2026 Volume 35 Issue 7
Article Contents

Zi-Qiang Yin, Zhi-Hao Liu, Jian Tang, Hui Jing, Xun-Wei Xu. Sensitive sensing based on quantum correlation of photons in weak nonlinear regime[J]. Chinese Physics B, 2026, 35(7): 074201. doi: 10.1088/1674-1056/ae5c71
Citation: Zi-Qiang Yin, Zhi-Hao Liu, Jian Tang, Hui Jing, Xun-Wei Xu. Sensitive sensing based on quantum correlation of photons in weak nonlinear regime[J]. Chinese Physics B, 2026, 35(7): 074201. doi: 10.1088/1674-1056/ae5c71

Sensitive sensing based on quantum correlation of photons in weak nonlinear regime

  • Received Date: 18/12/2025
    Accepted Date: 25/02/2026
    Available Online: 01/07/2026
通讯作者: 陈斌, bchen63@163.com
  • 1. 

    沈阳化工大学材料科学与工程学院 沈阳 110142

  1. 本站搜索
  2. 百度学术搜索
  3. 万方数据库搜索
  4. CNKI搜索

Figures(5)

Article Metrics

Article views(154) PDF downloads(0) Cited by(0)

Access History

Sensitive sensing based on quantum correlation of photons in weak nonlinear regime

Abstract: Quantum correlation of photons based on quantum interference, such as unconventional photon blockade (UPB), has been extensively studied for realizing single-photon sources in a weak nonlinear regime. However, how to use this effect for other practical applications is rarely studied. Here, we propose to realize angular velocity and temperature sensing based on the quantum correlation of photons induced by quantum interference. We demonstrate that UPB can be observed in the mixing field output from a Mach–Zehnder interferometer (MZI) with two cavities in its two arms based on quantum interference. We show that the second-order correlation function of the output field is sensitive to the parameters of the system, and propose schemes to realize angular velocity and temperature sensing by measuring the second-order correlation of the photons output from the MZI. We find that the second-order correlation function of the output field is much more sensitive to the parameters of the system than the mean photon number, which provides an application scenario for UPB in sensitive sensing.

1.   Introduction
  • Quantum correlation of photons can be described by correlation functions,[1,2] which provide a quantitative measure to characterize the quantum nature of light. To date, the application of quantum photon correlation has expanded from characterizing single photons[3,4] to demonstrating photonic quantum logic gates[5,6] and fractional quantum Hall states.[7]

    The quantum correlation of photons can be manipulated when they pass through an optical system containing strong photon–photon interaction. If the probabilities of multiphoton states are suppressed by the nonlinear interaction, then the output field becomes sub-Poissonian, which is referred to as conventional photon blockade (CPB).[8] CPB has been proposed in various optical platforms,[9–20] and has been observed in resonators strongly coupled to quantum emitters.[21–27]

    In the past decade, some novel mechanisms have been proposed to manipulate the correlation properties of photons under weak nonlinear interactions.[28–40] The one that attracts the most attention is the unconventional photon blockade (UPB),[41,42] where the probabilities of two-photon excitation are suppressed by destructive interference between different transition paths. UPB has been extensively studied in various systems, such as coupled optomechanical systems,[43–45] coupled cavities with second- or third-order nonlinearities,[46–60] a cavity embedded with a two-level atom,[61–66] coupled-resonator chains,[67–69] etc. UPB has been experimentally realized with a quantum dot in a semiconductor cavity quantum electrodynamics system[70] and with a SQUID in superconducting resonators.[71]

    In recent work, we found that the photon correlation of the mixing fields output from a Mach–Zehnder interferometer (MZI), with two cavities in the two arms, can be manipulated by quantum interference.[72] We uncover a scaling enhancement of photon blockade in the mixing fields output from the MZI. However, whether strong quantum correlation in the mixing output fields can also be realized in the weak nonlinear regime is still an open question. Moreover, we know that the MZI[73] is a good platform for the measurement of the relative phase acquired by the beam along the two paths, which offers applications in versatile sensing based on the interference pattern.[74–76] How to use the quantum correlation in the mixing fields output from the MZI for sensing is another interesting question.

