2026 Volume 35 Issue 2
Article Contents

Wen-Ting Gan, Zi Li, Chen Wang, Xia Hua, Xin Tong. Steps towards a 229Th ionic nuclear clock in a linear ion trap[J]. Chinese Physics B, 2026, 35(2): 023703. doi: 10.1088/1674-1056/ae31db
Citation: Wen-Ting Gan, Zi Li, Chen Wang, Xia Hua, Xin Tong. Steps towards a 229Th ionic nuclear clock in a linear ion trap[J]. Chinese Physics B, 2026, 35(2): 023703. doi: 10.1088/1674-1056/ae31db

Steps towards a 229Th ionic nuclear clock in a linear ion trap

  • Received Date: 30/08/2025
    Accepted Date: 12/11/2025
    Available Online: 01/02/2026
通讯作者: 陈斌, bchen63@163.com
  • 1. 

    沈阳化工大学材料科学与工程学院 沈阳 110142

  1. 本站搜索
  2. 百度学术搜索
  3. 万方数据库搜索
  4. CNKI搜索

Figures(8)  /  Tables(6)

Article Metrics

Article views(312) PDF downloads(2) Cited by(0)

Access History

Steps towards a 229Th ionic nuclear clock in a linear ion trap

Abstract: Owing to the presence of a low-energy, long-lived nuclear isomeric state, 229Th is an ideal candidate for developing the next generation clock — the nuclear clock — holding great promise for both applied and fundamental physics. The 229Th ionic nuclear optical clock has garnered considerable attention, attributed to its high precision with a relative uncertainty of ≤ 1.5 × 10−1 and the potential for common-mode noise cancellation via self-comparison between the nuclear transition and the electronic transition of thorium ions. In this article, we focus on Thn+ ions (n = 1, 2, 3) and present a comprehensive review of the current progress in the development of ionic nuclear clocks, covering essential steps such as ion generation, trapping, and cooling. Furthermore, we discuss the realization of a closed-loop clock cycle, addressing key aspects including stable isomer excitation and efficient isomer deexcitation.

1.   Introduction
  • Today’s most precise time and frequency measurements are performed with optical atomic clocks, which play a pivotal role in various fields, such as the global navigation satellite systems,[1–3] the synchronous communication networks,[4] the time reference,[5,6] and the fundamental physics research.[7–9] However, a new type of clock, called a “nuclear clock”, is under development. It employs a nuclear transition instead of an atomic shell transition for precise time measurement.[10,11] With a first nuclear excitation state of only ∼ 8.4 eV and a radiative lifetime of ∼ 103 s,[12]229Th is the sole candidate for developing a nuclear clock among currently known nuclides.

    A nuclear clock based on the nuclear transition of 229Th is theoretically capable of achieving a systematic uncertainty of 1.5 × 10−1,[11] outperforming state-of-the-art atomic clocks, as shown in Table 1. First, the exceptionally low blackbody radiation (BBR) shift uncertainty in the 229Th nuclear clock arises from its nuclear transition between nuclear states with identical electronic configurations. This symmetry results in a differential polarizability Δαs of ∼10−5a03,[11] which is 7–8 orders of magnitude smaller than those of electronic transitions in 87Sr,[13]27Al+,[14] or 40Ca+[15] clocks. Therefore, the clock uncertainty from the BBR shift is 1.3 × 10−22 at room temperature,[11] surpassing the limits of present atomic clocks. Second, owing to the atomic nucleus being about five orders of magnitude smaller than the electron shell, its magnetic dipole moment is significantly smaller than that of electrons, making nuclear clocks less susceptible to magnetic field than atomic clocks. Consequently, the systematic uncertainties arising from the Zeeman effect are reduced by an order of magnitude compared to atomic clocks. Third, the Stark effect contributes minimally to the overall uncertainty of the nuclear clock, which is exceptionally low. This remarkable insensitivity originates from the extremely small differential nuclear polarizability (Δαnuc<10−14a03)[11] and the highly effective shielding of the nucleus from external electric fields by the surrounding electron cloud. For all these reasons, this new type of clock is being considered for applications such as searching for the temporal variations in the fine-structure constant,[16,17] detecting the dark matter,[18,19] serving as a gravitational wave detector,[7] and applying to the chronometric geodesy.[20]

