2025 Volume 34 Issue 1
Article Contents

Ming Ni, Rong-Long Ma, Zhen-Zhen Kong, Ning Chu, Wei-Zhu Liao, Sheng-Kai Zhu, Chu Wang, Gang Luo, Di Liu, Gang Cao, Gui-Lei Wang, Hai-Ou Li, Guo-Ping Guo. Correcting on-chip distortion of control pulses with silicon spin qubits[J]. Chinese Physics B, 2025, 34(1): 010308. doi: 10.1088/1674-1056/ad8db1
Citation: Ming Ni, Rong-Long Ma, Zhen-Zhen Kong, Ning Chu, Wei-Zhu Liao, Sheng-Kai Zhu, Chu Wang, Gang Luo, Di Liu, Gang Cao, Gui-Lei Wang, Hai-Ou Li, Guo-Ping Guo. Correcting on-chip distortion of control pulses with silicon spin qubits[J]. Chinese Physics B, 2025, 34(1): 010308. doi: 10.1088/1674-1056/ad8db1

Correcting on-chip distortion of control pulses with silicon spin qubits

  • Received Date: 02/09/2024
    Accepted Date: 22/10/2024
    Available Online: 01/01/2025
通讯作者: 陈斌, bchen63@163.com
  • 1. 

    沈阳化工大学材料科学与工程学院 沈阳 110142

  1. 本站搜索
  2. 百度学术搜索
  3. 万方数据库搜索
  4. CNKI搜索

Figures(4)

Article Metrics

Article views(866) PDF downloads(6) Cited by(0)

Access History

Correcting on-chip distortion of control pulses with silicon spin qubits

Abstract: In semiconductor quantum dot systems, pulse distortion is a significant source of coherent errors, which impedes qubit characterization and control. Here, we demonstrate two calibration methods using a two-qubit system as the detector to correct distortion and calibrate the transfer function of the control line. Both methods are straightforward to implement, robust against noise, and applicable to a wide range of qubit types. The two methods differ in correction accuracy and complexity. The first, coarse predistortion (CPD) method, partially mitigates distortion. The second, all predistortion (APD) method, measures the transfer function and significantly enhances exchange oscillation uniformity. Both methods use exchange oscillation homogeneity as the metric and are suitable for any qubit driven by a diabatic pulse. We believe these methods will enhance qubit characterization accuracy and operation quality in future applications.

1.   Introduction
  • Universal quantum computation requires both single-qubit and two-qubit gates with long coherence times and high gate fidelities.[1–4] For qubits defined in semiconductor quantum dots, accurately delivering the control waveform to the device is essential for successful gate operations.[5–7] Optimizing the control waveform is a widely used method to enhance gate fidelity during qubit gate implementations.[8–12] However, waveform distortion is inevitable in the measurement system, which hinders the achievement of high-fidelity qubit gates and sequences.[8,13–15] Additionally, an accurate measurement pulse is crucial for system characterization, such as noise measurements[16,17] and energy-level structure analysis.[18,19]

    Pulse distortion in the measurement system can arise from factors like limited arbitrary waveform generator (AWG) bandwidth, filtering effects, skin effect, and impedance mismatch. In general, pulse distortion can be described by a transfer function h(t), which captures the influence of all distortion sources along the control line, from room temperature electronics to the qubit on the chip. Once the transfer function is calibrated, predistortion corrections can be applied to the control pulse to compensate for the distortion. While pulse distortion can be easily measured at room temperature using a vector network analyzer or oscilloscope, at cryogenic temperatures, qubits are often used as sensors to detect the response of control pulses.

