Citation: Xu-Bo Liao, Yi Zhang, Qi-Yuan Jiang, Bing-Feng Sun, Sheng-Bing Shi, Shi-Yu Guan, Yu-Xiao Wang, Zhong-Qi Tan, Jie Yuan. Simulation study on the impact of microwave pulses on performance of ensemble nitrogen-vacancy centers[J]. Chinese Physics B, 2026, 35(8): 080701. doi: 10.1088/1674-1056/ae24e9

Simulation study on the impact of microwave pulses on performance of ensemble nitrogen-vacancy centers

  • Received Date: 24/08/2025
    Accepted Date: 17/11/2025
    Available Online: 01/08/2026
通讯作者: 陈斌, bchen63@163.com
  • 1. 

    沈阳化工大学材料科学与工程学院 沈阳 110142

  1. 本站搜索
  2. 百度学术搜索
  3. 万方数据库搜索
  4. CNKI搜索

Figures(11)  /  Tables(3)

Article Metrics

Article views(62) PDF downloads(1) Cited by(0)

Access History

Simulation study on the impact of microwave pulses on performance of ensemble nitrogen-vacancy centers

Abstract: This study is conducted to establish a reliable simulation model for investigating the impact of microwave pulses on the performance of an ensemble nitrogen-vacancy (NV) center system, thereby providing a basis for optimizing microwave parameters and enhancing quantum sensing performance. The simulation of ensemble NV centers is realized through the design of “Single NV Center Module” + “Ensemble Control Module”. Verified by optically detected magnetic resonance (ODMR), Ramsey, and Hahn echo experiments, the program can accurately reproduce the core characteristics of the experiments, confirming the reliability of the model. Using this model to study the influence of microwave spatial inhomogeneity on system performance, it was found that when θ (the range of microwave axial distribution) is 90°, the sensitivity of the Hahn echo decreases by 3.6 times, and when the amplitude gradient is 50 μT/mm, the sensitivity decreases by 1.8 times, providing quantitative support for optimizing microwave parameters.

1.   Introduction
  • Negatively charged nitrogen-vacancy centers have been extensively studied and applied in fields such as quantum computing, quantum information, magnetic field measurement, and nano-imaging, owing to their significant advantages including room-temperature stability, long quantum coherence time, optical addressability, and biocompatibility.[1–3] The measurement sensitivity of the NV center system is closely related to its coherence, and noise can cause a significant decay of system coherence, thereby reducing measurement performance.[3]

    The energy level structure of NV− centers in diamond is shown in Fig. 1. In addition to the three Zeeman levels of the ground state 3A2 and the excited state 3E, it also contains two metastable states, 1A1 and 1E. This allows electrons in the excited state to return to the ground state through non-radiative intersystem crossing (ISC) processes, in addition to spontaneous radiative transitions.[3–5] Since the probability of intersystem crossing in the |ms = ±1⟩ excited state is higher than that in the |ms = 0⟩ state, the population of different spin states can be distinguished by the intensity of spontaneously emitted fluorescence. An applied magnetic field will lift the degeneracy of the |ms = ±1⟩ energy levels. Through 532-nm laser pumping, spontaneous emission, and the ISC process, electrons accumulate in the ground state |ms = 0⟩ energy level. The pumping rate Γp is used to represent the rate of transition from the ground states |ms = ±1⟩ to |ms = 0⟩. Neglecting the influence of the excited state 3E and the metastable states 1A1 and 1E, the system can be simplified and described using a three-level model.

    In the study of diamond NV centers, the coherence decay characteristics of spin systems are typically characterized by T2* and T2.[6]T2* is the spin free induction decay time (also known as dephasing time), which describes the decay of phase coherence in a spin system under the combined action of static inhomogeneous magnetic fields and dynamic noise. Its rapid decay stems from external static magnetic field inhomogeneities (such as magnetic field gradients) and internal dynamic noise (such as spin bath fluctuations). T2 is the spin-spin relaxation time (also known as decoherence time). The difference from T2* is that the influence of static magnetic field inhomogeneity can be eliminated through pulse sequences such as spin echo, which only reflects the decay of spin coherence under the action of dynamic noise. Generally, T2*≪T2, near-surface NV centers have T2* values of only 3 μs ∼ 50 μs.[3] After spin-echo processing, T2 can be improved to 100 μs ∼ 200 μs,[7,8] while dynamic decoupling sequences (e.g., CPMG, XY8) can further suppress noise from spin baths and other dynamic sources, extending T2 to the millisecond level. T2 is a core metric for evaluating quantum sensor performance, directly determining the detection sensitivity.[1] For the ensemble NV centers system, the sensitivities of measuring the magnetic field by the continuous-wave ODMR (CW-ODMR), Ramsey, and Hahn echo methods are[9–11]

