HTML
-
Dielectric barrier discharge (DBD) is widely used in many fields such as material processing, resource environment, energy and chemical industry, and biomedicine.[1–6] DBD at atmospheric pressure easily leads to the formation of filamentary discharges.[7] The energy in filamentary discharge channels is more concentrated,[8] which can result in non-homogeneous treatment effects and potential damage to the material.[9] Therefore, achieving a moderate discharge intensity without obvious discharge filaments is essential.[10]
It is difficult to realize uniform discharge under atmospheric pressure in air, and dynamic discharge can improve the uniformity of discharge.[11,12] In recent years, some results have been achieved in the research on dynamic discharge plasma.[13–16] The current methods for generating dynamic discharges include rotating sliding arcs, rotating dielectric layers, and rotating ground electrodes.[17–20] Li et al.[21] studied a large-area atmospheric pressure plasma jet using air as the working gas, and a dynamic discharge was obtained by rotating the plasma jet to form a sliding arc, and the sliding arc formed was able to enhance the uniformity of the discharge and reduce the probability of non-uniform discharge phenomena under certain airflow condition.
Jiang et al.[22] used a rotating dielectric barrier layer to obtain dynamic discharge, and the rotating dielectric barrier layer can effectively increase the discharge power and the number of current pulses. Increasing the average gray value and decreasing the gray standard deviation further demonstrated its role in improving the macroscopic uniformity of the discharge. Yu et al.[23] designed a rotating ground electrode dielectric barrier discharge actuator to obtain dynamic discharge and generate ozone. With the electrode rotating under the influence of a high-frequency high-voltage AC power supply, ozone generation efficiency improved and discharge uniformity was enhanced.
Current research primarily focuses on achieving dynamic discharge through the rotation of the ground electrode.[24–28] However, the material to be modified is typically positioned on the ground electrode, which means that rotating the grounding electrode affects the uniform discharge, and the uniform discharge affects the results of the material treatment. In this paper, we mainly design a set of dielectric barrier discharge actuator for rotating high-voltage electrode, which can form a long-time uniform discharge, uniform discharge can optimize the discharge performance. The study of the characteristics of the discharge channel distribution under different rotational speeds of the actuator is analyzed experimentally. At the same time, the voltage amplitude of the actuator is varied to analyze the physical process and discharge mechanism of the rotating process.
-
The discharge experiment was conducted in atmospheric pressure air, with the experimental setup and measurement system constructed on an optical platform. Figure 1 shows the structure of the rotating dielectric barrier discharge actuator used in the experiment, positioning the high-voltage electrode and the ground electrode on both sides of the dielectric plate, respectively. The high-voltage electrode is made of copper, has a circular shape, and is fixed to the high-voltage electrode shaft by a screw, and the circular electrode has a diameter of 80 mm. The ground electrode is made of ITO glass and has a square shape, the side length of the square being 100 mm. The dielectric on both the high-voltage and ground electrode sides is made of high-purity silica glass. The high-voltage electrode is rotated by a servo motor, and an insulated drive shaft isolates the high-voltage electrode from the motor, preventing damage to the motor from the high-voltage power supply while ensuring the safety of the experiment.
The experimental system, as shown in Fig. 2, consists of a plasma generation part, a control part, and a measurement part. The plasma generation part includes power supply and rotating DBD actuator, the control part includes servo driver and upper computer, and the measurement part includes oscilloscope, high voltage probe, current coil, and high precision camera. In this paper, we study the discharge characteristics under high-frequency high-voltage AC power supply. The power supply used for the experiment is the low-temperature plasma experimental power supply CTP-2000K, with an output voltage amplitude range of 0 kV–30 kV and an adjustable frequency range of 5 kHz–20 kHz. In the experiment, the power supply frequency ranges from 7 kHz to 10 kHz, and the voltage amplitude varies from 8 kV to 15 kV. The voltage measurement adopts the high-voltage probe Tektronix P6015, and the current measurement adopts Pearson current monitor 4100, and Tektronix DPO 2024 was used for voltage and current waveform recording; the discharge images were captured with a digital camera, Canon EOS 5D Mark III, with a Tamron 100 mm–400 mm lens, and the camera was operated at a maximum shooting speed of 6 fps, a minimum exposure time of 125 μs, and the ISO value of 102400, and the maximum aperture value is f/4.5.
