distribution being a sinc function in the focal plane. To minimize atom loading into subsidiary intensity maxima,[31,32] we first start the optical tweezer with a shallow trap depth of 24 μK, and subsequently ramp up to 543 μK. When loading atoms into the optical tweezers, a single atom is achieved through a light-assisted collision (LAC), which induces pairwise atom loss using a red-detuned 689 nm light.[4,33,34] While the pairwise loss is sensitive to the trap depth,[35] we speed up this process to 30 ms by exciting atoms to the 1P1 state using a red detuned 461 nm light.

    To have a single-site and single-atom-resolved fluorescence imaging, we collect fluorescence photons with a high-sensitivity qCMOS (Hamamatsu ORCA-Quest C15550-20UP) camera. The frequencies of these two probe laser beams are adjusted to be red detuning 24 MHz from the AC stark shifted resonance in the optical tweezers, and the power intensity (0.001Is) is balanced to each other, ensuring an appropriate scattering rate no more than the cooling rate. During the imaging, we apply Sisyphus cooling to mitigate the heating process. As shown in Fig. 4(a), the excited state 3P1 and 1P1 potential is deeper than the ground state 1S0 one due to the AC stark shift. Atoms initially at the trap of ground state, when excited to the excited state, experience a more steep climb than their original state in the ground state. Following spontaneous emission, the disparity between the energy levels leads to a reduction in the atom’s average energy.[36,37]

    Figure 4(b) shows the lifetime achieved using the optimized Sisyphus cooling and probe beams at the absence of the cooling beam. Without the cooling beam, the lifetime is only around 1 min. However, with the application of the cooling beam, it effortlessly extends to 2.5 min. With a constant trap depth of kB × 543 μK, the high survival fraction is achieved in the cooling beams with red detuning from −1.4 MHz to −1.8 MHz, as illustrated in Fig. 4(c). For more precise measurement, we use release and recapture method to determine a narrower and effective cooling frequency range. In Fig. 4(d), it shows the relation between the scattering rate and the survival fraction, below the 35 kHz, the survival fraction can be reaching to the asymptotic line.

  • To estimate the temperature of trapped atoms in the tweezer trap, we use the release and recapture method. In Fig. 5(a), we vary the release time and measure the survival fraction, from which the temperature is around 27 μK in comparison to the Monte Carlo result.

    The trap depth of each tweezer affects the Sisyphus cooling effect during the imaging process. To keep the constant trap depth of the 3×6 tweezer array, we first detect the tweezers pattern using CMOS camera, and subsequently feedback the tweezer intensity based on the Gerchberg–Saxton algorithm.[38] The typical trap depth is precisely determined by the atom loss spectroscopy with the intercombination transition on 1S0 → 3P1 at 689 nm. Finally, the trap depth of 18 single atoms has a standard deviation of around 1.5%, as shown in Fig. 5(b). Alternatively, the radial oscillation frequency can be monitored as shown in the inset via release and recapture method. (In our experimental sequence, the 813 nm tweezer beam switch twice, the initial release time Δt1, is to enhance the atoms oscillation amplitude, the release time Δt2, optimized to have a recapture probability). The atoms have a harmonic oscillation in the trap during the holding, the probability of the recapturing atoms varies due to the oscillation at different positions in the trap. Notably, from the insightful inset presented in Fig. 5(b), the radial trap frequencies are 2π × 103(2) kHz, while the calculated trap depth and axial trap frequency are 543 μK and 2π × 26.9(3) kHz, respectively.

    Figure 5(c) shows the histogram of background and single atoms fluorescence of the 18 tweezers array. Two peaks are clearly observed, separated by the threshold line of 200. Also the equality of the integrated area suggests that the loading efficiency of single atoms is 50%. In our experiment, a 100 ms imaging time is employed to obtain a distinct signal that surpasses the background noise. Finally, we show the tweezer pattern of the 3×6 array with a maximal distance of 9 μm in Fig. 5(d) by averaging the fluorescence of 50 images. Figure 5(e) illustrates the experimental timing sequence, which is utilized for fluorescence detection and the measurement of trapping frequency. In the case of the histogram and tweezer array pattern, the sequence is reiterated after first imaging. Conversely, for ascertaining the survival fraction, the atomic array is imaged in a repeated dual-imaging process.

5.   Summary and conclusion
  • We present a compact experimental apparatus designed for a strontium Rydberg array. By applying Zeeman slower beam, we efficiently decelerate the atomic beam ejected from the atomic oven, and produce a 2D MOT. Consequently, we transport atoms into the 3D blue MOT, and ultimately achieve a red MOT with a temperature of 2 μK and a population of 2 × 106 atoms, which facilitates the loading of an optical tweezer array formed. We characterize 813 nm optical tweezer traps with imaging and Sisyphus cooling beams, and quantitatively calibrate experimental parameters by means of measuring and simulating trap frequencies and atomic temperatures through release and recapture method and Monte Carlo simulation. Additionally, we have found that employing a three-dimensional red MOT as the Sisyphus cooling beams is enough and could reduce the complexity of the experimental setup, facilitating daily maintenance. Our newly developed tweezer array setup provides a versatile platform for quantum information processing and quantum simulation with alkaline-earth-like atoms.[39]

Figure (5)  Table (1) Reference (39)

Catalog

    /

    DownLoad:  Full-Size Img  PowerPoint
    Return
    Return