    In this paper, we propose to realize sensitive sensing based on the second-order correlation of mixing fields output from an MZI, with two cavities in the two arms based on weak nonlinearity. We find that strong photon blockade can be realized in the weak nonlinear regime by the quantum interference between different paths for two-photon states passing through the MZI. We also show that the second-order correlation of the photons output from the MZI is sensitive to the system parameters, which is the main mechanism for sensing based on quantum correlation.

    We note that the angular velocities[77–89] and the temperatures[90–98] are usually measured by monitoring the frequency shift of the system under test. In addition, the Raman-ratio technique based on Stokes/anti-Stokes asymmetry is used to measure temperatures close to absolute zero in the field of cavity optomechanics.[99–104] In contrast, we propose schemes to realize angular velocity sensing and temperature sensing by measuring the second-order correlation of the photons output from the MZI. One of the noteworthy advantages of the sensing scheme based on the second-order correlation is that it can work with a very weak driving field, even at the single-photon level. Moreover, we show that the second-order correlation is much more sensitive to the parameters of the system than the mean photon number, so that the sensing schemes by detecting the second-order correlation may achieve a higher sensitivity than the schemes by measuring the mean photon number.

    The remainder of the paper is organized as follows. In Section 2, we present the model of a MZI with two cavities in the two arms. We show UPB in the output field of the MZI both numerically and analytically in Section 3. We demonstrate how to realize versatile sensing by measuring the second-order correlation of the photons output from the MZI in Section 4. Finally, we summarize our main results in Section 5.

2.   Physical model
  • In this paper, we show that UPB based on the quantum interference between different transition paths appears within a narrow range of parameters, and this feature can be applied to realize sensitive sensing. As a specific platform for UPB, we consider an MZI with two cavities (a1 and a2) in its two arms, as shown in Fig. 1(a), and discuss the second-order correlation of the output field in the next section. A probe field is divided into two beams by a 50/50 beam splitter (BS), and then injected into one of the cavities, respectively. The transmitted fields from the two cavities are mixed by another 50/50 BS, and a phase shifter (PS) is placed in one of the two arms to change the phase difference between them. The second-order correlation of the output field aout can be measured by a Hanbury–Brown–Twiss (HB-T) set-up. In the frame rotating at the probe laser frequency ωp, the system can be described by the Hamiltonian (ħ = 1)

    where ai and ai† are the annihilation and creation operators of the cavity mode i with resonance frequency ωi (i = 1,2), Δi = ωi–ωp is the detuning of the probe laser from the cavity resonance, δ = ω2–ω1 is the detuning between the two cavity modes, U is the nonlinear interaction strength in cavity mode 1, and εi=κiPin/(ħωp) is the driving strength on cavity mode i, with the driving power Pin and the decay rate from one of the cavity mirrors κi.

    The two fields aout and Aout output from the MZI can be obtained according to the input–output relation[105]

    where ϕ is the phase difference between the laser beams output from the two arms (which can be tuned by the PS), and avac, avac′ are the input vacuum fields. As the output field Aout can be obtained from aout just by replacing ϕ with ϕ + π, we will only focus on the output field aout in the following.

    Here, we focus on the quantum correlation of photons described by the second-order correlation function. The second-order correlation function of the output field aout from the MZI is given by

    where n = l + m – j – k, 2Nout=κ1〈a1†a1〉+κ2〈a2†a2〉+2κ1κ2Re(eiϕ〈a1†a2〉), and τ are the time delays between the two photodetectors (D1 and D2 in the HB-T set-up). There are cross-correlations between the photons in the two cavities (i.e., 〈a2†a1†a2a1〉, 〈a1†a1†a2a2〉, 〈a1†a1†a1a2〉, and 〈a2†a1†a2a2〉), and there are phase factors einϕ in front of the terms, which can be negative and lead to strong photon blockade in the weak nonlinear regime based on quantum interference.

    The system dynamics are governed by the master equation[106] for the density matrix ρ:

    In the following discussions, we set κ1 = κ as the unit of frequency. We consider a weak nonlinear interaction (U/κ = 0.02, unless specified otherwise) for two reasons: (i) achieving a strong Kerr nonlinearity in an optical resonator remains a great experimental challenge;[107] (ii) the second-order correlation function of the output field is more sensitive to the system parameters for a weaker nonlinear interaction strength (see Appendix A). To avoid the excitation of multiphoton states, the amplitude of the probe field is also kept weak (εi/κ = 0.1, unless specified otherwise) to achieve photon blockade.