    To develop a nuclear clock, the first step is to precisely measure the transition frequency from the ground state to the isomeric state. Since Kroger and Reich observed the existence of an extremely low-lying first excited state of 229Th nuclei in 1976,[21] extensive investigations into the energy of this isomeric state have been carried out via γ-ray spectroscopy,[22–28] internal conversion (IC) electron spectroscopy,[29] and direct vacuum ultraviolet (VUV) spectroscopy,[30,31] as shown in Fig. 1(a). With the successful preparation of 229Th-doped crystals and the development of VUV lasers, significant progress has been made in energy measurement as illustrated in Fig. 1(b). In 2024, a 229Th-doped CaF2 crystal grown at the Technische Universität Wien[32] was irradiated with a nanosecond-pulsed VUV laser generated at the Physikalisch-Technische Bundesanstalt (PTB) and the first resonant excitation was observed.[33] This result was soon independently verified using a 229Th-doped LiSrAlF6 crystal at the University of California-Los Angeles (UCLA).[34] Building on these experiments, researchers at the Joint Institute for Laboratory Astrophysics (JILA) used a VUV frequency comb to directly excite the narrow 229Th nuclear clock transition in a 229Th:CaF2 crystal, improving the measurement result to the kHz level.[35] Soon afterwards, JILA also first achieved nuclear excitation in 229ThF4 thin films on MgF2 and Al2O3 substrates, respectively.[36] Lately, Elwell et al. obtained the first laser-based conversion electron Mössbauer spectroscopy of 229Th in a thin sample of 229ThO2.[37] While the above measurements were conducted on Th4+ ions, theoretical calculations revealed a −639 MHz clock transition frequency shift between Th3+ and Th4+ ions due to electron-induced nuclear frequency shifts.[38]

    With the determination of nuclear transition frequency, various 229mTh-based nuclear clock concepts are discussed. Two primary ones are the ionic nuclear clock and the solid-state nuclear clock.[10,39] The ionic nuclear clock scheme is based on a single 229Th3+ ion or a Coulomb crystal of 229Th3+ ions. These ions can be stably trapped for extended periods in an ion trap, effectively isolating them from environmental perturbations and creating favorable conditions for time measurement. For the solid-state nuclear clock scheme, the approach utilizes VUV-transparent crystals doped with 229Th, aiming to directly excite the nuclear clock transition using a VUV laser. The solid-state path requires parallel advancements in generating a narrow-linewidth, high-intensity VUV laser for excitation, and in developing high-purity-doped crystals to amplify the signal for achieving a measurable signal-to-noise ratio.

    Detailed performance metrics of the ionic and solid-state nuclear clocks are summarized in Table 2. Among various nuclear clock concepts, the solid-state nuclear clock concept offers compelling advantages for practical applications. The internal conversion electron Mössbauer spectroscopy (CEMS) scheme in ThO2 enables an exceptionally short interrogation cycle due to its ∼ 10 μs isomer lifetime, theoretically boosting short-term stability by eight orders of magnitude compared to radiative approaches, leading to a projected clock instability of ∼ 2 × 10−1 at 1 s.[37] The large ensemble of nuclei (1015–1018 cm−3[32,34,40]) provides a signal enhancement over ionic systems. The maturity of the thin-film deposition techniques, as demonstrated with ThF4, facilitates the development of low-radioactivity, integrated devices, paving the way for portable, chip-scale nuclear clocks.[41] While the solid-state nuclear clocks offer superior short-term stability and integration potential, they still face greater challenges. For thorium-doped crystals, the nuclear transition in the solid-state environment is influenced by electronic charge density, electric field gradient, and field gradient asymmetry at the nucleus, all of which are temperature-dependent. To reach a precision of 10−18, a stable crystal temperature of 5 μK is required.[41] The internal-conversion-based ThO2 nuclear clock is even more limited, with its precision constrained to ∼ 7.9 × 10−1 due to the isomer lifetime broadening of 2π × 16 kHz.[37] By contrast, the single-ion nuclear clock demonstrates a clear advantage in systematic uncertainty, with a fractional inaccuracy projected to reach 1.5 × 10−19.[11] Additionally, comparing the nuclear transition and the electronic transition of thorium ion system offers an opportunity to measure temporal variations in the fine-structure constant within a single experimental setup, with common-mode rejection of certain systematic effects.[42] Calculations indicate that 229Th3+ shows promise as an ionic clock candidate, capable of achieving 10−18-level accuracy via the 5f 2F5/2 → 5f2F7/2 electronic transition. Based on this frequency accuracy of 229Th3+ ionic clock, measuring the frequency ratio between the nuclear and ionic clock could yield a precision of 10−21-yr−1 for the drift of the fine structure constant (α˙/α). Building on the above advantages of the ionic nuclear clock and our group’s established research in this field, this review focus on the current status and prospects of ionic nuclear clocks.

    The first detailed proposal for an ionic nuclear clock was presented by Peik and Tamm in 2003.[10] The trivalent (3+) state was chosen because it has a suitable electron energy level structure that allows for direct laser cooling. Apart from the 3+ state, the monovalent (1+) and divalent (2+) states have received widespread attention. Their abundant electron energy levels provide more possibilities for resonantly enhancing excitation via an electronic bridge process.[43–45] Other charged thorium ions, such as Th−,[46,47] Th4+,[48] Th6+,[49] and Th35+,[50] have also been investigated. In this paper, 229Thn+ ions (n = 1, 2, 3) are reviewed in terms of their generation, trapping, cooling, and the realization of the clock cycle.