In the experiment, we mainly choose the high-speed continuous shooting mode, the maximum shooting frame rate of this mode is 6 fps, and the exposures time is 25 ms and 40 discharged images are captured consecutively. In this paper, SV-DA200 AC servo drive is used to control the electrode rotation online, and the electrode rotation direction is counterclockwise.
To investigate the elongation of the discharge channel induced by the rotation of the high-voltage electrode, a more in-depth study was carried out to record the development of the discharge using an SSZN SH3-103 high-speed camera. The camera has a maximum frame rate of 2.19 × 105 fps and a full resolution of 1280×1024, equipped with a Tamron SP AF 70 mm–200 mm F/2.8 lens.
-
The texture characteristics and morphological parameters of micro-discharge channels are critical indicators of DBD plasma generation.[29] In this paper, the number of micro-discharge channels and topographical parameters are calculated by digital imaging techniques. To study the discharge region, it is necessary to segment the images of the discharge region and non-discharge region, and this paper adopts the threshold segmentation calculation method to obtain the image region with only discharge channels, and then analyze the texture characteristics of the micro-discharge channels.
As an example, the process of texture feature analysis for the discharge images when the electrode is stationary (n = 0 rpm) is shown in Fig. 3. First, the original image (a) is locally extracted to get the true-color image (b). Then, the true-color image is converted to a grayscale image (c) using the Eq. (1). The grayscale image is processed by threshold segmentation to get the binary image (d). Next, the contour of the discharge region is extracted from the binary image (e), and finally the contour of the discharge region is elliptically fitted to obtain Fig. 3(f).
After thresholding the images, the undischarged points in the images caused by factors such as experimental bias and interference from external light sources are eliminated. An image opening operation is then performed on the processed binary images, resulting in Fig. 3(d). With these images, the number of micro-discharge channels and the parameters of the discharge channels can be counted and calculated.
-
The frequency of the rotating high-voltage electrode is f = 9 kHz. Figure 4 shows the variation in the number of micro-discharge channels at different electrode rotational speeds for voltage amplitudes of 8 kV, 9 kV, and 10 kV. As the electrode speed increases, the number of micro-discharge channels decreases for all voltage amplitudes. For 8 kV and 9 kV, the number of micro-discharge channels decreases initially and then increases. While for 10 kV, the number of micro-discharge channels increases first and then decreases, with the decreasing trend slowing down over time. Additionally, the number of micro-discharge channels increases with the voltage amplitude, with the number at 10 kV significantly higher than at 8 kV and 9 kV.
The effect of varying voltage amplitude on the number of micro-discharge channels is shown in Fig. 4, which shows a quasi-uniform discharge distribution at lower voltages.
Under the combined influence of the external electric field and the electric field generated by space charge, the individual discharge channels remain relatively stable, achieving a dynamic equilibrium between them. However, as the increase of voltage amplitude, the electric field breaks the equilibrium between the microdischarge channels, leading to the fusion phenomenon between the channels, which transforms the discharge pattern into an inhomogeneous discharge distribution, and the number of microdischarge channels increases. Nevertheless, as the electrode rotational speed increases, the fusion between the microdischarge channels also rises, resulting in a decrease in their overall number.
As shown in Fig. 5, to better illustrate the effect of rotating electrodes on the number of microdischarge channels, the microchannel within a localized area was statistically analyzed. Points P and P′, located along the radial direction passing through the center O of the electrode, were selected. Using the segment PP′ as an axis, the number of microdischarge channels within the sector region traversed during the time interval Δt was studied. The distance r from any point in the arc to the center of the axis was measured, and the number of microdischarge channels N in this region was calculated. Assuming there are N microdischarge channels, each with a diameter l, the arc length of the region can be expressed as Nl. With the known rotational speed n ranging from 10 rpm to 100 rpm, the relationship between r and N is expressed by
As shown in Fig. 6, the number of microdischarge channels increases initially and then decreases as the distance from the electrode center increases. The number of micro-discharge channels near the electrode center increases with electrode rotation. At the electrode edge, the accumulation of charges causes stretching of the microdischarge channels, occupying more space and leading to a reduction in their number. The microdischarge channels at the edge of the electrode occupy space due to the accumulation of charge stretching, resulting in a decrease in the number. This decrease is further influenced by the edge effect, where the behavior differs from other regions.