    For superconducting qubits, various techniques have been developed to calibrate waveform distortion.[20–26] Similarly, for spin qubits in semiconductor quantum dots, previous efforts have aimed to eliminate pulse distortion in the control line. In singlet-triplet (ST) qubits, used as detectors, gate fidelities are optimized using the Levenberg–Marquardt algorithm (LMA) to mitigate both decoherent noise and pulse distortion.[27–29] However, in these works, distortion is calibrated alongside noise, making it difficult to separately address pulse distortion. Another approach uses phase accumulation during exchange oscillation as an indicator to estimate the system transfer function, but this method is sensitive to noise and effective only over short time intervals.[30]

    In this article, we propose two methods to calibrate pulse distortion in a two-qubit system using exchange oscillation as the detector. These methods provide the system’s transfer function and calibrate distortion over both short (∼ns) and long (∼μs) time intervals, making them applicable in a range of scenarios.[8,13–19] The first method, coarse predistortion (CPD), primarily corrects distortion caused by the bias-tee by using the frequency spectrum width of the oscillation as a calibration standard. The second method, all predistortion (APD), offers higher correction accuracy and but more complexity by using oscillation pole positions as the standards to calibrate the system’s transfer function. With the corrected waveform, we observed a significant improvement in exchange oscillation uniformity, demonstrating the effectiveness of these calibration procedures.

2.   Results
  • We conduct our experiment on a gate-defined two-qubit device fabricated on a 70-nm isotopically purified 28Si epilayer.[31–33] As depicted in Fig. 1(a), the left qubit QL and right qubit QR are positioned beneath the plunger gates PL and PR, respectively. Electrons tunnel between the quantum dots and the electron reservoir beneath gate RG, with the tunneling rate controlled by the voltage on gate BL. DC voltages applied to the plunger gates create potential wells that confine the electrons. Our experiments are performed in the (3,1) charge configuration under an external magnetic field B0 = 605 mT. Both qubits are read out and initialized as described in Ref. [34]. Qubit QL is directly read out and initialized via spin-selective tunneling with the left reservoir. However, QR has a slower tunneling rate and requires spin shuttling to the left quantum dot for readout and initialization. The detuning ε between the two qubits is controlled by adjusting the relative voltages on PL and PR, and the tunnel coupling tc is tuned by the gate voltage on BR.

    Figure 1(a) also illustrates the measurement setup. Our system requires control signals ranging from kHz for single-shot readout and initialization to GHz for single-qubit and two-qubit gate operations. Two arbitrary waveform generators (AWGs) are used: AWG1 generates kHz pulses, while AWG2 generates GHz pulses. Additionally, two vector microwave sources (MW1 and MW2) drive qubits QL and QR, respectively. To simultaneously deliver both pulses and microwaves to the device, two bias tees are connected to the plunger gates at cryogenic temperatures. The kHz pulse is combined with the DC voltage at room temperature and delivered via the DC port of the bias tee, while the GHz pulse is combined with the microwaves and delivered via the RF port. Among the input signals, distortion in the GHz pulses, introduced through the RF port, impacts the qubit control. In this work, we focus on correcting GHz pulse distortions to improve the performance of two-qubit gate operations.

  • For the two qubits QL and QR formed in two adjacent quantum dots, their Zeeman splitting energies Ez differ due to the Stark shift.[5–7,35] Meanwhile, the exchange coupling J is always present and can be tuned by the detuning ε. Here, we focus on the basis of antiparallel states |↑ ↓〉 and |↓ ↑〉, with the Hamiltonian given by

    where ΔEz is the Zeeman splitting energy difference for the two qubits. As mentioned earlier, the detuning ε between the two qubits can be adjusted by the relative gate voltages VPL and VPR. When diabatic pulses are applied to the plunger gates, the two-qubit state remains static while the eigenstates evolve due to the modified ε, as illustrated in Fig. 1(b).[37] The exchange coupling oscillation will occur between the two qubits, with a frequency equal to the energy difference between the two antiparallel eigenstates, given by fex=ΔEz2+J2.[34] In our device, since J ∝ exp (ε)[6] and ΔEz ∝ ε we should observe a homogeneous exchange oscillation with frequency fex as long as the top edge of the diabatic pulse is flat. If the two qubits are initialized to the state |↑ ↓〉, figure 1(c) illustrates the oscillation of the probability of the state |↑ ↓〉 driven by both undistorted and distorted pulses. A slight distortion at the top edge will alter the pulse amplitude as well as ε at the operational point, leading to a change in fex and resulting in apparent inhomogeneous oscillation. In our experiment, when the top edge of the fast pulse is flat, we observe a gradual slowdown in the exchange oscillation frequency, as shown in the un-predistorted (UPD) situation in Fig. 4(a). This indicates that the control pulse is distorted and that the top edge decays over time. We attribute this distortion to the RC filter circuit within the bias tee, which causes the top edge of the square pulse to decay.

