2026 Volume 35 Issue 5
Article Contents

M’bark Amghar, Noura Chabar, Amjad Sohail, Mohamed Amazioug. Generating three transparency windows, Fano-resonance, and slow/fast light in magnomechanical system through an auxiliary microwave cavity[J]. Chinese Physics B, 2026, 35(5): 050306. doi: 10.1088/1674-1056/ae1c2f
Citation: M’bark Amghar, Noura Chabar, Amjad Sohail, Mohamed Amazioug. Generating three transparency windows, Fano-resonance, and slow/fast light in magnomechanical system through an auxiliary microwave cavity[J]. Chinese Physics B, 2026, 35(5): 050306. doi: 10.1088/1674-1056/ae1c2f

Generating three transparency windows, Fano-resonance, and slow/fast light in magnomechanical system through an auxiliary microwave cavity

  • Received Date: 04/09/2025
    Accepted Date: 20/10/2025
    Available Online: 01/05/2026
通讯作者: 陈斌, bchen63@163.com
  • 1. 

    沈阳化工大学材料科学与工程学院 沈阳 110142

  1. 本站搜索
  2. 百度学术搜索
  3. 万方数据库搜索
  4. CNKI搜索

Figures(9)

Article Metrics

Article views(254) PDF downloads(0) Cited by(0)

Access History

Generating three transparency windows, Fano-resonance, and slow/fast light in magnomechanical system through an auxiliary microwave cavity

Abstract: In this paper, we propose a theoretical scheme to investigate the magnomechanically induced transparency (MMIT) phenomenon, Fano resonances, and slow/fast light effects in a hybrid cavity magnomechanical system. The magnomechanical system consists of two cavities: the principal cavity contains two ferromagnetic yttrium iron garnet (YIG) spheres, and the auxiliary cavity contains an atomic assembly. These two cavities are connected via photon tunneling, with the principal cavity being driven by two electromagnetic fields. The photon-magnon and phonon-magnon couplings are responsible for the magnon-induced transparency (MIT) and MMIT observed in the probe output spectrum. Furthermore, we examine the impacts of tunneling coupling, atom-photon coupling, and the magnetic field on the absorption, dispersion, and transmission spectra. We provide an explanation of the mechanism behind the Fano resonance phenomenon. Additionally, we address the phenomenon of slow and fast light propagation. Moreover, we demonstrate that the group delay of the probe field can be enhanced by increasing the photon tunneling strength. We also show that the slow light profile is reduced by adjusting the atom-photon coupling strength. This model is experimentally feasible, and we anticipate that these findings have potential applications in quantum information processing and communication.

1.   Introduction
  • Electromagnetically induced transparency (EIT)[1–4] is a quantum interference phenomenon observed in multi-level atomic systems. It arises when these systems are subjected to intense laser fields, resulting in the suppression of absorption for a weak probe light. Initially predicted by Harris et al.[2] and experimentally demonstrated by Boller et al.[3] using strontium vapor, EIT has become a widely researched phenomenon. This research has unveiled various novel occurrences, such as quantum memories for photons,[5,6] slow light,[7,8] enhanced nonlinearity,[9] vibrational cooling,[10] optical switches,[11] and multiple EITs with two or more transparency windows.[12–16] Typically, multiple EITs arise in systems with coherent multi-channels, enabling prolonged nonlinear interactions between weak fields, and have been proposed as a method to coherently control photon-photon interactions.[17]

    Optomechanically induced transparency (OMIT), a phenomenon analogous to EIT, was first explored in 2010 by Weis et al.[10] within vibrational cavity optomechanical systems. This effect emerges due to destructive interference among various internal field pathways in the system, creating a transparency window for probe light in spectral regions that would typically exhibit strong absorption.[18] This phenomenon has been proposed for use in various applications, including ultra-slow light propagation,[19] quantum routers,[20] precision measurement,[21] and four-wave mixing.[22] So far, the emergence of various new cavity optomechanical systems has led to theoretical research on the multiple-OMIT phenomenon. This research includes multiple-resonator optomechanical systems,[23] hybrid piezo-optomechanical cavity systems[24,25] and atomic-media-assisted optomechanical systems,[26,27] single-photon emitters,[28] Bose–Einstein condensates,[29] and nonlinear optomechanical systems,[30] among others.

