2026 Volume 35 Issue 9
Article Contents

Guang-Hua Xu, Shiyou Chen, Yue-Yang Liu. Asymmetric charge trapping and emission kinetics in SiO2/HfO2 for accurate transistor reliability simulation[J]. Chinese Physics B, 2026, 35(9): 097201. doi: 10.1088/1674-1056/ae7db4
Citation: Guang-Hua Xu, Shiyou Chen, Yue-Yang Liu. Asymmetric charge trapping and emission kinetics in SiO2/HfO2 for accurate transistor reliability simulation[J]. Chinese Physics B, 2026, 35(9): 097201. doi: 10.1088/1674-1056/ae7db4

Asymmetric charge trapping and emission kinetics in SiO2/HfO2 for accurate transistor reliability simulation

  • Received Date: 16/04/2026
    Accepted Date: 10/06/2026
    Available Online: 01/09/2026
通讯作者: 陈斌, bchen63@163.com
  • 1. 

    沈阳化工大学材料科学与工程学院 沈阳 110142

  1. 本站搜索
  2. 百度学术搜索
  3. 万方数据库搜索
  4. CNKI搜索

Figures(4)

Article Metrics

Article views(49) PDF downloads(0) Cited by(0)

Access History

Asymmetric charge trapping and emission kinetics in SiO2/HfO2 for accurate transistor reliability simulation

Abstract: Charge trapping in gate dielectrics governs reliability degradation in advanced transistors, and an essential mission is calculating the trapping rates of different defects accurately. Here, by high-throughput ab initio calculations, we demonstrate a significant asymmetric relaxation behavior of oxide defects during charge trapping and emission, and thus the predominantly assumed symmetric relaxation is invalid. Multiscale atomic-to-device simulations further reveal that the conventional symmetric approximation introduces orders-of-magnitude errors in charge transfer rates and qualitatively mischaracterizes the defect-resolved degradation. Therefore, we provide asymmetric relaxation data and corresponding modified charge trapping model for accurate reliability simulation of advanced transistors.

  • Charge trapping and emission are fundamental quantum-mechanical processes in semiconductor devices. On the one hand, charge trapping can be exploited as an operating mechanism in charge-trapping memories and reconfigurable devices.[1,2] On the other hand, charge trapping at defects in gate dielectrics is the microscopic origin of reliability degradation in metal–oxide–semiconductor field-effect transistors (MOSFETs), such as bias temperature instability (BTI),[3–6] random telegraph noise (RTN),[7–9] and dielectric breakdown (DB).[10–13] Therefore, charge trapping and emission kinetics must be accurately understood and controlled in different device contexts. Charge transfer theories, notably non-radiative multi-phonon (NMP) theory and Marcus theory, provide a robust physical framework for describing these processes.[14–17] Central to these theories is the configuration coordinate diagram (CCD),[18] in which activation barriers are determined by the crossing point of the initial and final state potential energy surfaces (PESs) relative to their respective minima. As illustrated in Fig. 1(a), the two PESs in the configuration-coordinate diagram have their own curvatures, which determine the relaxation energies for charge capture (λcap) and emission (λemi). Here, the curvature ratio is defined as R=λemi/λcap, which characterizes the asymmetry between the capture and emission PESs through their relaxation energies. The conventional symmetric approximation assumes identical PES curvatures,[19] forcing λemi = λcap and thus R = 1. Under this approximation, the capture and emission processes are described by symmetric parabolic PESs, so the crossing point and activation barriers can be obtained from the simplified symmetric expression in Fig. 1(c). This simplification has made the symmetric model the prevailing choice in reliability modeling.

    In reality, however, structural relaxation paths for charge capture and emission often differ due to changes in local bonding environments,[20–22] corresponding to the asymmetric model shown in Fig. 1(b), where λcap ≠ λemi. The barrier is then described in a more complex form as shown in Fig. 1(c). Despite this physical reality, the symmetric approximation continues to dominate reliability modeling, leaving the physically realistic asymmetric relaxation behavior largely overlooked. This raises a critical question: can the symmetric model faithfully reproduce the predictions of the rigorous asymmetric model? Answering this question requires first examining the relaxation energy data from atomistic calculations. Recent studies have indeed revealed relaxation energy asymmetry for SiO2 defects.[21,22] Yet whether similar asymmetry exists for defects in HfO2, the dominant high-k gate dielectric in scaled CMOS technologies,[23] remains largely unexplored. Furthermore, even where asymmetry has been identified, its quantitative impact on device-level reliability predictions has not been systematically evaluated.