    where ħ/geμB is the basic constant term, ge ≈ 2.003 is the electronic g factor of the nitrogen-vacancy center, μB is the Bohr magneton, and ħ is the reduced Planck constant, R is the photon detection rate, Δυ is the linewidth of the ODMR spectrum, C is the signal contrast, α is the decay stretching exponent, and τ is the free precession time of each measurement, tI is the initialization time, and tR is the readout time. To extend to spins with higher multiplicities, the spin state difference Δms ≥ 2 for interferometric measurement is used. For negligible tI and tR, the optimal measurement times are τ=T2*/2 and τ = T2, respectively. N is the number of NV centers.[12] Equation (1) can be simplified as

    Based on the derivation using the density matrix and Schrödinger equation (see Appendix A), we obtain the time evolution relationship of the Ramsey signal in an ensemble NV centers system[10,13,14]

    The relationship between Hahn echo signal and time variation is given by[15]

    where S0 is the background fluorescence signal baseline, C is the contrast, ωx is the Rabi oscillation angular frequency, and α is a numerical factor related to the specific noise type. The stretched exponent α for Hahn echo decay varies between 0.5 and 3.[10,16]

2.   Methods
  • The density matrix evolution kinetic equation of the three-level model ρ.=f(ρ) is derived from the eigen-Hamiltonian. For the detailed derivation process, please refer to Appendix A. For the ensemble NV centers system, it is necessary to establish an output fluorescence intensity function. The fluorescence intensity is affected by multiple factors such as microwave power, microwave frequency, and magnetic field. The ensemble fluorescence intensity is composed of the superposition of the output fluorescence intensities of each single NV center in the system. Therefore, for the NV centers with different parameter gradients, the ensemble fluorescence intensity can be calculated by means of weighted average. The final expression of the system’s output fluorescence intensity is

    where ki is the light intensity weighting coefficient occupied by the NV center, and Σki = 1, Ii are the fluorescence intensities.

    We modularly design the ensemble NV center simulation model. The orange block on the right side of Fig. 2 in the structural block diagram is the single NV center simulation module. The physical effect module simulates physical effects such as pump light, external magnetic field, and microwave pulses respectively. The physical effect module regulates the system evolution by modifying Hamiltonian parameters. The main parameters include system parameters (longitudinal relaxation rate γ1, transverse relaxation rate γ2, and pump rate γp), magnetic field parameters (NV axial magnetic field Bz, magnetic field noise ΔBz), and microwave parameters (microwave magnetic field Bx, π pulse width tπ, pulse axial deviation θ, and microwave frequency ωx). The noise source module is used to generate magnetic field noise ΔBz. We mainly considered the presence of spin bath fluctuations around the NV center, which is the main cause of dephasing. In this paper, the Ornstein–Uhlenbeck (OU for short) process is used to generate random magnetic field noise ΔBz(t), with parameters including coupling strength b, correlation time τc.[15,17] The RK4 algorithm module is employed to solve the time evolution equation of the density matrix, thus ensuring the accuracy of numerical calculations. The signal acquisition module simulates the experimental measurement process and computes the observable quantities of the system. The fluorescence intensity reading module calculates the fluorescence signal based on the density matrix, thus realizing the connection between the theoretical model and experimental observation.

    The green block on the left side of Fig. 2 is the ensemble NV centers simulation module, which realizes the simulation of ensemble output characteristics by integrating multiple single NV center models. Among them, the ensemble control module provides differentiated parameter inputs for different single NV center modules by reasonably setting parameters such as light intensity weight, static magnetic field noise, microwave amplitude noise, and microwave frequency noise. The parameter distribution module generates the parameter distribution of each NV center in the ensemble. The parallel computing engine efficiently completes the parallel computing of a large number of NV centers. The ensemble result synthesis module integrates the calculation results of individual NV centers according to weights to obtain the ensemble average signal. This modular design endows the system with good scalability and maintainability, facilitating the subsequent integration of new physical effects or optimization of algorithms.