    Recently, the cavity magnonic system (CMS) featuring a yttrium iron garnet (YIG) sphere has garnered significant interest, similar to the field of cavity optomechanics. This system offers numerous advantages over traditional systems due to the unique properties of magnetic materials, such as low damping rates, high spin density, and strong cooperativity with microwave photons.[31–36] These characteristics make CMS an ideal platform for studying strong light-matter interactions. Moreover, magnons have excellent coupling capabilities with various quantum systems, including optical photons, microwaves,[37] optical whispering gallery modes (WGMs),[38] superconducting qubits,[39] and phonons.[40] Due to these characteristics, YIG systems are employed to investigate a variety of coherent phenomena similar to those observed in optomechanical systems. These phenomena include ground-state cooling of magnomechanical resonators,[41] quantum entanglement,[42–45] magnomechanically induced transparency (MMIT),[46–49] as well as the engineering of slow and fast light,[48–52] and the phenomena of bistability and nonreciprocity.[53,54]

    In their CMS research, Ullah et al.[49] explored various intriguing quantum effects by exploiting the nonlinearity of magnetostrictive interactions in a system of two ferromagnetic YIG spheres coupled to a single microwave cavity mode. They demonstrated MMIT and magnon-induced transparency (MIT).[48,49,55] In addition, they observed the emergence of Fano resonance in the probe field.[56–58] They also reported slow and fast light propagation. Liao et al.[48] studied MMIT as well as slow and fast light effects in a system comprising a high-quality YIG sphere and an atomic ensemble, both located inside a microwave cavity. Recently, Liu et al.[59] suggested a scheme for an auxiliary-microwave-assisted coupled magnomechanical model (AMCA) involving two YIG spheres. They introduced a mechanism for simultaneously enhancing quantum cooling and entanglement by coupling an auxiliary microwave cavity to a magnomechanical cavity.

    In this paper, we investigate the MMIT phenomenon, Fano resonance, transmission, and slow and fast light effects in a magnomechanical system, which consists of two single cavities connected by single-photon hopping and includes an atomic ensemble and two YIG spheres (see Fig. 1). We investigate the effect of the photon hopping coupling strength, atom-photon coupling strength, and the magnetic field on the absorption and dispersion spectra. Moreover, we study Fano resonances in the output probe field. Additionally, we explore slow and fast light propagation, clarifying that the group delay is influenced by the tunability of the photon hopping coupling strength, as well as the atom-photon coupling.

    The organization of this paper is delineated as follows: Section 2 introduces the system, presents the formula for its Hamiltonian, and outlines the relevant quantum Langevin equations (QLEs) while calculating the output field. In Section 3, we examine magnomechanically induced transparency and analyze how the photon hopping coupling strength f, atom-photon coupling strength, and magnetic field affect the input spectrum. Section 4 focuses on the study of Fano resonance in the output field. Section 5 describes the transmission of the probe field and evaluates the group delays related to slow and fast light propagation. In Section 6, we examine the feasibility of our system using current experimental parameters and configurations. Finally, the paper concludes with concluding remarks.

2.   Model
  • In the hybrid coupled-cavity magnomechanical system depicted in Fig. 1, we consider two single-mode cavities connected by single-photon hopping f, each with resonance frequencies ωr (r = 1, 2), including an atomic ensemble and two YIG spheres. This interconnected system includes six excitation modes: microwave electromagnetic modes in cavity A and cavity B, phonon and two magnon modes in the YIG sphere, and atomic excitation within cavity B.