    In this work, we address this question through a multiscale investigation combining high-throughput ab initio calculations, charge transfer theory, and compact physics simulations. We first quantify the relaxation energy asymmetry for typical defects in SiO2 and HfO2, filling a notable data gap for advanced gate stacks. Based on the ab initio defect fingerprints, we then calculate charge transfer rates using Marcus theory and assess the model influence on threshold voltage shifts using the multiscale ab initio reliability simulator (MARS).[24] The multiscale results demonstrate significant discrepancies between the symmetric and asymmetric models, underscoring the necessity of incorporating asymmetric relaxation kinetics for reliability modeling and optimization of advanced MOSFETs.

    The defect parameters were obtained via density functional theory (DFT) calculations using the PWmat software package[25] with a cutoff energy of 50 Ry. Amorphous SiO2 and HfO2 supercells, both containing 324 atoms, were used to model the dielectrics (see Fig. S1). The amorphous structures were generated by the bond switching Monte Carlo method.[26,27] Due to the large size of these supercells, the Brillouin zone was sampled at the single Gamma point. Structural optimizations were performed using the PBE functional[28] until the atomic forces converged to 0.01 eV/Å, and static calculations were carried out using the HSE hybrid functional[29] to ensure band gaps consistent with experimental values and gain suitable band alignment.[30] The investigated defects include oxygen vacancies (VO), hydrogen bridges (HB), and hydroxyl groups (OH) in SiO2, as well as VO, hydrogen-substituted oxygen complex (VO+Hi), and OH in HfO2. Since all atomistic sites in amorphous structures are non-equivalent, we systematically sampled at least 30 different sites for each defect type to ensure statistical significance.

    Figure 2 shows the statistical distributions of the calculated relaxation energies for hole capture (λcap, red) and emission (λemi, blue) for the six defect types. The results demonstrate that asymmetric relaxation energies are a general phenomenon rather than an exception. Specifically, SiO2-VO, SiO2-OH, HfO2-OH, and HfO2-VO+Hi exhibit significant asymmetry, characterized by a clear separation between the peak positions of the λcap and λemi distributions, as shown in Figs. 2(a)–2(d). In contrast, the distributions for SiO2-HB and HfO2-VO show overlapping distributions, indicating near-symmetric relaxation energy, as shown in Figs. 2(e) and 2(f).

    To investigate the kinetic impact of relaxation energy asymmetry, we first performed DFT calculations for the defect fingerprints, and then calculated the charge transfer rates using Marcus theory with the symmetric and asymmetric models (detailed formulas are given in the supplementary information S3). It should be noted that the defect parameters in amorphous dielectrics are not single values but distributions. Each point in the parameter distribution corresponds to a specific CCD, activation barrier, and charge-transfer rate. Therefore, using the full distributions would lead to a set of CCDs and rate curves. To clearly illustrate the basic physical picture, Fig. 3 compares three representative defects: SiO2-HB, HfO2-VO, and HfO2-VO+Hi, using CCDs constructed from the mean values of the parameter distributions summarized in Table S1. The electric field effect depends on the oxide electric field Fox and the defect position xt. In the rate calculation, this effect enters as the field-induced energy shift (q ⋅ Fox ⋅ xt), which shifts the defect level Et and changes the crossing points of the potential-energy surfaces and thus the capture barriers. The resulting barrier differences are directly reflected in the predicted capture rate (kcap) as a function of the field-induced energy shift, as shown in the bottom row.