3.   Photon blockade with weak nonlinearity
  • First of all, let us discuss how to realize photon blockade with weak nonlinearity in the MZI. The second-order correlation of the output field log10[gout(2)(0)] is plotted as a function of the phase ϕ/π and detuning δ/κ for a nonlinear strength of U/κ = 0.02 in Fig. 1(b) with κ1 = κ2 = κ. Strong photon anti-bunching gout(2)(0)≪1 is obtained around the parameters (δ ≈ −0.47κ, ϕ = 0.824π) and (δ ≈ 0.47κ, ϕ = 1.104π) with the weak nonlinearity (U = 0.02κ). In addition, the results for κ2 ≠ κ1 and different nonlinear strengths U are shown in the Appendix, which show two points: (i) κ2 ≠ κ1 mainly shifts the optimal detuning δ for photon blockade; (ii) gout(2)(0)<1 appears in a narrower parameter range for a weaker nonlinear interaction strength.

    The second-order correlation log10[gout(2)(0)] is also plotted as a function of the nonlinear interaction strength U/κ and detuning δ/κ for ϕ = 0.824π in Fig. 1(c). The minimal value of log10[gout(2)(0)] is obtained around U = 0.02κ. The second-order correlation gout(2)(τ) versus time delay τκ is shown in Fig. 1(d). Different from the rapid oscillations induced by the coupling between two cavities predicted in weakly nonlinear photonic molecules,[41,42] here there is no oscillation behavior as the delay time goes on, and the scale of the time delay is determined by the decay rate of the cavities as 1/κ.

    In order to understand the origin of the strong antibunching, we consider a non-Hermitian Hamiltonian including the decay effect as H′=H−iκ1a1†a1−iκ2a2†a2 and use the wave function terminated to the two-photon states as

    for weak probe fields εi ≪ {κ1,κ2}. Substituting the non-Hermitian Hamiltonian and wave function into the Schrödinger’s equation iħ∂∂t|ψ〉=H′|ψ〉, we get the dynamical equations for the probability coefficients as

    In the steady state, i.e., dCij/dt = 0, the linear equations for the probability coefficients are given by

    Under the weak driving conditions (εi ≪ {κ1,κ2}), we have C00≈1≫{|C10|,|C01|}≫{|C20|,|C02|,|C11|}. By setting Δ1 = 0 and ε1 = ε, we have Δ2 = δ and ε2=εκ2/κ1 for the same driving power on the two cavities. Thus, the expressions of the probability coefficients are given by

    for single-photon states, and by

    for two-photon states.

    Based on the probability coefficients, the output photon intensity Nout/κ and second-order correlation function gout(2)(0) can be expressed as

    The optimal conditions for photon blockade are obtained from

    and they are given by

    for the weak nonlinearity U ≪ κ1.

    To understand the conditions for photon blockade intuitively, the probability coefficients of two photons in the cavities (C20, C11, and C02) and in the output field (C20+eiϕ2C11+e2iϕC02) are shown in Fig 1(e), with the parameters (κ1 = κ2 = κ, δ ≈ −0.47κ, ϕ = 0.824π, U/κ = 0.02) for minimal of gout(0). In addition, when κ1 ≠ κ2 (see Appendix A), we find that δopt linearly depends on the decay rate κ2 of cavity mode 2, but ϕopt is independent of κ2, which agree well with Eqs. (24)–(26).