2.   Generation of the thorium ions
  • Thorium is a refractory metal with a high melting point (2023 K), making it difficult to produce an atomic source of 229Th. Additionally, the ionization energies of Th, Th+, Th2+, and Th3+ range from several electronvolts to tens of electronvolts, as shown in Table 3. Therefore, producing thorium ions via photoionization is complex. Even for generating Th+ ions, three-photon resonance photoionization is required.[51] Furthermore, 229Th is an extremely rare radioactive isotope, with an estimated global stock of ∼ 40 g at reasonable isotopic purity.[36,52] Given these factors, laser ablation is a relatively suitable method for ion generation. From the perspective of 229Th acquisition, another feasible approach to obtain thorium ions from the α decay of 233U is employed in some research groups. Comparing these two methods, laser ablation is easy to operate but has a low ion yield, while α decay enables continuous ion generation yet requires complex purification. Alternative approaches, such as inductively coupled plasma techniques[53] and electron-beam evaporation,[54] are also under investigation.

  • Laser ablation uses a short pulse laser with sufficiently high energy density to irradiate the surface of solid targets, inducing rapid heating and phase transitions, thereby generating plasma. At low pulse laser intensities, neutral atoms are predominantly produced during the ablation process[55] and can be further photoionized within an ion trap.[56–59] When the laser pulse intensity is sufficiently high,[60] large numbers of charged ions and electrons are produced during the ablation process.[61–63] For thorium ion generation, when the laser intensity exceeds a threshold on the order of 108 W⋅cm−2, ions escape from the plume (an expanding plasma consisting of various neutral particles, electrons, and ions with diverse charge-to-mass ratios and energy distributions)[64] and move away from the target surface at velocities in the range of 104 m⋅s−1.[65] Additionally, it has been observed that at shorter wavelengths, the transition from thermal ablation to phase explosion occurs at lower laser photon fluences, indicating that the ablation threshold decreases with decreasing laser wavelength.[66–68] To avoid perturbing the electric potential of the ion trap, the ablation target is typically positioned outside the trap.

    A 232Th metal target is placed ∼ 55 mm away from the entrance endcap along the trap axis, as shown in Fig. 2(a). A diode-pumped pulsed laser at 1064 nm wavelength is used for ablation, with a pulse duration of 8 ns and a pulse energy of 450(30) μJ. It is focused to an 80(10) μm spot size on the target at an incident angle of ∼ 30°, resulting in a laser intensity of 2.80(72) × 108 W⋅cm−2. Under these conditions, Th+, Th2+, and Th3+ ions are generated.[69] A 3D Monte Carlo simulation of the dynamic process was performed using SIMION to investigate the velocity distributions of ablated thorium ions.[70] The simulation indicates that the velocity distributions of ablated ions can be described by the shifted Maxwell–Boltzmann–Coulomb (MBC) distribution function[71]

    where A is a normalization constant, kT is the ion distribution temperature, m and v are the ion mass and velocity, vk=γkT/m is the center-of-mass velocity (γ = 5/3 for monatomic metal samples), and vc is the Coulomb velocity depending on the magnitude of the effective electric field generated by the plasma. The MBC velocity distributions of various ablated charged thorium ions are illustrated in Fig. 2(b). As the ion charge state increases, the most probable velocity of the ions increases while the proportion of ions decreases. According to the mass spectrum signal shown in Fig. 5(b), the ratio of Th3+ ions to Th+ ions is 18%, and the ratio of Th2+ ions to Th+ ions is 50%. This indicates a lower yield of higher-charge-state ions, as generating such ions involves a smaller ionization cross section and requires higher energy.

    Such an ablation method has also been successfully implemented at the Georgia Institute of Technology,[72,73] PTB,[65,74–78] Moscow Engineering Physics Institute (MePhI),[53,79,80] and Griffith University.[81] The detailed parameters are summarized in Table 4. Furthermore, laser ablation can also be combined with photoionization[76,77] or electron impact ionization[82] to generate thorium ions.

  • The 229Th has no natural abundance but can be artificially produced through the decay of parent nuclides. As illustrated in Fig. 3(a), 229Th is populated via three natural decay paths: electron capture decay of 229Pa, β− decay of 229Ac, and α decay of 233U.[83] For the first pathway, 229Pa absorbs an electron and converts a proton to a neutron, thus generating 229Th with a characteristic half-life of 1.5 days. The major challenge in obtaining 229Th via this decay channel lies in the inherently low production yield of the parent nuclide 229Pa itself. As an alternative, 229Ac undergoes β− decay to produce 229Th rapidly, with a half-life of 62.7 min. However, 229Ac currently requires production in an online facility, such as the ISOLDE facility at CERN.[84] Regarding the α decay of 233U, this radioactive decay has a half-life of ∼ 159200 years. The parent nuclide 233U can be sustainably and stably produced in Th–U molten salt reactors (MSRs).[85] Beyond nuclear decay pathways, 229Th can be produced via the neutron transmutation of 226Ra, 228Ra, 227Ac and 228Th in reactor-based production.[86,87] Additionally, an alternative approach for 229Th production has been proposed, which involves bombarding a polyethylene (CH2) target with accelerated 232Th ions to induce the neutron-knockout reaction (232Th→229Th + 3n).[88]