-
Figure 7 shows the change of roundness of the micro-discharge channels morphology under different electrode rotational speeds, with an excitation frequency of 9 kHz and the characteristic parameter is roundness. Roundness Φ is typically used to indicate how closely an object approximates a perfect circle. In this study, roundness is employed to represent the stability of changes in micro-discharge channels morphology and to assess the degree of micro-discharge channels stretching. The formula is shown as follows:
where Rmax is the maximum value of the distance from all points on the profile to the center and Rmin is the minimum value of the distance from all points on the profile to the center. Raverage is the average of Rmax and Rmin.
In terms of the change of roundness in Fig. 7(a), under the voltage of 8 kV–10 kV, the roundness value gradually decreases with increasing electrode rotational speed, especially at 8 kV and 9 kV, the value of roundness is notably lower, indicating more severe shape distortion. Whereas, at 10 kV, the circularity value changes less with increasing electrode speed, indicating less shape variation, that is, better shape stability. At 8 kV and 9 kV, the discharge micro-discharge channels are significantly stretched in the direction of electrode rotation.
The variation in the average length of the micro-discharge channels was analyzed by taking rotational speeds of n = 10 rpm–100 rpm at 10 kV, as shown in Fig. 8. According to Eq. (2), the relationship between the micro-discharge channels length and the distance from the rotation center is derived.
From Fig. 8, it is observed that the average length of the micro-discharge channels increases as the distance from the rotation center increases. The discharge channels are gradually stretched along the radial direction and the relationship between r and l is proportional, as shown in Eq. (3). At a low rotational speed of n = 10 rpm, it can be seen that when the rotational speed is lower, closer to the rotation center, the micro-discharge channels tend to cluster together, leading to a larger average length, but as the increase of the distance from the rotation center, the average length of the micro-discharge channels first decreases and then increases.
This behavior can be explained by the gradual decrease in electric field strength as the distance from the rotation center increases weakening the electric field force acting on the micro-discharge channels during their formation, thus causing an increase in their average length. Considering that the elongated phenomenon may be the path travelled by the micro-discharge channels during the exposure time, according to the solution of Eq. (3), substitutingr = 40 mm, n = 10 rpm, the length of the path is 1 mm, substituting n = 100 rpm, the length of the path is approximately equal to 10 mm which is much larger than the average length corresponding to the r = 40 mm, n = 100 rpm in Fig. 8. This discrepancy indicates that the observed phenomenon is not merely the path travelled by the micro-discharge channels. Instead, it confirms that the micro-discharge channels are indeed stretched.
-
As shown in Fig. 9, the discharge image was captured at a peak supply voltage of 11 kV, a frequency of f = 9 kHz, and when the high-voltage electrode was stationary. It can be observed that when the high-voltage electrode is stationary, the spacing between neighboring micro-discharge channels is relatively large. Additionally, a phenomenon occurs where the micro-discharge channels tend to merges, resulting in a non-uniform discharge.
As shown in Fig. 10, a continuous discharge process was captured when the supply voltage peaked at 11 kV, the frequency was f = 9 kHz, and the high-voltage electrode rotated counterclockwise at high speed. The figure reveals that the micro-discharge channels are distributed in a band-like trajectory. In contrast to the discharge pattern at an electrode rotation speed of n = 0 rpm, the discharge mode transforms to a quasi-uniform distribution at n = 100 rpm.