    We have built a cage-based optical system for diamond NV center experiments. By comparing the simulation results with the experimental output, we verify the reliability of the simulation model. The structure is shown in Fig. 3. The system consists of an optical module, a microwave module, a control and acquisition module, and a power supply module. The optical module includes a laser pulse generator, a cage-based optical setup, a microwave radiation structure, a diamond sample, and a photodetector. The microwave radiation structure adopts double split-ring resonators from CIQTEK.[18,19] The diamond sample DNVTMB1 is produced by Element Six, with dimensions of 5 mm×5 mm×0.5 mm. The laser is a 532-nm solid-state laser, and the maximum laser power is 100 mW. The laser pulse generator emits green laser light, which excites the NV centers to generate red fluorescence. After the fluorescence is filtered by a filter, it is focused by a lens onto a photodetector, which completes the conversion of optical signals to electrical signals and the reading of fluorescence intensity.

3.   Application and analysis
  • Under zero-field conditions, the system’s ODMR spectra were tested at microwave powers of 26 dBm, 23 dBm, 20 dBm, and 17 dBm, respectively (the microwave power here refers to the microwave power applied to the NV center sample after passing through the power amplifier, not the power value set at the microwave source). Through Rabi oscillation experiments, the corresponding Rabi frequencies ΩRabi were measured as 2.81 MHz, 1.99 MHz, 1.41 MHz, and 1.06 MHz, and the full width at half maximum (FWHM) Δυ of the spectrum under each state was obtained. When simulating the ODMR experiment, in order to approximate the characteristics of the real experimental system, the core parameters are set as γ1 = 1000 s−1, γ2 = 25000 s−1, γp = 50000 s−1. Specific parameter settings for the experiment and simulation are compared in Table 1. Based on the Rabi frequency obtained from the experiment, the corresponding microwave magnetic fields obtained through simulation inversion were 100 μT, 71 μT, and 38 μT, respectively. Then, the simulated ODMR spectra are plotted, and the result data are normalized. The comparison of the output curves of the experimental system and the simulation program is shown in Fig. 4.

    Adjust the microwave power so that the Rabi frequency is ΩRabi = 9.25 MHz, and set the microwave frequency to ωx = 2.87 GHz. In the simulation program, set the corresponding microwave magnetic field strength to Bx = 330 μT, and keep the rest of the parameters consistent with those in the ODMR experiment. Figure 5(a) shows the comparison of the Ramsey experiment results between the experimental system and the simulation program (the abscissa is the free evolution time, and the ordinate is the normalized fluorescence intensity). The red scatter curve is the output result of the experimental system, and the black solid line is the output result of the simulation program. The fitted dephasing times are T2real*=50.7ns and T2sim*=48.8ns.

    The Hahn echo experiment adopts the same parameter settings as the Ramsey experiment. Figure 5(b) shows the comparison of the Hahn echo experiment results between the experimental system and the simulation program (the abscissa is the free evolution time, and the ordinate is the normalized fluorescence intensity). The black scatter curve is the output result of the experimental system, and the red solid line is the output result of the simulation program. The fitted decoherence times T2real = 39.2 μs, T2sim = 39.9 μs. Based on the comparative results of the ODMR experiment, Ramsey experiment, and Hahn echo experiment, the simulation program designed in this paper can accurately reproduce the core characteristics of the experimental system.

  • In the diamond NV center sample, there are four NV axes α, β, γ, δ, and the angle between each pair of these four axes in space is 109°.[20] The relative positional relationship between different axes in the ensemble within a magnetic field is shown in Fig. 6(a). To simplify the research, we assume that the static magnetic field Bz is parallel to the α-axis, and the microwave field BMW is perpendicular to the α-axis.

    Owing to the hyperfine coupling between the electron spin of the NV center and the 14N nuclear spins (I = 1), the resonance peak after the Zeeman splitting of the NV center is further split into three hyperfine peaks with a peak interval of 2.2 MHz.[15,21] Figure 7(a) shows the ensemble ODMR spectrum when Bz = 11.4 mT, BMW = 50 μT. Since the static magnetic field has equal angles with the axes β, γ, δ, its projections onto these axes are equal, so the resonance peaks completely overlap, ultimately presenting 2 pairs of resonance peaks, which are the resonance peak of the NV-α and the superimposed resonance peaks of the NV-β, γ, δ. Zooming the α-axis resonance peak at a microwave frequency of 2550 MHz reveals three hyperfine peaks with unequal intensities, and their resonance frequencies correspond to 2548.3 MHz, 2550.5 MHz, and 2552.7 MHz, respectively. Its mechanism is that when the static magnetic field meets the polarization transfer threshold, the laser polarizes the NV electron spins, and the electron spins indirectly polarize the 14N nuclear spins through hyperfine coupling, resulting in population bias. Here, we refer to De Lange G 2010 Science 330 60–3, where the population ratio of 14N nuclear spins on each energy level (mI = |+1⟩, |0⟩, |−1⟩) is 5:3:2.[15,20] In the simulation, we achieve this by setting magnetic field offsets and light intensity weighting coefficients.