4.   Quantum sensing based on photon blockade
  • We know that both the output photon intensity Nout/κ and the second-order correlation function gout(2)(0) depend on system parameters such as the phase ϕ and the detuning δ, as shown in Fig. 2. From the figure, we can see that the phase interval Δϕ of the second-order correlation function from its minimum value gout(2)(0)=0.0044 (antibunching) to its maximum value gout(2)(0)=7.15 (bunching) is about Δϕ ≈ π/20, which is much narrower than the phase interval (Δϕ ≈ π) from the maximum to minimum value of the output photon intensity Nout/κ. The frequency interval Δω between the maximum value gout(2)(0)=1.91 (bunching) and the minimum value gout(2)(0)=0.0044 (antibunching) is about Δω ≈ 0.18κ, which is also much narrower than the frequency interval (Δω ≈ 2.4κ) from the maximum to minimum value of Nout/κ. That is, the second-order correlation function gout(2)(0) is much more sensitive to the parameters than the output photon intensity Nout/κ. This interesting effect can be understood by the fact that under the weak driving condition, the change of gout(2)(0) mainly originates from destructive interference among the three paths for two photons passing through the system [see Eq. (23)]; while the output photon intensity Nout/κ depends on the interference between the two paths for one photon passing through the system [see Eq. (22)]; in special parameter region, the interference among the three paths for two photons is much more sensitive to the parameters than the interference between the two paths for one photon. Such effect provides us the key mechanism for sensitive sensing based on the second-order correlation. As examples, here we will propose two schemes to realize angular velocity sensing and temperature sensing, respectively, by measuring the second-order correlation of the photons output from the MZI.

  • As a specific example, we consider the case in which the platform rotates with an angular velocity Ω as shown in Fig. 3(a), which leads to an additional phase difference Δϕ between the two beams as

    where A is the area enclosed by the optical paths, λ0 is the wavelength of the incident light, and c is the speed of light in vacuum. We set the phase difference ϕ0 = 0.85π for the platform to zero in the steady state, so we have the total phase difference ϕ = 0.85π + Δϕ for the system rotating with an angular velocity Ω. In the following numerical calculations, we take the parameters:[108] incident light with a wavelength of λ0 = 1550 nm, and two fiber coils with the same length L = 5 km and diameter D = 40 cm, i.e., the total effective area is A = (2 × L × D)/4 = 103 m2. The two optical cavities are formed between the two fiber-mirrors.[109]

    The output photon intensity Nout/κ and second-order correlation function gout(2)(0) are plotted as functions of the angular velocity Ω in Fig. 3(b). We can see that the second-order correlation function gout(2)(0) is much more sensitive to changes in the angular velocity Ω than the photon intensity Nout/κ. To characterize the sensitivity of Nout/κ and gout(2)(0) to changes in the angular velocity Ω, we can define the sensitivity coefficients as

    The sensitivities ηn,Ω and ηg,Ω are plotted as functions of the angular velocity Ω in Fig. 3(c). The maximal value of ηg,Ω is about four orders of magnitude greater than that of ηn,Ω. It is known that the rotational angular velocity of the Earth is about Ωearth = 7.3 × 10−5 rad/s, and we have gout(2)(0)=2.79 for Ω = 0 and gout(2)(0)=2.97 for Ω = Ωearth. We note that the detection of the second-order correlation of photons has been widely used to test the performance of single-photon sources,[110] and the standard deviation of the second-order correlation function smaller than 0.01 is within the reach of current technology.[111–113] Thus we can detect the rotation of the Earth by measuring the second-order correlation function gout(2)(0) of the photons output from the MZI.

  • In this subsection, we consider a dielectric layer in the cavity a2 as shown in Fig. 4(a), and discuss how to measure the change in temperature based on the thermal effect. Such a setup can be realized with a dielectric membrane placed between two macroscopic, rigid, high-finesse mirrors, which has been widely used to investigate the coupling between macroscopic mechanical resonators and the electromagnetic field through radiation pressure, also known as the “membrane-in-the-middle” optomechanical system.[114–117] Moreover, the Fabry–Pérot (FP) cavity can also be formed between the ends of two single-mode optical fibers with smooth concave depressions machined using a laser ablation technique, and the dielectric membrane can be held in a fixed mount attached to a piezoelectric scanner, providing linear motion along the axis of the FP cavity.[118–120] Due to thermal expansion, the thickness of the dielectric layer changes as

    where d0 is the thickness of the dielectric layer at a reference temperature, α is the thermal expansion coefficient, and ΔT is the temperature variation. In addition, because of the thermal-optical effect, the refractive index also depends on the temperature as

    where n0 is the refractive index at a reference temperature and β is the thermal-optic coefficient. Based on these two factors, the frequency shift of the cavity a2 is given approximately as