    In cavity A, each sphere is subjected to a uniform magnetic field along the z-direction, which excites magnonic modes. These modes are coupled to the cavity A field via dipolar magnetic interactions. Excitation of the magnonic modes inside a sphere results in fluctuating magnetization, which in turn induces changes in the lattice structure. The magnetostrictive force generates vibrations in the YIG spheres, leading to interactions between magnons and phonons within these spheres. The strength of the single-magnon magnomechanical coupling is notably weak[57] and depends on both the diameter of the sphere and the orientation of the external polarization field. By considering a larger n1 sphere, or by changing the orientation of the polarizing magnetic field applied to it, the magnomechanical coupling of this sphere can be neglected.[45] In this context, we assume that the orientation of the polarizing field on the n1 sphere is configured so that the single-magnon magnomechanical interaction is extremely weak and can be ignored.[57] Nevertheless, the magnomechanical interaction of the n2 sphere is significantly enhanced by the direct excitation of its magnon mode through an external microwave actuator. This microwave driver functions as the control field within our model. Furthermore, cavity A is driven by a weak probe field.

    Within cavity B, an ensemble comprising N two-level atoms, characterized by a transition frequency ωu, interacts with the cavity field. Each atom in the ensemble is described by spin-1/2 Pauli matrices σ+, σ−, and σz. The collective spin operators associated with atomic polarization are represented as S+,−,z=∑i=1Nσ+,−,zi. These operators satisfy the commutation relations: [S+, S−] = Sz and [Sz, S±] = ±2S±.[60,61] The operators S± and Sz can be expressed in terms of bosonic annihilation and creation operators u and u† via the Holstein-Primakoff transformation[61–64]

    where [u, u†] = 1. This transformation is valid under the condition that the population of atoms in the ground state greatly exceeds that in the excited state, ensuring Sz ≈ 〈Sz〉 ≈ −N.[65]

    We model the system using high-purity YIG spheres of 250 μm in diameter, containing ferric ions (Fe3+) with a number density ρ = 4.22 × 1027 m−3. The corresponding total spin is S=52ρV=7.07×1014, where V is the YIG volume. The collective spin operator S satisfies the standard commutation relations [Sα,Sβ]=iεαβγSγ. The complete Hamiltonian characterizing the system is

    The first four terms of Eq. (1) represent the energies of cavities A and B, atomic excitation, magnon (n1 and n2) modes, and the phonon mode. Here, ωr are the cavity resonance frequencies, ωu is the atomic transition frequency, ωnr are the magnon frequencies, and ωp is the phonon frequency. Notably, ωnr = γHr can be tuned via the external bias magnetic field Hr. The operators ar(ar†), u(u†), nr(nr†), and p(p†) satisfy canonical commutation relations: [ar,ar†]=1, [u, u†] = 1, [nr,nr†]=1, and [p, p†] = 1.

    The next four terms describe intersystem couplings: magnon-phonon (gnp), cavity-cavity (f), atom-cavity (Gau), and cavity-magnon (gr). The collective atom-cavity coupling is Gau=hN, where h=νω2/(2ħε0V), ν is the atomic dipole moment, V is the cavity volume, and ε0 is the permittivity of free space. The penultimate term represents a probe field driving cavity A, with amplitude εd=2κaPd/(ħωd) and frequency ωd. The last term describes a microwave drive on the magnon mode n2 with Rabi frequency Ω=54γNB, where B is the drive amplitude and γ = 28 GHz/T is the gyromagnetic ratio.[66]

    In Eq. (1), we neglect the nonlinear term Knr†nr†nrnr, which could arise from strongly driven magnon modes.[54] This is justified if K |〈n2〉|3 ≪ Ω, which holds for the parameters considered here. In the rotating frame of the drive frequency ω0 and within the rotating-wave approximation, the Hamiltonian becomes

    where Δr = ωr – ω0, Δu = ωu – ω0, Δnr = ωnr - ω0, and δ = ωd – ω0.