As the rotational speed of the high-voltage electrode increases, the rotating dielectric barrier discharge distribution pattern transforms from inhomogeneous to quasi-uniform discharge. At low rotational speeds, the charge distribution within the medium is uneven, potentially concentrating in certain regions and leading to the formation of micro-discharge channels sticking points.[30] The uniformity of the DBD is largely influenced by the applied electric field within and outside the discharge gap,[31] and the rotation of high-voltage electrode enhances the uniformity of the electric field. Increasing the rotational speed of the high-voltage electrode enhances the uniformity of the electric field. As the rotational speed rises, the electric field is influenced by the rotation, resulting in a more uniform distribution of the electric field throughout the dielectric and causing transformation of the discharge pattern toward quasi-uniform discharge.[32]
3.1. Image texture feature processing
3.2. Mechanism of the effect of electrode speed on the number of micro-discharge channels
3.3. Effect of electrode rotation speed on morphology of micro-discharge channels
3.4. A shift in the distribution pattern of rotating DBDs
-
For the rotating DBD electrode structure, after applying the voltage, the gas in the electrode gap generates free electrons under the ionization effect due to the presence of the electric field force, and under the action of the applied power supply, the free electrons are moved towards the anode by the electric field, resulting in the collisional ionization, which generates new free electrons and positive ions. The newly generated free electrons undergo new collisional ionization in the process of movement, thus causing an instantaneous increase in the number of free electrons and the formation of an electron collapse.[33]
The free electrons move rapidly and converge at the front end, while the positive ions move more slowly and accumulate at the tail end. This difference in movement speeds creates space charges distortions that affect the electric field distribution, resulting in a stronger electric field region at the head of the electron avalanche.[34] As the electron avalanche develops to the dielectric plate of high-voltage electrode, the electrons and positive ions combine in the vicinity of the dielectric plate, leading to a significant amount of spatial photoionization.[35] This process triggers a secondary electron avalanche that merges with the tail of the original electron avalanche. The head of the new electron avalanche contains negative ions, while the tail of the original electron avalanche contains positive ions. These regions penetrate each other to form a plasma channel characterized by mixed ion properties. This positive streamer continues to develop by consistently triggering new avalanches, ultimately establishing a conductive fine ionization channel between the two dielectric plates. The formation of fine ionization channel is referred to as the ‘micro-discharge channel’.[36]
Under atmospheric pressure, discharge begins when the applied voltage exceeds the breakdown threshold. As shown in Figs. 11 and 12, when the high-voltage electrode rotates at low speeds, streamer breakdown occurs, and the streamer spans the discharge gap in nanoseconds, forming multiple irregularly distributed discharge channels. When the high-voltage electrode rotates at a low speed, a streamer breakdown occurs, and the streamer spans the entire discharge gap within a few or tens of nanoseconds and forming multiple irregularly distributed discharge channels. The discharge presents a series of separated discharge channels, resulting in uneven charge distribution in the air gap of the rotating dielectric barrier discharge actuator.[37] Consequently, charges accumulate in certain regions, increasing the local electric field strength and resulting in an uneven electric field distribution. When a micro-discharge channel first occurs at a certain place on the surface of the dielectric layer to form a micro-streamer channel, due to the side inhibition effect of the streamer in the development process, the adjacent regions near the discharge region lack charge accumulation, making it difficult to form new micro-discharge channels. This phenomenon leads to the non-uniformity of the discharge. As the rotational speed increases, the evolution shown in Fig. 11 indicates that both the electric field and the discharge channels are influenced by the rotation, resulting in a more uniform electric field distribution in the gap and a shift in the discharge mode to quasi-uniform discharge. In this quasi-uniform discharge state, the discharge channels uniformly cover the entire electrode surface. This transition in the discharge mode is consistent with those of Ref. [38], which studied the conversion of discharge forms using micro-gap hydroelectric electrodes.