    Among these approaches, the α decay of 233U currently represents the only means to obtain usable quantities of 229Th. The decay chain of 233U proceeds through sequential α and β− decays, as illustrated in Fig. 3(b), ultimately yielding stable 209Bi as the end product. According to the half-life of 233U, its decay constant is determined to be 1.38 × 10−1 s−1. Consequently, it can be calculated that 1000 Bq of 233U corresponds to 7.25 × 1015 atoms, with a mass of approximately 2.8 μg. For 229Th with the same activity level, the corresponding number of atoms and mass are 3.59 × 1014 and 0.137 μg, respectively. The extraction of 229Th from the α decay of a 233U source can continuously produce 229Th ions of varying charge states, with approximately 2% of them populating the isomeric state.[89,90] In 2015, Wense et al. quantitatively determined the activities of 233U and its decay daughters using γ-ray energy and α-energy spectra, and evaluated the emission efficiency of α-recoil particles through recoil ion implantation experiments.[91]

    The 229Th α-recoil ions leave the source material with a kinetic recoil energy of 84.3 keV, necessitating a high-density buffer-gas environment and thus a complex differential pumping setup. To date, Ludwig–Maximilians–Universität (LMU),[77,91–96] PTB,[97,98] and Rikagaku Kenkyusho (RIKEN)[12] have constructed dedicated setups for thorium ion extraction from the α decay of 233U sources and successfully obtained 229Th ions. The experimental setup at LMU[92] is shown in Fig. 4. The 233U source is mounted in front of a radio-frequency (RF) and direct-current (DC) funnel placed within a buffer-gas stopping cell. 229Th ions, along with other daughter products of the 233U decay chain, are first decelerated in the buffer-gas stopping cell filled with 40 mbar of ultra-pure He 6.0 and then guided by the RF + DC funnel system (comprising 50 ring electrodes) towards a Laval extraction nozzle. Upon passing through the nozzle, the extracted ions are accumulated in a radio-frequency quadrupole (RFQ). Subsequently, a quadrupole mass filter (QMF) is used to select target thorium ions, filtering out thorium ions in other charge states, other decay products, and molecular ions formed via reactions with impurities in the buffer gas. After mass purification of the ion beam, the ions are transported to an ion trap with low kinetic energy. The extraction efficiencies of Th3+, Th2+, and Th+ ions are 10%, 5.5% and 0.3%, respectively.[91] At PTB,[97] the thorium ion beam is subsequently bent by 90° via an electrostatic deflector to provide unobstructed laser access along the trap axis. An RF electric octupole guide is used to transport the ions from the deflector to the ion trap. In contrast to the setups at LMU and PTB, the extraction process at RIKEN[12] is achieved using an RF carpet located in a vacuum chamber, which is filled with helium buffer gas (20 mbar). The extracted ions are then directly transported to a linear ion trap. The trap chamber is filled with helium buffer gas at a pressure of 2 × 10−1 mbar, eliminating the need for multistage differential pumping.

3.   Trapping of thorium ions in ion traps
  • Since thorium ions produced by laser ablation or α decay of 233U have relatively high velocities, they typically require deceleration and transport from external regions into the trap center for long-term stable confinement, which facilitates the subsequent manipulation for realizing the ionic nuclear optical clock. Trapping of 229Th ions has been achieved at the Georgia Institute of Technology,[73] PTB,[76,77,98] LMU,[77,91] and RIKEN.[12] Additionally, several experiments have reported the successful trapping of 232Th ions.[65,69,72,74,75,78–81]

  • Ions are commonly loaded into the trap via two approaches: axial injection (along the trap axis) or radial injection (perpendicular to the trap axis). For ablated ions, radial ablation loading exploits co-generated ions and electrons to momentarily neutralize the RF voltage on the trap electrodes, enabling rapid suppression of the confinement barrier within 1 μs.[65] Following ion injection, the RF trapping potential is swiftly restored on a comparable timescale of μs, thereby achieving ion loading. The axial confinement of the ion trap employs a static electric field, which provides superior control precision compared to the RF electric field. Furthermore, axial ablation loading demonstrates an enhanced capacity to trap ions with broader kinetic energy distributions when the distance between the trap center and endcap electrodes increases.[69,99] Currently, following laser ablation, successful ion loading along the radial direction is limited to Th+ and Th2+ ions,[65] while axial loading accommodates Th+, Th2+, and Th3+ ions.[69,79] For thorium ions generated via the α decay of 233U, they are typically injected into the trap along the axial direction after collisional deceleration with buffer gas.[95,97,98]

    Compared with passive loading, in which the endcaps remain fixed, the loading efficiency can be dramatically improved via dynamic temporal control of the axial trapping potentials.[100] In order to dynamically load thorium ions from the axial direction, when the ablation laser fires, the voltage on the entrance endcap is switched off within 1 μs and held at 0 V for a period, as shown in the upper panel of Fig. 5(a). Once the ions reach the center of the ion trap, the voltage at the entrance endcap is quickly switched back within 1 μs to realize axial confinement, as depicted in the lower panel of Fig. 5(a). This dynamic laser ablation loading method allows the trapping of not only slow, singly charged ions but also fast, multiply charged ions.