    In contrast, in Fig. 7(b), when Bz = 2 mT, BMW = 50 μT, the population of nuclear spins in each energy level tends to be equal, showing three hyperfine peaks with equal intensities. Figure 6(b) shows that the microwave field has axial inhomogeneity in space, and its influence on the output characteristics of the ensemble is discussed in Subsection 3.2 of this paper. Figure 6(c) shows that when the static magnetic field has unequal angles with the four NV axes, the ODMR spectrum in Fig. 7(c) presents 4 pairs of resonance peaks. When the static magnetic field B0 deviates by a small angle from the magnetic field B1, each angle changes, the projection of the static magnetic field on each axis changes, and the positions of the corresponding 4 pairs of peaks also change accordingly.

  • In this article, we do not consider the spatial inhomogeneity of the static magnetic field, only discuss the impact of the spatial inhomogeneity of the microwave magnetic field on the system. The system parameters are as follows: longitudinal relaxation rate γ1 = 1000 s−1, transverse relaxation rate γ2 = 2.5 × 105 s−1, and pumping rate γp = 5 × 105 s−1. The magnetic field parameters: microwave magnetic field Bx = 330 μT and static magnetic field Bz = 2 mT. Noise module parameters: coupling strength b = 3.6 μs−1, correlation time τc = 25 μs.[15] Figure 8(a) shows the ensemble ODMR spectrum when the microwave magnetic field is perpendicular to the α axis and the static magnetic field is parallel to the α axis. As the microwave power increases, the broadening becomes larger, which obscures the information of hyperfine coupling. The 3 hyperfine peaks overlap into 1 peak, and the ensemble ODMR spectrum finally presents 2 pairs of resonance peaks.[22] Figure 8(b) shows the π-pulse width from the Rabi oscillation is 74 ns when the microwave amplitude Bx = 330 μT and the microwave frequency ωx = 2813 MHz.

  • Ideally, the microwave axial direction is perpendicular to the α-axis of the ensemble NV centers. In reality, the microwave axial direction has an inhomogeneous distribution in space. We assumed that the axial distribution range is θ, and the number of NV centers is equal per unit angle. In Fig. 6(b), the angle from the purple solid line to the purple dashed line indicates that the axial distribution range of microwaves is 30°. In the model, a group of 12 single NV center modules (to achieve hyperfine coupling effects and spatial orientations of different NV axes) is used to simulate a single microwave deviation angle. Then, the light intensity weighting coefficients module is employed to set N model groups to simulate the axial inhomogeneous distribution of the microwave. Considering both computational power and statistical representativeness, we conducted simulation studies with N = 4. For example, when θ = 30°, the axial deviation angles are 0°, 10°, 20°, and 30°. We discussed the cases at θ = 0°, 30°, 60°, and 90°, respectively. Table 2 recorded the output characteristics of the system at different θ.

    In a microwave magnetic field, only the component perpendicular to the NV axis can drive spin transitions. The spatial inhomogeneity of the microwave axial direction destroys the consistency of the effective coupling between microwaves and spins, reducing the effective coupling efficiency between microwaves and NV spins. We obtained broadening and contrast by fitting the simulated ODMR curves with a Lorentz function. Figure 9(a) shows that when the maximum deviation angle of axial inhomogeneity is 90°, the resonance peak broadening decreases by 1.4 MHz compared with no deviation, the contrast decreases by 27%, and the sensitivity decreases by 1.2 times according to formula (2). At the same time, inhomogeneity will destroy the phase consistency of Ramsey interference, leading to enhanced dephasing effect and reduced contrast. Figure 9(b) shows that when the maximum deviation angle is 90°, the dephasing time decreases from 427 ns to 254 ns, the Ramsey contrast decreases by 74.4%, and the sensitivity decreases by 5.1 times according to formula (2). The core mechanism of the Hahn echo lies in “π-pulse phase refocusing”. However, the axial inhomogeneity of the microwave field disrupts this process. The phases of some NV spins cannot be fully flipped by the π-pulse, preventing their subsequent phase refocusing. Ultimately, this leads to a decrease in the peak value of the overall echo signal and a reduction in contrast. Figure 9(c) shows that when the maximum deviation angle of the microwave axial direction is 90°, the transverse relaxation time decreases from 3370 ns to 2765 ns, the contrast of the Hahn echo signal decreases by 69%, and the sensitivity decreases by 3.6 times according to formula (2).