The changes in the number and shape of micro-discharge channels are related to the electrode rotational speed. As the electrode rotational speed increases, charges accumulate on the dielectric surfaces of the high-voltage electrode and ground electrodes. The accumulated charges enhance the electric field on the surface of that side, which increases the spatial conductivity and the probability of pre-ionization at the location (charge accumulation area A and charge accumulation area B in Fig. 11), making it easy for the next discharge to reoccur in the vicinity of the charge accumulation area. When the high-voltage electrode rotates, the high-voltage side charge accumulation region A is transferred to A′ along the direction of rotation, and A′ creates a positional offset from the low-voltage side charge accumulation region B. The charge accumulation region B of the ground electrode provides a large number of seed electrons, making the discharge susceptible to lateral development along the straight-line A′B where the two charge accumulation regions are located. The strong field is more likely to excite air ionization, making the discharge susceptible to develop along A′B′, which is both stretched along the direction of rotation. As can be seen from Fig. 8, the degree of stretching of the discharge channel is related to its position. Specifically, the further the channel is from the center of the electrode, the greater the linear velocity, resulting in more pronounced stretching of the channel. This is because at higher linear velocities, the electric field force acting on the micro-discharge channels during its formation is weakened, which leads to an increase in the average length of the micro-discharge channels. Consequently, the stretching effect becomes more noticeable. As shown in Fig. 11, the electrode rotation makes the micro-discharge channels stretch. This morphological change is consistent with the phenomenon observed in the atmospheric pressure argon plasma jet, where the discharge channel undergoes a twisting and stretching effect when a sliding arc is generated by rotating the electrode, as reported in Ref. [39].
Figure 12 shows the SSZN SH3-103 high-speed camera captured the discharge process at a peak supply voltage of 11 kV and a frequency of 9 kHz for the high-voltage electrode in the stationary and rotating states. The exposure time of the camera is 16 μs. Given a cycle time T is 1/9000 s, 7 consecutive images were obtained per cycle.
As shown in Fig. 12(a), when the high-voltage electrode is stationary, the discharge channel exhibits a saturated circular shape with a circularity close to 1. This observation is consistent with the discharge results presented in Fig. 9. As shown in Fig. 12(b), the discharge channel on the inner side of the rotating center is saturated circular, and the discharge channel on the external side is stretched, with circularity less than 0.2. This corresponds to the discharge results in Fig. 10, indicating that the higher linear velocity of the external side discharge channel weakens the electric field force during its formation. Consequently, the average length of the micro-discharge channels increases.
On the dielectric surface of high-voltage electrode, charges move along the direction of rotation to reach a new position A′. This movement corresponds to the path of the ground electrode BB′. The accumulated charges on the dielectric surface of the high-voltage electrode induce the formation of new charges. Considering that the accumulated charges on both sides of the dielectric surface enhance the electric field in the vicinity, micro-discharge channels are generated along two straight-line positions, AB and A′B′, as shown in Fig. 13. This indicates that the rotation of the electrode increases the number of micro-discharge channels. This phenomenon of an increased number of micro-discharge channels are consistent with the change in the number of micro-discharge channels observed with cathode electrode rotation, as reported in Ref. [40].
-
This paper carried out an experimental study of the high-voltage electrode rotating dielectric barrier actuator, and obtained the following conclusions in response to the change in the overall characteristics of the discharge distribution of the micro-discharge channels in the discharge image, and the change in the parameters of the micro-discharge channels.
(i) The high-voltage electrode rotates at a low speed, and the discharge channel is a series of separated discharge channels, resulting in a uniform distribution of charges in the gap and an uneven distribution of electric field. As the rotational speed increases, the electric field and the discharge channels are affected by the rotation, so that the electric field is distributed more uniformly in the gap and the discharge pattern changes to quasi-uniform discharge.
(ii) As the distance from the center of the rotation axis increases, the electric field strength gradually decreases, and the electric field force suffered by the micro-discharge channels in the formation process is weakened, resulting in an increase in the average size of the micro-discharge channels, that is, the micro-discharge channels are gradually stretched.
(iii) The number of micro-discharge channels increases first and then decreases. The rotation of the electrode produces a large number of accumulated charges, which affects the number of micro-discharge channels. The number of micro-discharge channels in the middle of the electrode increases with the increase of rotational speed, and the average size of the micro-discharge channels at the edge of the electrode increases due to the stretching of the channels, which leads to a decrease in the number.