  • The pulse affected by the RC filter circuit is illustrated in Fig. 2(a). For a diabatic square input pulse Uin (t), the output pulse after passing through the circuit is denoted as Uout (t)), which serves as the control signal for the two qubits. In the absence of distortion from the circuit, Uout (t) would initially rise and then maintain a stable amplitude Ain, matching the amplitude of Uin (t). However, when distorted by the RC filter circuit, Uout (t) will behave differently. After the rising edge, the output pulse Uout (t) will experience exponential decay at the top edge due to the circuit distortion, following the form Uout (t) = Aine−t/τ, where t is the duration time of the top edge and τ is the time constant of the RC filter circuit, which depends on the values of the capacitor and resistor in the RC circuit. Subsequently, after the falling edge, Uout (t) will drop sharply and then rise exponentially to zero. To fully compensate the Uout (t) into a diabatic square pulse, the input pulse should has the form Uin (t) = Ain(1 + kt). In our experiment, to predistort Uin (t), we employ a pulse with a linearly ramped top edge given by UPD,in (t) = Ain(1 + kt) where k is a constant that determines the slope of the ramp. As illustrated in Fig. 2(a), this linearly ramped top edge can effectively compensate for the decay induced by the RC filter circuit. To achieve complete correction of the bottom edge, the predistorted pulse must maintain a nonzero voltage level of Ainkt after the falling edge. Considering the inevitable return to a zero voltage level following the falling edge, we linearly decrease the voltage to this zero-voltage level and neglect the effect of any remaining distortion.

    To detect the ramp rate k, we measure the exchange oscillation as k increases. The time domain behavior of the oscillation with increasing k is shown in Fig. 2(b). The spin-up probability P| ↑ ↓〉 exhibits inhomogeneous oscillations over time. To characterize this inhomogeneity, we transform the data from Fig. 2(b) into the frequency domain, allowing us to assess the homogeneity of the exchange oscillation. The frequency spectroscopy is presented in Fig. 2(c). When k is approximately 0.06 μs−1 to 0.08 μs−1, the spread of the frequency peak is at its narrowest, indicating that the oscillation homogeneity is optimized. Consequently, we select k = 0.07 μs−1 for subsequent experiments, which corresponds to a time constant of τ ≈ 1/k ≈ 14 μs for the RC circuit. Although the linearly ramped top edge mitigates some distortion, the exchange oscillation remains disturbed when the oscillation frequency exceeds 20 MHz, as demonstrated in the CPD situation shown in Figs. 4(a) and 4(b). This observation suggests that residual distortion still impacts the oscillation, indicating the necessity for a more precise calibration method.