    The dynamic ion loading method offers greater controllability compared to directly loading laser ablation-generated ions into an ion trap. In addition to the ion trap’s RF voltage, endcap voltage, and buffer gas partial pressure, dynamic loading can also control the number and velocity distribution of loaded ions via the trap’s endcap turn-on time.[99] Figure 5(b) illustrates the variation in signal intensity of trapped thorium ions with different charge states as a function of the turn-on time of the entrance endcap, which ranges from 10 μs to 55 μs. Th3+, Th2+, and Th+ ions achieve optimal loading at 15 μs, 20 μs, and 35 μs, respectively, which correlates with their velocity distributions. Additionally, the total lifetime of trapped 232Th3+ ions has been measured. In Fig. 6, the black dots show that the fitted total lifetime of Th3+ ions in the presence of helium buffer gas is 24(3) s.[69] By further optimizing the RF trapping potential to mitigate RF heating effects and purifying the helium buffer gas, the total lifetime of Th3+ ions is significantly extended to 493(32) s, as indicated by the red dots. Under these conditions, laser cooling of Th3+ ions becomes experimentally feasible. Replacing the current ion trap with a cryogenic ion trap will significantly extend ion lifetimes, owing to improved vacuum conditions and effective suppression of electromagnetic interference.[95,96,101]

  • Due to the short lifetime of trapped thorium ions and the difficulty of fluorescence detection, existing methods for the initial demonstration of trapped thorium ions primarily rely on mass spectrometry techniques, including quadrupole mass spectrometry (QMS)[92,102,103] and time-of-flight (TOF) mass spectrometry.[65,69,82,104]

    As illustrated in Fig. 7(a), the integration of a linear ion trap with a time-of-flight mass spectrometer (LIT TOF-MS) comprises an ion trap, electrostatic lenses, deflection electrodes, and a channel electron multiplier (CEM) detector. Similar to the Wiley–McLaren configuration, the two trap rods farther from the grounded plate serve as repelling rods with a higher positive potential (≈ 1000 V), while the two closer ones act as extracting rods with a lower positive potential (≈ 800 V). Together with the grounded plate, they form a three-stage Wiley–McLaren-type TOF mass spectrometer. Upon exiting the grounded plate, ions enter a field-free drift region where transverse divergence occurs perpendicular to their propagation axis. Two Einzel lenses are used to focus and collimate the ion beam into a compact profile. Additionally, two orthogonally aligned pairs of parallel deflection plates are mounted between the lenses to control the ion beam vertically and horizontally. The focused and deflected ion beam ultimately reaches the CEM detector, where the ion signal is detected.

    Ablated thorium ions with different charge states exhibit different velocity distributions, as discussed in Subsection 2.1, and arrive at the trap center with different flight times. A typical mass spectrum of thorium ions at the turn-on time of 15 μs is shown in Fig. 7(b). The full width at half maximum (FWHM) values for Th3+, Th2+, and Th+ ions at a turn-on time of 15 μs are 64 ns, 59 ns, and 87 ns, corresponding to mass resolutions of 61, 84, and 80, respectively, for thorium ions mass spectrometry at 300 K. These data (red dot) are presented in Fig. 7(c). Zimmermann et al. (blue triangle) employed TOF mass spectrometry to measure the ion yield and the distribution across the charge states of laser-ablated thorium ions. Due to limitations of laser energy density, only mass resolutions of 13 and 10 were obtained for Th2+ and Th+ ions, respectively.[65] Borisyuk et al. (green square) used a multi-sectional quadrupole linear Paul trap with an energy analyzer along the trap axis to measure energy distributions, with mass resolutions of Th3+, Th2+, and Th+ ions being 7, 21, and 34, respectively.[79]

    Apart from the above works, Churchill et al. modified the ion trap by integrating a CEM detector positioned off-axis at one end of the trap for mass spectrometry of thorium ions.[102] Building upon this foundation, Campbell et al. constructed a segmented hyperbolic ion trap with high-quality quadrupole potential control, enabling the confinement and mass spectrometric detection of trapped thorium ions.[103] Notably, Groot-Berning et al. implemented a dual detection scheme that combines non-destructive identification of trapped thorium ions via Ca+ Coulomb crystal fluorescence with destructive TOF analysis, achieving a TOF detection efficiency > 95% and a mass resolution of m/Δm ≈ 500 for Th+.[82] Telnov et al. developed a multi-segment quadrupole ion trap equipped with a secondary electron multiplier (SEM) for thorium ion detection, with TOF mass spectrometry calibrated using 88Sr+ ions.[104]

4.   Cooling of thorium ions
  • In ion trap experiments, effective cooling of trapped ions enables more stable ion confinement and suppresses Doppler broadening, thereby enhancing measurement precision. Common methods for ion cooling include buffer gas cooling,[105] resistive cooling,[106] direct laser cooling,[107] sympathetic cooling,[108] sideband cooling,[109] and so on. Typically, collisions with buffer gas are used to decelerate thorium ions, ensuring their effective loading. Once the ions are trapped in the ion trap, sympathetic cooling can be employed to further reduce their kinetic energy, enabling long-term stable confinement for subsequent operations. In particular, for Th3+ ions, direct laser cooling can also be utilized to achieve ion cooling.