  • The microwave amplitude is inhomogeneously distributed in space, as shown in Fig. 10(a). The yellow block is a diamond containing NV centers, with a size of 5 mm×5 mm×0.5 mm. A microwave magnetic field is applied along the x-axis, and a single-loop antenna (SLA) is used to generate the microwave magnetic field.[23] Single NV centers are uniformly distributed within the ensemble NV centers bulk. It is assumed that the microwave amplitude on a small circular ring with a radius of r is equal, and there is a small circular ring area ds = π(r + dr)2 − πr2 ≈ 2πrdr. Then, the number of NV centers on the small circular ring satisfies Nr ∝ ds ∝ r, based on which the parameters of the light intensity weighting coefficients module can be set in the simulation model. Figure 10(b) The central position and the corresponding microwave amplitude are (0 mm,330 μT). The microwave magnetic field has a linear gradient distribution in space, where k is the slope of the linear distribution gradient.[23,24]

    By setting the microwave amplitude and light intensity weighting coefficients in the simulation model according to different radii, the spatial inhomogeneity of the microwave amplitude can be well simulated. Similarly, considering both computational power and statistical representativeness, we uniformly selected 4 groups of radii for simulation. The radii are 0.5 mm, 1 mm, 1.5 mm, and 2 mm, respectively, and the light intensity weighting coefficients ratios are 0.5:1:1.5:2. We discussed the cases of k = 0, 10, 20, 30, 40, and 50 μT/mm, respectively. Table 3 records the output characteristics of the system at different k.

    As the amplitude gradient increases, the frequency consistency of the ensemble NV centers spin transition is broken, resulting in the expansion of the spin resonance frequency distribution range, which is manifested as the inhomogeneity-induced broadening of ODMR. In Fig. 11(a), when k = 50 μT/mm, the linewidth increases by 1.7 MHz compared to the uniform distribution, and the sensitivity decreases by a factor of 1.1. The inhomogeneity of microwave amplitude leads to differences in the spin transition frequencies of different NV centers. After the free spin precession between the two π/2 pulses, phase dispersion occurs, which manifests as an enhancement of the system’s dephasing effect. In Fig. 11(b), when k = 50 μT/mm, the dephasing time decreases from 427 ns to 103 ns, the Ramsey contrast decreases by 60.3%, and the sensitivity decreases by a factor of 5.1. Microwave inhomogeneity will cause the pulses to be unable to fully compensate for the phase dispersion caused by the inhomogeneity of the static magnetic field. Pulse sequences such as Hahn echo fail to refocus, resulting in a decrease in echo signal intensity and degradation of coherence. In Fig. 11(c), when k = 50 μT/mm, the Hahn echo signal contrast decreases by 51.7%, and the sensitivity decreases by a factor of 1.8. In addition, spatial inhomogeneity will lead to complex decoherence dynamics in the system, which cannot be completely described by a single decay time constant. The stretched exponent α of the ensemble decay ranges from 0.5 to 3,[10] and the higher the spatial inhomogeneity of the microwave magnetic field, the larger fitted α.

4.   Conclusion
  • In this work, we designed a multi-module simulation program consisting of a single NV center simulation module and an ensemble control module. By constructing a cage-based diamond NV center experimental system, as well as the verification via ODMR, Ramsey, and Hahn echo experiments, the output curves by the simulation are highly consistent with the experimental data. The model also realizes the ensemble 8-peak ODMR spectrum and the hyperfine coupling effect.