  • In the regime of J ≫ Δ Ez, the exchange oscillation frequency fex ≈ J (ε) due to the exponential dependence between J and ε. As Ain increases, ε at the operation point increases as well, and the exchange oscillation frequency increases exponentially.[6] Therefore, the higher the Ain is, the more sensitive the fex is to pulse distortion. A natural thought is calibrating the control pulse according to the accumulated exchange oscillation phase. However, the phase is susceptible to decoherence and the spin preparation and measurement (SPAM) error. In contrast, the extremum points where the phases are equal to n⋅π (n = 1,2,3,…) have decoherence and SPAM error insensitive performance and are suitable as the distortion metric. In our experiment, we adjust Ain and choose a fixed pulse duration λ to obtain the predistorted pulse. When Uin (t) is not disturbed, 2π fex (Ain) λ = π (or 2π), and the spin-up probability P| ↑ ↓〉 will reach extremum points at time t = n⋅λ (n = 1, 2, 3, …). With the distortion, while making P| ↑ ↓〉 still reach extremum points at the moment t, we need to adjust Ain of Uin (t) during each time segment λ. After modifying the Ain of Uin (t), we can obtain the Uin (t), which corresponds to a square wave output pulse Uout (t). Although the pulse distortion will also influence the falling edge, due to the nonlinear dependence between the pulse amplitude and the exchange oscillation frequency/axis angle and the compensated pulse in Fig. 2(b), the influence of the pulse distortion during the falling edge can be neglected, we can only focus on calibrating the distortion in the rising edge (see supplementary material 4 for more detail).

    Before correcting the control pulse, we calibrate the relationship between fex and Ain (see supplementary material 1 for more detail), with which we can determine the un-distorted Ain corresponding to fex (Ain) = π /λ (or fex (Ain) = 2π/λ). The following steps summarize the experimental procedures.

    (i) According to the dependence between fex and Ain, we calculate the Ain,1 that makes the accumulated phase ϕλ1 equal to π (2π) at time λ1. Here, λ1 is the fixed temporal resolution of the calibration procedure, and we assume that the output voltage level during λ1 is constant. For example, in Figs. 3(a) and 3(b), we chose the Ain,1 corresponding to fex = 10 MHz when ensuring λ1 = 0.1 μs to guarantee ϕλ1 = 2π.

    (ii) Keep the input square pulse duration as λ1 and set the pulse amplitude as c11Ain,1, where c11 is the predistortion coefficient. Sweep c11 around 1 and find the predistortion coefficient c11, which corresponds to the extremum value of P|↑ ↓〉. As illustrated in Figs. 3(a) and 3(b), c11 is swept in the interval [0.95, 1.05] and chosen as the value corresponding to the maximum P| ↑ ↓ 〉.

    (iii) Keep the input square pulse Uin (t) duration as 2λ1 and set the pulse amplitude in the time interval [0, λ1] as c11Ain,1. In the time interval [λ1, 2λ1], we set the pulse amplitude as c12Ain,1 and sweep c12 around 1 to find c12 that corresponds to the extremum value of P|↑ ↓〉.

    (iv) Repeat Step (iii) and determine c1 = [c11, c12, c13,…, c1n]. The orange pulse segments in Figs. 3(a) and 3(b) correspond to the calibrated c1 = [c11, c12, c13,…,c110].

    (v) To increase the calibration temporal resolution, decrease the calibration duration step λ2, calculate Ain,2 and repeat Steps (i)–(iv) to determine the value of c2. Before this step, set Uin (t) as c1u (t), and u (t) is the square pulse with amplitude Ain,1. In Figs. 3(c) and 3(d), we chose λ2 = 0.05 μs, fex = 20 MHz, and ϕλ2 = 2π. The calibration of c2 is based on the calibrated pulse in Fig. 3(b).

    (vi) Decrease the calibration duration step λm and calibrate cm = [cm1, cm2, cm3,…, cmn] until the temporal resolution is sufficient.

    (vii) Calculate the predistorted input pulse as Uin (t) = c1c2 … cmu (t). Finally, we obtain Uin (t), which ensures that the pulse delivered into device Uout (t) is an exact square pulse.