    The Heisenberg–Langevin equations are then

    Here, κa, γu, κnr, and κp are the dissipation rates of cavities, atomic ensemble, magnon modes, and phonon mode, respectively. arin, pin, uin, and nrin are vacuum input noise operators with zero mean.[67] The strong drive on n2 yields a large steady-state amplitude |〈n2s〉| ≫ 1, leading also to a large cavity amplitude |〈a1s〉| ≫ 1. Linearizing around the steady state, we expand operators as ℛ=ℛs+ℛ−e−iδt+ℛ+eiδt, with ℛ=a1,a2,n1,n2,u,p.[68] The zero-order steady-state solutions are

    Assuming that the coupling between the external microwave drive and the magnon mode n2 is significantly stronger than the probe field amplitude εd, we solve the linearized quantum Langevin equations by considering only the first-order perturbed solutions and neglecting higher-order terms in εd. The cavity mode solution is then

    where

    Here, GA=Gnp/2 with Gnp=i2gnpn2s being the effective magnomechanical coupling. Using the standard input-output relation for cavity A,[69] the amplitude of the output field is

    The real part Re[εout] corresponds to the absorption spectrum, while the imaginary part Im[εout] corresponds to the dispersion spectrum.

    The steady-state magnon amplitude n2s from Eq. (4) can be written ase

    with

    In Fig. 2(a), the steady-state magnon number is plotted as a function of the driving magnetic field B under different tunneling coupling strengths. The magnon number increases with B, but decreases with increasing inter-cavity coupling f for a fixed B. In Fig. 2(b), the steady-state magnon number is shown under different atom-photon coupling strengths. The magnon number decreases with increasing Gau when B is fixed.

3.   Magnomechanically induced transparency
  • In this section, we numerically examine the influence of the cavity–cavity coupling strength f, atom-photon coupling strength Gau, and the magnetic field B on magnomechanically induced transparency within a double-cavity magnomechanical system. We utilize the effective parameters derived from recent experiments on cavity magnomechanical systems,[57,66] such as: ω1,2 / 2π = 10 GHz, ωp / (2π) = 10 MHz, κp / (2π) = 100 Hz, ωn1,n2 / (2π) = 10 GHz, κa / (2π)=2.1 MHz, κn1 / (2π) = κn2 / (2π) = 0.1 MHz, g1 / (2π) = g2 / (2π) = 1.5 MHz, Gnp / (2π) = 3.5 MHz, Δ1,2 = ωp, Δn1,n2 = ωp, and ω0 / (2π) = 10 GHz. Accordingly, the atom-cavity coupling and atomic decay rate are on the order of megahertz, with Gau / (2π) = 6 MHz and γu / (2π) = 1 MHz.[70] Moreover, the hopping rate f between the cavities is also on the order of megahertz.

    In Figs. 3(a)–3(c), we display the absorption spectrum Re[εout] of the probe field as a function of the normalized probe detuning δ / ωp for different values of the cavity–cavity tunneling coupling f and the couplings g1, g2, and Gnp, with the atom-cavity coupling set to zero (Gau = 0). In Fig. 3(a), both the magnon-phonon coupling (Gnp) and the magnon-photon coupling (g1) are disabled; as a result, cavity A is coupled only to the magnon mode n2. Under these conditions, a single transparency window appears, referred to as the MIT window. When the magnon-phonon coupling (Gnp) is activated and g1 remains zero, a second transparency window emerges, associated with the magnon-phonon interaction, called the MMIT window, as shown in Fig. 3(b). When g1 is also activated, three transparency windows are observed: the single MIT window shown in Fig. 3(a) splits into a double MIT window and an MMIT window, as illustrated in Fig. 3(c). This result is consistent with Ref. [49].