  • Buffer gas cooling is a widely employed technique for cooling atoms, molecules, or ions to cryogenic temperatures.[110–113] It is achieved via collisional energy transfer between target particles and buffer gas particles in a vacuum chamber. The cooling efficiency depends critically on the temperature of buffer gas and the mass ratio of the buffer gas to the target particles, with optimal cooling achieved when Tgas is low and the mass ratio mgas/mtarget is much less than 1.[114] Owing to its low atomic mass (4 amu) and high ionization threshold (∼ 24.6 eV), helium is usually the preferred buffer gas.

    As discussed in Subsection 2.1, the velocity of thorium ion produced by laser ablation is on the order of 103 m⋅s−1, corresponding to an ion temperature in the range of 104–105 K. Such high kinetic energy hinders stable confinement within the trapping potential, causing ions to escape from the ion trap. Thus, buffer gas cooling is routinely employed to cool these ions experimentally. Typical buffer gas partial pressures range from 10−7 mbar to 10−5 mbar,[69,72,73] while pressures on the order of 10−3 mbar are occasionally employed for cooling ions to room temperature and depopulating metastable states by collisional quenching.[65,77] Furthermore, when buffer gases are employed to exert a drag force on ions, partial pressures around 10−2 mbar are used.[80] Similarly, thorium ions produced via the α decay channel of 233U decay carry a recoil energy of 84.3 keV, requiring higher buffer gas pressures for effectively decelerating ions, typically on the order of tens of mbar.[12,91,97]

  • Laser cooling plays a significant role in modern physics, having advanced the fields of atomic physics,[115] quantum science,[116,117] and precision measurements.[13,118,119] Typically, a cycling transition, in which the ion can continuously absorb and emit photons, is preferred. Among all thorium charge states, the Th3+ ion, characterized by a Fr-like electronic configuration with a closed inner shell and one valence electron, is currently the only one that can be directly laser-cooled.

    The energy level diagram of the 229Th3+ ion is given in Fig. 8(a), including the nuclear levels for the clock transition as well as the electronic levels for direct laser cooling. The laser cooling process is divided into two steps. In the first step, the two-level transition from 5f 2F5/2 state to 6d 2D3/2 state (green arrow) is used for laser cooling, at a laser wavelength of 1088 nm. In the second step, further cooling is achieved using a Λ-type three-level system formed by the 5f 2F5/2, 6d 2D5/2 and 5f 2F7/2 states, requiring wavelengths of 690 nm (pink arrow) and 984 nm (orange arrow).

    Due to its lack of hyperfine structure, lower radioactivity, and good material availability, the 232Th3+ ion was chosen for the initial feasibility demonstration. Direct laser cooling of 232Th3+ was experimentally achieved in 2009.[72] Subsequently, 229Th3+ ion was also successfully laser cooled in 2011 and the isotope shifts of several electronic transitions between 229Th3+ and 232Th3+ were estimated,[73] as shown in the second column of Table 5. Additionally, the isomer shift of the 5F5/2 ↔ 6D3/2 transition (1088 nm) was measured by Yamaguchi et al.,[12] as illustrated in the third column of Table 5.

    For the 229Th3+ ion, the nuclear ground state has a nuclear spin of 5/2 and the nuclear isomeric state has a nuclear spin of 3/2, resulting in the hyperfine level splitting. The corresponding hyperfine energy splittings are also illustrated in Fig. 8(a). The energy shifts arising from the hyperfine structure in 229Th3+ are on the order of GHz. These shifts can be addressed using electro-optic modulators (EOMs), thus achieving laser pumping of the hyperfine structure. An image of 229Th3+–232Th3+ bi-component Coulomb crystal is shown in Fig. 8(b).[73] The top image was taken with both 229Th3+ and 232Th3+ 690 nm fields present. The 232Th3+ and 229Th3+ 690 nm fields were then removed for the middle and bottom images, respectively. The larger mass-to-charge ratio of 232Th3+ causes it to radially accumulate in the outer shells of the crystal.

  • For atomic or molecular ions that cannot be directly laser-cooled, sympathetic cooling presents an essential methodology to reach ultracold regimes. This technique is achieved by co-confining laser-cooled ions and target ions within the same ion trap, where target ions are cooled via energy transfer to the laser-cooled ions through Coulomb interactions. The minimum temperature achievable through sympathetic cooling is constrained by the cooling limit of the laser-cooled ions and the interaction strength between the two ion species.

    In bi-component Coulomb crystals, ions with different mass-to-charge ratios exhibit radial separation. The radius of the ionic motion region and the ion’s mass-to-charge ratio satisfy the formula r1/r2=M1/Q1/M2/Q2,[120] where r1 and r2 are the radii of the motion regions of the ions with the mass-to-charge ratio M1/Q1 and M2/Q2, respectively. Therefore, ions with higher mass-to-charge ratios experience weaker radial confinement forces, positioning them in the outer regions of the crystal, while those with lower mass-to-charge ratios are more strongly confined and localized near the central regions. When ions have closely matched mass-to-charge ratios, their close spatial proximity enhances Coulomb interactions, leading to improved sympathetic cooling efficiency through stronger coupling of collective motions.