    The APD input pulse Uin,APD (t) in our experiment is shown in Fig. 3(e). As the contrasts, we also give the CPD pulse Uin,CPD (t) with a line ramped top edge and the initial square pulse Uin,UPD (t). Two rounds of iterations with λ1 = 40 ns and λ2 = 20 ns are implemented successively to obtain Uin,APD (t). The phase step is π, and the sweeping interval of c is [0.85, 1.15]. During the duration [0 ns, 80 ns], the pulse amplitude of Uin,APD (t) is lower than that of Uin,CPD (t) which should correspond to the lower oscillation frequency. In Fig. 4(a), in comparison to the exchange oscillation driven by Uin,CPD (t), we observe that the exchange oscillation driven by Uin,APD (t) is indeed slower and more homogeneous. Similarly, the pulse amplitude of Uin,APD (t) within time [80 ns, 220 ns] is higher, which also improves the oscillation homogeneity compared to Uin,CPD (t). The significant conformity confirms the validity of this procedure. Although the trend is corrected, Uin,APD (t) in Fig. 4(c) is still disturbed by some glitches due to the exchange oscillation instability. To smooth these glitches, we fit Uin,APD (t) with a polynomial curve. We speculate that the glitch problem can be relieved by averaging more time during the calibration or with a higher quality exchange oscillation.

    Although the validity is confirmed, this calibration procedure still has some limitations, predominantly in the temporal resolution, longest correction time, and accuracy, and is mainly influenced by the exchange oscillation characteristics. Specifically, the temporal resolution λm depends on the fastest exchange oscillation frequency, and the coherence time of the exchange oscillation determines the longest correction time n⋅λm our procedure can calibrate. The accuracy of this procedure is dominated by the phase step we choose; in other words, the larger the phase step we choose, the more susceptible the extremum point is. However, for the same λm, a larger phase step means that a higher fex is needed, which is often accompanied by a faster decoherence speed and results in a shorter correction time. Thus, these parameters should be chosen carefully.

    Remarkably, two situations could lead to the failure of the APD procedure. The first is the occurrence of multiple peaks within the scanning interval of c. As illustrated in Fig. 3(f), when modifying cmn, we observed a gradual increase in the oscillation frequency. For different pulse durations λ shown in Fig. 3(f), the latest extremum points are detected when Ain0 shifts by 0.48Ain0, 0.18Ain0, and 0.14Ain0, respectively. Here, Ain0 denotes the ideal pulse amplitude corresponding to the extremum point. A higher temporal resolution, along with a smaller λ, is more likely to lead to multiple peaks. When the sweep interval is excessively large, multiple peaks may emerge, resulting in a misleading determination of cmn. The second situation that can lead to the failure of the APD procedure occurs when the distortion is so severe that we detect the wrong probability peak. Paradoxically, while a narrow sweeping interval for cmn is recommended to avoid the multiple peak phenomenon, it may cause us to miss the extremum point when the distortion is significant. To address this, we propose starting with a longer temporal resolution and a larger λ, which typically corresponds to a smaller average distortion and reduced disturbance from the multiple peak phenomenon. This approach allows us to select a narrower sweeping interval, which we can then refine by increasing the resolution during multiple iterations. Alternatively, employing the CPD procedure before the APD procedure can also be beneficial. In general, careful selection of the temporal resolution, λm,n, and c is crucial to ensure the validity of the calibration procedure, based on the characteristics of the exchange oscillation.

    With Uin,APD (t), we can easily calculate the transfer function h(t) and the inverse transfer function h−1(t)=Uin,APD′(t), allowing us to obtain the predistorted pulse for any arbitrary output pulse Uin,APD (t) = h−1 (t)⋅ Uout (t) (see supplementary material 2 for more details). In Fig. 4(a), we demonstrate the time dependence of the exchange oscillation using Uin,UPD (t), Uin,CPD (t), and Uin,APD (t) as a function of Ain. To illustrate the homogeneity of the oscillation, we transform the exchange oscillation from the time domain to the frequency domain, as shown in Fig. 4(b). When the UPD pulse Uin,UPD (t) is applied to the qubits, as Ain increases, the frequency spectrum of the exchange oscillation becomes unclear. As previously mentioned, fex gradually slows down over time, primarily affected by the RC filter circuit. Consequently, we correct the distortion with a linear ramp top edge. In Fig. 4(b), under the CPD situation, the frequency spectroscopy improves when fex is below 20 MHz, but it remains unclear at higher frequencies. This indicates that while the distortion is partially mitigated, the influence of the residual distortion is still apparent. With the APD procedure, the frequency spectroscopy remains clear even when fex exceeds 20 MHz, leading to a significant improvement in homogeneity. The residual width of the frequency peak is attributed to oscillation decoherence and low temporal resolution, which is approximately 50 MHz in this case.