    where ω2 is the eigenfrequency of the cavity a2 at a reference temperature with a cavity length L. Under the condition that ω2 – ω1 = -0.56κ, we have the detuning δ = −0.56κ+δth. As a simple example, we consider the dielectric layer as a SiO2 layer, with the typical parameters:[121,122]α = 5.5 × 10−7 °C−1, and β = 1.0 × 10−5 °C−1, n0 = 1.45 at the reference temperature 25 °C, λ0 = 1550 nm, ω2 = 2πc/λ0, and ω2/κ = 107. The other parameters are d0 = 0.01 mm and L = 1 mm.

    The output photon intensity Nout/κ and second-order correlation function gout(2)(0) are plotted as functions of temperature variation ΔT in Fig. 4(b). We can see that the second-order correlation function gout(2)(0) is much more sensitive to the variation of the temperature ΔT than the output photon intensity Nout/κ. To characterize the sensitivity of Nout/κ and gout(2)(0) with respect to ΔT, we can define the sensitivity coefficients as

    The sensitivities ηn,T and ηg,T are plotted as functions of the temperature variation ΔT in Fig. 4(c). The maximal value of ηg,T is about 28 °C−1, which is 3 × 103 times greater than the maximal value of ηn,T.

5.   Conclusions
  • In this paper, we propose schemes to achieve sensitive sensing based on the UPB appearing in a narrow range of parameters. We demonstrate that UPB can be achieved in the mixed-field output from the two cavities, in the two arms of an MZI, even in the weak nonlinear regime. Based on the UPB, we propose schemes to realize angular velocity and temperature sensing by measuring the second-order correlation of the photons output from the MZI, and show that the second-order correlation of the photons is much more sensitive to the system parameters than the mean photon number. On the one hand, our work provides a new perspective for using UPB in practical sensing applications; on the other hand, we propose a possible strategy to realize sensitive sensing based on the quantum correlation properties of an optical field with a very weak driving strength. In this strategy, the measurement processes are realized by using single-photon detectors, rather than a spectrometer, which at least provides a supplementary solution to traditional sensing schemes. Finally, a number of potential limitations of the sensing schemes based on the second-order correlation need to be considered. First, the sensing region through the second-order correlation is much narrower than that of the photon intensity. Second, the angular velocity and temperature resolution is limited by the measuring instruments of the second-order correlation. These limitations, however, point to the following directions for future research.

Appendix A: Numerical results for different U and κ2
  • Here, we will investigate the effect of the nonlinear strength U and the difference between κ2 and κ1 on the second-order correlation. log10[gout(2)(0)] versus phase ϕ/π and detuning δ/κ for different U are shown in Figs. A1(a) and A1(b). Through comparison of the results for different U, i.e., Figs. 1(b), A1(a), and A1(b), we find that, besides the optimal detuning δ/κ and phase ϕ/π for photon blockade being different, gout(2)(0)<1 can be achieved in a wider region by a larger nonlinear strength, which is positive for realizing single-photon sources. However, gout(2)(0) is more sensitive to the parameters of the system for a weaker nonlinear interaction strength, which is more suitable for sensitive sensing.

    The second-order correlation log10[gout(2)(0)] for κ2 ≠ κ1 = κ is shown in Figs. A1(c) and A1(d). Specifically, the optimal detuning for photon blockade is δ/κ = −0.42 for κ2 = 0.9 κ1 [Fig. A1(c)], δ/κ = −0.47 for κ2 = κ1 [Fig. A1(b)], and δ/κ = −0.52 for κ2 = 1.1κ1 [Fig. A1(d)], which show that the optimal detuning for photon blockade linearly depends on the decay rate κ2. In contrast, the optimal phase for photon blockade is the same (ϕ/π = 0.824) for different κ2. These numerical results agree well with Eqs. (24)–(26). Moreover, there is no significant difference in the parameter range for gout(2)(0)<1 with |κ1–κ2| < 0.1κ1, which means that the main conclusions in the main text still work when a slight difference is present between the two decay rates.

Figure (5)  Reference (122)

Catalog

    /

    DownLoad:  Full-Size Img  PowerPoint
    Return
    Return