    To effectively sympathetically cool thorium ions, the mass-to-charge ratio of the laser-cooled ions should be close to that of the target thorium ions. In 2019, Groot-Berning et al. successfully loaded and trapped a 232Th+ ion in a linear Paul trap, which was embedded in and sympathetically cooled by small crystals of trapped 40Ca+ ions.[82] PTB demonstrated the first realization of sympathetic cooling between 230Th3+ and 88Sr+ ions, achieving the formation of a two-component Coulomb crystal.[97] Building on this foundation, the hyperfine structure of 229Th3+ ions in the nuclear ground state has recently been investigated via laser spectroscopy of trapped 229Th3+ ions that are sympathetically cooled by laser-cooled 88Sr+ ions in a linear Paul trap.[98]

    In our laboratory, 88Sr+ and 232Th3+ ions generated via laser ablation of a mixed target are loaded into a linear ion trap. Laser-cooled 88Sr+ ions produce bright fluorescence, forming a multi-component Coulomb crystal with dark 232Th3+ ions. Ejecting the crystal yields a TOF mass spectrum with distinct peaks corresponding to 88Sr+, 88SrO+, and 232Th3+ ions, confirming the successful sympathetic cooling of 232Th3+ ions by the co-trapped 88Sr+ ions.[121]

5.   Realization of a closed-loop clock cycle in thorium nuclear optical clock
  • In contrast to conventional atomic clocks, where closed-loop clock cycles rely on electronic transitions with accessible excitation pathways and fast spontaneous decay, the realization of a closed-loop cycle in the 229Th nuclear optical clock faces unique and formidable challenges. The nuclear transition in 229Th involves an extremely narrow linewidth and a radiative lifetime of ∼ 103 s,[12] posing significant obstacles to both efficient excitation and fast deexcitation. This section summarizes current strategies for nuclear excitation and recent advances in nuclear isomer quenching.

  • Since the second nuclear excited state has an energy of 28.4 keV, which is significantly higher than that of the first excited state, the nucleus can be approximated as a closed two-level system consisting of the nuclear ground state |g〉 and the first nuclear excited state |e〉 for theoretical calculations of the direct nuclear transition probability in 229Th. The time-dependent nuclear excitation probability ρexc(t) for a single nucleus under resonant irradiation is given by Torrey’s solution to the optical Bloch equations.[122] The Rabi frequency between the isomeric state and the nuclear ground state is

    Here, I represents the intensity of the excitation laser, wnuc is the angular frequency of the nuclear transition, ℏ denotes the reduced Planck constant, c is the velocity of light and Γ corresponds to the linewidth of the isomeric state. The Clebsch–Gordan coefficient for the sub-state transition between the isomeric state and the nuclear ground state Ceg is 1.[123] Based on the above calculation, Li et al. considered the relationship between the laser linewidth ΓL and the Doppler broadening linewidth ΓD and obtained the modified Rabi frequency.[124]

    So far, VUV pulse lasers generated via four-wave mixing (FWM)[33,34,36,125–127] and VUV frequency comb[35,41] have been used to irradiate different 229Th-doped crystals, achieving direct nuclear excitation of 229Th. Most recently, continuous wave (CW) VUV laser sources at 148 nm have also been demonstrated, which are obtained via two distinct approaches: second-harmonic generation (SHG) in a randomly quasi-phase matched SrB4O7 crystal[128] and FWM in cadmium vapor.[129] The detailed parameters are listed in Table 6. A power spectral density on the order of femtowatts per hertz (fW⋅Hz−1) is sufficient to successfully excite 229Th in 229Th-doped crystals from its nuclear ground state to the nuclear isomeric state. However, the particle density in Coulomb crystals (∼ 108 cm−3[130,131]) is seven to ten orders of magnitude lower than that in thorium-doped crystals (1015–1018 cm−3[32,34,40]), resulting in a corresponding reduction in signal intensity. Therefore, to achieve direct nuclear excitation in ion systems, the development of high-power, narrow-linewidth CW VUV laser sources is still necessary. Notably, the power spectral density of the latest VUV CW laser can reach nanowatts per hertz (nW⋅Hz−1), which is approximately 4 to 6 orders of magnitude higher than that of previous work, making the direct nuclear excitation of ion systems feasible.

    Beyond direct nuclear excitation, alternative excitation channels are under investigation, among which electronic bridge (EB) excitation has attracted significant attention. The EB excitation can be effectively treated as a process where an electron, when absorbing the energy of single photon, undergoes a transition from an initial state to a virtual intermediate state and then to a final state. At the same time, the nucleus is excited to the isomeric state from its ground state. Importantly, the resonance condition must be fulfilled. The energy difference between the virtual intermediate state and the final electronic state has to match the nuclear transition energy. The EB process of thorium ions with different charge states is discussed, including Th+,[43,44] Th3+,[133–135] Th4+,[48] Th6+,[49] and Th35+[50] ions. In 2024, Wang et al. accounted for both hyperfine structure and atomic decay of electronically excited ions, and their calculation results demonstrated that a remarkable 99.7% isomeric population transfer was theoretically reached via the stimulated Raman adiabatic passage method, presenting a potential nuclear-laser scheme based on the EB mechanism.[136] Beyond direct nuclear excitation and EB excitation, other isomeric excitation schemes are under discussion, including nuclear excitation by electron capture (NEEC) in plasma[137,138] or at heavy ion storage rings,[88,139] and the nuclear excitation via laser-driven electron recollision.[140,141]