3.   Discussion
  • The calibrated pulse is essential for characterizing coherence time and identifying error sources. Compared to the CPD method, the APD procedure focuses on calibrating distortions in the first few oscillations, which is critical for enhancing gate fidelity. The APD method’s temporal resolution is determined by the highest oscillation frequency (in the GHz range), which easily meets the sub-microsecond pulse requirements for gate operations. Although higher oscillation frequencies provide better temporal resolution, optimal gate fidelity is achieved at slower oscillation frequencies. By calibrating distortion during the initial oscillations, gate fidelity can be improved even at intermediate operation points or during π/2 rotations. When choosing between the CPD and APD methods, experimental requirements play a key role. The CPD method offers faster calibration but at the cost of precision, while the APD method, through iterative processes, delivers higher accuracy. For oscillation frequencies below 20 MHz, the calibration accuracy of both methods is comparable, and deviations in peak frequency width may result from unaveraged disturbances. Therefore, CPD is suitable for experiments prioritizing speed, while APD is better suited for those requiring higher precision.

    In our experiment, both predistortion methods exhibit noise immunity and can effectively calibrate over long time intervals. For exchange oscillation, the primary source of error is quasi-static charge noise, which leads to decoherence. However, decoherence does not compromise the calibration accuracy of either predistortion method, allowing us to calibrate pulse distortion for longer pulses. In the CPD method, while decoherence broadens the frequency spectrum of the oscillation, this band spread does not invalidate the CPD method since the predistortion coefficient k corresponds to the relatively narrowest band. For the APD method, we determine pulse distortion using extremum points; both the pulse amplitude and duration associated with these extremum points exhibit noise immunity and remain unaffected by oscillation decoherence. Benefiting from these factors, we can utilize these methods to enhance control pulses not only for gate operations[8,13–15] but also for system characterization.[16–19]

    On a larger scale, both the CPD and APD methods can be applied to calibrate pulse distortion for various types of qubit encodings and substrate materials, with the only requirement being oscillation driven by a diabatic pulse. For instance, leveraging the exchange interaction between qubits, the exchange oscillation observed through Elzerman readout or Pauli spin-blockade (PSB) readout serves as an excellent mechanism for calibrating pulse distortion in single-spin qubits, singlet-triplet (ST) qubits, exchange-only qubits, and donor-based qubits encoding electron spins. The diabatic pulse can be applied to both ε and tc. Additionally, the oscillation driven by the diabatic pulse on ε can stem from spin–orbit coupling or spin–valley coupling. The calibrated pulse can further enhance the operation of hybrid spin–valley qubits. Beyond qubits based on silicon MOS, these two methods can also be effective for qubit encodings on different substrate materials, such as SiGe/Si, GeSi/Ge, nanowires, and FinFET.

4.   Summary
  • In summary, we demonstrated two distinct methods for calibrating distortion in our system by using the two-qubit exchange oscillation in a silicon metal–oxide–semiconductor (MOS) quantum dot as the detector. The CPD procedure, which features a linear ramp top edge, rapidly calibrates distortion originating from the bias tee. Meanwhile, the APD procedure, which uses the extremum value of P|↑ ↓〉 as a metric, characterizes the transfer function of the measurement system. We observed a significant improvement in the homogeneity of exchange oscillation with the transfer function across all frequency ranges. These methods are straightforward and suitable for any qubit system exhibiting oscillation driven by a diabatic square pulse. We believe this correction procedure has the potential to enhance gate fidelity and system characterization in future experiments.