    We observe that the absorption peaks decrease with increasing tunneling coupling strength f, resulting in a shallower transparency window. Moreover, as f increases, the transparency window broadens and deepens. These results indicate that increasing the cavity–cavity coupling reduces absorption, enhancing the MMIT effect and, consequently, improving quantum interference. This behavior is qualitatively similar to OMIT.[71]

    In Figs. 3(d)–3(f), we show the dispersion spectrum Im[εout] of the probe field as a function of the normalized detuning δ / ωp for different values of the cavity–cavity tunneling coupling f and coupling strengths g1, g2, and Gnp with Gau = 0. A single MIT dispersion spectrum appears when only the magnon-photon coupling (g2) is present, as illustrated in Fig. 3(d). Figure 3(e) shows the dispersion spectrum for the case g1 = 0, Gnp ≠ 0, and g2 ≠ 0. Figure 3(f) depicts the dispersion spectrum when all three couplings are activated. It can be seen that the dispersion slope decreases with increasing tunneling coupling f, indicating that stronger tunneling enhances quantum interference and reduces the dispersion around the transparency window.

    In Figs. 4(a)–4(c), we plot the absorption spectrum Re[εout] as a function of the normalized detuning δ / ωp for various values of the atom-photon coupling Gau, with f = 0.15 ωp and different combinations of g1, g2, and Gnp. Specifically, one, two, and three transparency windows appear under the following conditions: (i) g1 = Gnp = 0 and g2 ≠ 0; (ii) g1 = 0, Gnp ≠ 0, and g2 ≠ 0; and (iii) g1 ≠ 0, Gnp ≠ 0, and g2 ≠ 0, respectively. The curves corresponding to Gau = 0, 3, 4, and 6 MHz are shown in black, red, green, and magenta, respectively. We note that the absorption peaks increase with larger Gau. Physically, a stronger atom-photon coupling enhances the interaction between cavity photons and the atomic ensemble, leading to more pronounced absorption peaks and reduced quantum interference, consistent with Ref. [48].

    Figures 4(d)–4(f) show the corresponding dispersion spectra Im[εout] as a function of δ / ωp for the same parameter sets. Figure 4(d) exhibits a single MIT dispersion spectrum in the absence of g1 and Gnp. Figure 4(e) corresponds to g1 = 0, Gnp ≠ 0, and g2 ≠ 0, while Fig. 4(f) shows the dispersion when all three couplings are present. The results demonstrate that the dispersion slope increases with increasing Gau.

    In Fig. 5, we depict the absorption spectrum of the probe field as a function of normalized detuning δ / ωp for various values of the applied magnetic field B. Increasing B broadens the transparency windows and increases the peak separations, while shifting the windows toward lower probe frequencies. Moreover, the peak absorption decreases and the window becomes wider, eventually leading to the disappearance of the absorption feature.

4.   Fano resonances in the output field
  • In this section, we will explore the Fano resonances present in the output spectrum. The shape of the output spectrum characterized by the Fano resonance is clearly different from the symmetrical resonance curves observed in the EIT, OMIT, MIT and MMIT windows.[57,58] In systems exhibiting optomechanical-like interactions, Fano resonance arises from the existence of non-resonant interactions. In our system, this non-resonant interaction is observed as the magnon mode couples to the phonon mode via an optomechanical-like interaction, where we apply the condition Δn1,n2 ≠ ωp. We see in Figs. 6(a) and 6(b) asymmetrical Fano shapes with Δn1,n2 ≠ ωp for different f and Gau, where the absorption spectrum of the output field is shown as a function of the normalized detuning δ / ωp. In Fig. 6(a), we have fixed the atom-photon coupling at Gau = 0. Owing to the presence of a non-resonant process Δn1,n2 = 0.8 ωp, the absorption spectrum evolves from a symmetric MMIT profile (Fig. 3(c)) into an asymmetric-window profile for different value of f, as illustrated in Fig. 6(a). From Fig. 6(b), in the presence of the all couplings and with the presence of the non-resonant process Δn1,n2 = 0.8 ωp, we observe three Fano resonances. This means that the absorption spectrum changes from a symmetrical MMIT profile (Fig. 4(c)) to an asymmetrical window profile for different Gau.