    Based on this model, we studied the influence of the inhomogeneous spatial axial and amplitude distributions of the microwave magnetic field on the performance of the ensemble NV centers, respectively. When the axial inhomogeneity of the microwave magnetic field is the largest, the ODMR spectrum contrast decreases by 27%, and the sensitivity decreases by 1.2 times. The dephasing time decreases from 427 ns to 254 ns, the Ramsey contrast decreases by 74.4%, and the sensitivity decreases by 3.9 times. The Hahn echo signal contrast decreases by 69%, and the sensitivity decreases by 3.6 times. When the microwave magnetic field amplitude gradient is k = 50 μT/mm, the ODMR spectrum broadening is 1.7 MHz larger than that in the uniform distribution, and the sensitivity decreases by 1.1 times. The dephasing time decreases from 427 ns to 103 ns, the Ramsey contrast decreases by 60.3%, and the sensitivity decreases by 2.52 times. The Hahn echo signal contrast decreases by 51.7%, and the sensitivity decreases by 1.8 times. The model provides quantitative support for microwave parameter optimization, along with a basis for pulse sequence optimization and microwave field uniformity improvement. The modular design facilitates the subsequent inclusion of multi-physics coupling effects, further enhancing the predictive ability of the model. In the future, this model could be combined with artificial intelligence (AI) to develop new pulse sequences and achieve intelligent parameter regulation.

Appendix A: Theory
  • When conducting theoretical analysis of NV center quantum sensing, the Hamiltonian energy operator is usually used to analyze, study, and perform theoretical calculations of the quantum spin state. The intrinsic Hamiltonian of the NV center is[25,26]

    where ωD = 2π × 2.87 GHz is the zero-field splitting, γe = 28.03 GHz/T is the electron spin gyromagnetic ratio, ħ is the reduced Planck constant, ħ = h / 2π, h is the Planck constant, S is the spin operator, Sx, Sy, Sz are the projection components of S on each coordinate axis, and B is the external magnetic induction field. For a system with spin quantum number S = 1, Sx, Sy, Sz can be expressed as

    Substituting Eq. (A2) into Eq. (A1) gives

    where Bz is the static magnetic field, and Bx, By are microwave fields applied in different vertical directions. According to the standard Liouville equation of quantum statistical mechanics[27]

    where dρ∼/dt represents the rate of change of the density matrix with time, [H∼,ρ∼]/iħ represents the basic evolution process of the quantum system, (1//2){Γ^,ρ∼} represents the processes of decoherence and dissipation of the quantum state, and Λ represents the contribution of additional correction terms or other physical processes.

    Introduce the relaxation matrix Γ^[27,28]

    where γ1 represents the longitudinal relaxation rate, and Γp represents the transfer rate of non-polarized energy levels to polarized energy levels caused by optical pumping. Substituting the term (1/2){Γ^,ρ∼} into the Liouville equation (A4) gives

    where ρii is the probability that the quantum system is in the quantum state |i⟩ at a certain moment, and ρij characterizes the quantum coherence between different pure states in the quantum system.

    Considering that there are other factors affecting the transverse relaxation, after expressing the transverse relaxation with γ2 and γ3, it is

    Introduce the repopulation term Λ[27]

    Substituting Eqs. (A3), (A7), and (A8) into the Liouville equation (A4), and making the following substitutions according to the properties of the density matrix,[25] we have

    Finally, the dynamic equations for the evolution of the density matrix of the three-level model with all real terms can be obtained

    According to the characteristics of the density matrix, its diagonal elements ρ11, ρ00, ρ−1−1 are the probabilities, i.e., the populations, of the quantum system being in the |+1⟩, |0⟩, |−1⟩ states at a certain moment, and the trace of the matrix always satisfies ρ11 + ρ00 + ρ−1−1 = 1.

    Since the probability of radiative transition of electrons in the |0⟩ state after pumping is relatively high, while the probability of electrons in the |±1⟩ states returning to the ground state through intersystem crossing (ISC) after pumping is relatively high, it can be considered that the radiative fluorescence intensity is proportional to the population numbers ρ00, ρ11, ρ−1−1 of the three energy levels, but the proportionality coefficients are different, which are α, β, β respectively, and α > β. Therefore, the fluorescence intensity measured in the experiment can be expressed as[29]

    For the given set of equations for the density matrix evolution dynamics, to solve this ordinary differential equation, we consider using the RK4 algorithm[30]

    For Eq. (A12) multiple coupled equations, there are

    When solving the density matrix dynamics equation, the RK4 algorithm has high precision, high stability, and simplicity of implementation. It has significant advantages in balancing accuracy and computational cost and handling the evolution of complex quantum systems.

Figure (11)  Table (3) Reference (30)