  • 229mTh decays to the nuclear ground state through both magnetic dipole (M1) and electric quadrupole (E2) transitions, with the M1 transition being dominant. According to the latest experimental results, the radiative lifetime of the isomer state is ∼ 103 s.[12] This relatively long lifetime results in an extremely slow relaxation process, making it difficult to maintain the stable and continuous oscillation required for the clock, thereby limiting the clock’s performance and practical application prospects. Therefore, there is an urgent demand to explore new quenching channels to significantly accelerate isomer deexcitation.

    One approach is to exploit the interaction between the 229Th nucleus and its surrounding environment in 229Th-doped crystals. Embedding 229Th ions in specific host crystals may induce changes in nuclear decay properties through crystal electric field effects, potentially accelerating the decay process. A new competing electric-dipole (E1) channel for nuclear decay in a solid-state environment has been identified in Ref. [34]. Furthermore, the induced quenching of the nuclear isomeric state has been experimentally observed in 229Th-doped crystals. In 2024, the isomer half-life was significantly reduced under x-ray beam irradiation, suggesting the existence of additional decay paths.[31] Subsequently, laser induced quenching was observed independently by Schaden et al.[142] and Terhune et al.[143] The underlying physical process remains unclear and has become a focus of further investigation. Possible candidate mechanisms include couplings to electronic near-bandgap or defect states, EB processes in the electron cascades following X-ray-induced core-electron ionization,[31] or an IC decay process either by resonantly exciting defect-state electrons to the conduction band[143] or by resonantly transferring the wnuc ≈ 8.4 eV energy to a particle–hole electronic excitation.[144] Recent research has demonstrated that the excited nucleus in a thin ThO2 sample can decay rapidly by internal conversion. This process reduces the isomeric state lifetime to only ∼ 10 μs, allowing ∼ 108 relative reduction in clock interrogation time. A conversion-electron-based nuclear clock could lead to a ∼104 improvement in clock instability.[37]

    All reported advances in nuclear isomer quenching have been achieved in 229Th-doped crystal systems. For ion trap systems, realizing rapid nuclear isomer quenching mainly relies on the potential of non-radiative channels, such as IC and EB processes. If these non-radiative channels can be enhanced, they might provide alternative pathways for the isomeric state to decay efficiently. Therefore, exploring enhanced IC or EB channels in thorium ions of various charge states will be a key focus.

6.   Conclusion
  • Since the inference of a low-energy nuclear state in 229Th from the α decay of 233U in 1976, this isotope has continued to attract significant research attention. Over the past decades, substantial progress has been made, including advancements toward the realization of the nuclear optical clock. These advancements include, but are not limited to: the proposals of practical 229Th-based nuclear clock schemes, precise determination of the isomeric state energy, direct laser cooling or sympathetic cooling of Th3+ ions in Paul traps, measurements of nuclear properties such as magnetic dipole and electric quadrupole moments, and the successful demonstration of direct nuclear excitation.

    In this article, we have outlined the essential steps toward realizing an ionic nuclear clock based on 229Th ions confined in a linear ion trap. Starting from the generation of thorium ions via laser ablation and α decay of 233U, to the successful trapping and mass-resolved identification of various charge states, a feasible path for preparing suitable ion samples has been established. Cooling methods including buffer gas cooling, direct laser cooling, and sympathetic cooling have been discussed, each playing a critical role in reducing the motional energy of ions and enabling precision spectroscopy. Furthermore, the core challenge in realizing the 229Th nuclear optical clock — establishing an efficient closed-loop clock cycle — has been summarized and analyzed. Despite recent experimental and theoretical progress, particularly in crystal systems, many open questions remain for ion-trap platforms, especially regarding efficient excitation under low-density conditions and rapid quenching of the long-lived isomeric state.

    Advancing control over nuclear-electronic coupling, improving VUV laser technologies, and exploring enhanced non-radiative decay mechanisms of the nuclear isomeric state will be pivotal for the development of the 229Th ionic nuclear optical clock with unprecedented stability and accuracy, which holds great promise not only for timekeeping, but also for fundamental physics research. The ultimate realization of the 229Th nuclear clock will represent a transformative advancement in optical clock technology by shifting the fundamental reference from electronic to nuclear transitions. It will further open new avenues for probing fundamental physics, allowing ultra-precise investigations of physical constants, searches for temporal variations in the fine-structure constant, and rigorous tests of physics beyond the Standard Model. Such developments are poised to provide unprecedented insights into the fundamental principles that govern our universe.[145] Moreover, coherent control over the nuclear ground state and nuclear isomeric state of 229Th could potentially enable a novel qubit system. This would expand the range of existing qubit carriers beyond ions, which is of great significance for quantum computing and quantum information.[146]

Figure (8)  Table (6) Reference (146)

Catalog

    /

    DownLoad:  Full-Size Img  PowerPoint
    Return
    Return