5.   Transmission and slow/fast light
  • In this section, we investigate the impact of the cavity–cavity tunneling coupling f and atom-photon coupling Gau on the transmission and group delay of the output field. The transmission of the probe field is defined as the ratio of the amplitudes of the output field to the input field at the probe frequency, as given by the following expression:[46,72]

    We plot in Fig. 7(a) the transmission spectrum |t|2 as a function of the normalized detuning δ / ωp for several values of the tunneling coupling f with Gau = 0. This figure shows three transparency windows when all couplings are simultaneously nonzero. The transmission peaks increase with increasing tunneling coupling f. For instance, when f = 0.15 ωp, the transmission peaks at δ / ωp ≃ 0.90, δ / ωp ≃ 1, and δ / ωp ≃ 1.07 are |t|2 = 0.61, |t|2 = 0.60, and |t|2 = 0.63, respectively. In contrast, for f = 0.35 ωp, the peaks are |t|2 = 0.67, |t|2 = 0.66, and |t|2 = 0.68.

    We plot in Fig. 7(b) the transmission spectrum |t|2 versus the normalized detuning δ / ωp for different values of the atom-photon coupling Gau with f = 0.15 ωp and g1 / (2π) = g2 / (2π) = Gnp / (2π) = 1.2 MHz. The transmission peaks decrease as Gau increases. For example, when Gau = 0, the peaks at δ / ωp ≃ 0.90, δ / ωp ≃ 1, and δ / ωp ≃ 1.07 are |t|2 = 0.595, |t|2 = 0.579, and |t|2 = 0.616, respectively. In contrast, for Gau / (2π) = 1.5 MHz, the peaks reduce to |t|2 = 0.580, |t|2 = 0.567, and |t|2 = 0.601.

    We define the rapid phase dispersion Φ = Arg[t] within the narrow transparency window. This dispersion induces a group delay, given by[73]e

    A positive group delay (τ > 0) indicates slow light propagation, whereas a negative group delay (τ < 0) indicates fast light propagation.

    Figure 8(a) shows the group delay τ as a function of the normalized detuning δ / ωp for different values of the tunneling coupling f with Gau = 0 and Gnp / (2π) = g1 / (2π) = g2 / (2π) = 1.2 MHz. We observe that when cavity A is not coupled to cavity B, i.e., f = 0, the group delay of the output probe field is always positive, with two peaks at δ = 0.93ωp and δ = 1.05ωp, indicating the slow-light effect experienced by the probe field. When cavity A is coupled to cavity B, i.e., f = 0.3ωp, a negative group delay is obtained at δ = 0.92ωp and δ = 1.05ωp, corresponding to the fast-light effect of the output probe field. In contrast, the positive group delay at δ = 0.71ωp, δ = 0.90ωp, δ = ωp, and δ = 1.07ωp corresponds to the slow-light effect. By increasing the tunneling coupling f, we observe an enhancement of slow light and a decrease of fast light. Therefore, the slow-light effect can be enhanced and the fast-light phenomenon suppressed by adjusting the tunneling coupling f. By comparing the transmission evolution in Fig. 7(a) with Fig. 8(a) for f = 0.3ωp, it is evident that the peaks (τ > 0) appear at ωd – ω0 = 0.71ωp and ωd – ω0 = 1.28ωp. At these points, the transmission transitions from absorption to transmission, leading to an increase in t within this region.

    In Fig. 8(b), we plot the group delay as a function of the normalized detuning δ / ωp for different values of Gau with f = 0.15ωp. We observe that the group delay of the output field is always positive and decreases with increasing atom-photon coupling Gau, indicating that only the slow-light phenomenon is observed. Comparing the transmission variation in Fig. 7(b) with the group delay in Fig. 8(b) for Gau / (2π) = 1.5 MHz, we find that the peaks (τ > 0) occur at ωd – ω0 = 0.93ωp and ωd – ω0 = 1.05ωp, where transmission switches from absorption to transmission. The adjustability of the group delay is attributable to the quantum interference between the probe field and the anti-Stokes field, indicating that the group delay can be dynamically tuned by regulating the cavity–cavity tunneling coupling f and the atom-photon coupling strength Gau.

    In Fig. 9(a), we plot the group delay τ as a function of the tunneling coupling strength f for various values of the atom-photon coupling strength Gau with g1 = 0, g2 / (2π) = 1.2 MHz, Gnp / (2π) = 1.2 MHz, and δ = ωp. We observe the emergence of slow and fast light for a given value of Gau. For example, for Gau = 0, the group delay is positive between f = 0 and f = 13.20 MHz, and negative between f = 13.20 MHz and f = 21.09 MHz. Additionally, the maximum group delay can be increased by adjusting Gau, with higher values of the atom-photon coupling leading to larger group delays.

    Figure 9(b) shows the group delay τ as a function of atom-photon coupling strength Gau for different values of the tunneling coupling strength f, with g1 = 0, g2 / (2π) = 1.2 MHz, Gnp / (2π) = 1.2 MHz, and δ = ωp. When cavity A is not coupled to cavity B, i.e., f = 0, the group delay is positive and fixed at τ = 0.5 μs. Conversely, when the tunneling coupling is present, i.e., f = 0.3ωp, the group delay exhibits two regions: a negative region between Gau = 0 and Gau = 9.27 MHz, indicating fast light, and a positive region for Gau> 9.27 MHz, indicating slow light. We note that the group delay τ increases significantly with the tunneling coupling strength f. The group delay is proportional to the slope of the dispersion curve in the transparency region (see Fig. 3(f)). As f increases, the slope becomes steeper due to enhanced coupling and interference between the two optical cavities, resulting in slower propagation of the probe field, corresponding to the slow-light effect.

6.   Feasibility
  • The feasibility of the proposed double-cavity magnomechanical system is supported not only by previously demonstrated subsystems but also by the realistic choice of parameters used in our numerical analysis. The system parameters are taken from recent experimental reports on cavity magnomechanical platforms.[57,66,70] Specifically, the cavity and magnon mode frequencies are ω1,2 / (2π) = ωn1,n2 / (2π) = 10 GHz, while the mechanical frequency is ωp / (2π) = 10 MHz. The corresponding decay rates are κa / (2π) = 2.1 MHz, κn1,n2 / (2π) = 0.1 MHz, and κp / (2π) = 100 Hz, all within experimentally accessible values.[49] The single-photon magnomechanical couplings g1,2 / (2π) = 1.5 MHz and the enhanced coupling Gnp / (2π) = 3.5 MHz have been experimentally achieved in hybrid cavity-magnon systems.[57] The atom-photon coupling Gau / (2π) = 6 MHz and atomic decay rate γu / (2π) = 1 MHz are also within the typical range of cavity quantum electrodynamics experiments.[70] Furthermore, the inter-cavity coupling rate f is assumed to be on the order of megahertz, which has been demonstrated in coupled cavity experiments. Therefore, all parameters employed in our theoretical calculations are within experimentally realistic ranges, confirming the feasibility of realizing the proposed magnomechanical-induced transparency phenomenon with current technologies.

7.   Conclusion
  • In conclusion, we have examined the absorption, dispersion, and transmission spectra of a hybrid magnomechanical system. MMIT and MIT can be identified in the absorption and transmission spectra as a result of photon-magnon and phonon-magnon interactions. The cavity–cavity tunneling coupling has the potential to enhance MIT and MMIT. Subsequently, we investigated the impact of the atom-photon coupling on the absorption and transmission spectra. The results indicate that the transparency windows decrease when the atom-photon coupling is increased. We also studied the influence of the magnetic field on the absorption spectrum. Additionally, the presence of anti-Stokes processes in the system gives rise to the Fano resonance phenomenon, which is thoroughly examined. We have studied the conditions for slow and fast light propagation in our system, which can be regulated by various system parameters. It was demonstrated that the tunability of the tunneling coupling and atom-photon coupling has a significant impact on the slow- and fast-light phenomena in our magnomechanical system.