    Strikingly, the symmetric approximation holds for SiO2-HB but fails for HfO2-VO, even though both defects appear similarly near-symmetric in their relaxation energies. For SiO2-HB, as shown in Fig. 3(a), the barrier difference between the symmetric and asymmetric models is only 0.02 eV at the unshifted case and shrinks to 0.005 eV after the field-induced shift, yielding nearly identical rate curves as shown in Fig. 3(d). By contrast, HfO2-VO, despite having a similar curvature ratio (R ∼ 0.87) to SiO2-HB, exhibits a much stronger field response. As shown in Fig. 3(b), the barrier difference increases from 0.03 eV to 0.28 eV with Et shifted, leading to a clear deviation in the high-field region. Consequently, the capture rates deviate in the high-field region, as shown in Fig. 3(e). Compared to SiO2-HB and HfO2-VO, the model discrepancy is even more pronounced for HfO2-VO+Hi, where the barrier difference increases from 0.48 eV to 1.52 eV (Fig. 3(c)) and the predicted rates differ by several orders of magnitude (Fig. 3(f)).

    This comparison reveals a critical finding that the validity of the symmetric approximation is governed not only by the curvature ratio R, but also by the absolute magnitudes of relaxation energies. Although SiO2-HB and HfO2-VO share similar R values, the former has much larger relaxation energies (λcap = 1.68 eV, λemi = 1.28 eV) and lower defect level (Et = −0.81 eV) than the latter (λcap = 0.81 eV, λemi = 0.61 eV, Et = 0.53 eV). Larger relaxation energies and lower defect level of SiO2-HB cause the parabolas to intersect at the flatter region, so the barrier difference between symmetric and asymmetric models remains small even after the shift in Et, as shown in Fig. 3(a). When relaxation energies are smaller, however, the barrier becomes more sensitive to the energy shift and the discrepancy between the two models is amplified under high-field conditions, as shown in Fig. 3(b). Thus, the symmetric model can fail even for defects with apparently near-symmetric relaxation energies. Similar discrepancies between the two models are also observed for other defects, as shown in Fig. S2.

    To evaluate the device-level impact of the model discrepancies, we further performed atomic-to-device NBTI simulations of a 28 nm commercial PMOS at 125 ° using the MARS simulator.[24] Whereas Fig. 3 uses mean defect parameters to illustrate the fundamental physical picture, Fig. 4 incorporates realistic defect distributions (Table S1) and compares the defect-resolved ΔVth predicted by the two models. Hole trapping was simulated under stress at Vg = −1.582 V, followed by recovery at Vg = −0.482 V, as shown in Fig. 4(a). In the calculations of the threshold voltage shift (ΔVth), the dielectric thickness was discretized into xt grid positions, and the contribution from each grid point was weighted according to Eq. (7) in supplementary information S5, with the defect-specific parameter distributions included.

    For SiO2-HB (Fig. 4(b)), the symmetric model underestimates ΔVth, even though the two models give nearly identical capture rates for the mean defect parameters (Fig. 3(d)). This originates from the distribution-integrated nature of device simulation, in which the mean parameters represent only one point in the xt, Et, λcap, λemi mesh array, whereas tail gridpoints in the full distribution can still contribute disproportionately. For these distribution-tail states, the asymmetric model predicts nearly complete occupation because emission becomes vanishingly small, while the symmetric model yields only moderate occupation. The resulting occupancy mismatch gives rise to an underestimated ΔVth in the symmetric model.

    HfO2-VO shows a similar trend to SiO2-HB, with the symmetric model underestimating the degradation (Fig. 4(c)). The discrepancy becomes qualitative for HfO2-VO+Hi (Fig. 4(d)). The asymmetric model predicts degradation that accumulates over repeated stress-recovery cycles and remains only weakly recoverable, whereas the symmetric model predicts nearly constant trapped charge and hence a negligible ΔVth. Thus, for this special defect type, the symmetric approximation does not merely underestimate the degradation. Instead, it misidentifies a partially permanent trapping behavior as essentially harmless. This failure arises from the extreme relaxation energy asymmetry of HfO2-VO+Hi, which causes the symmetric approximation to severely deviate from the rigorous asymmetric model in both capture and emission barriers, and consequently leads to a qualitatively incorrect device-level prediction. It should be noted that the corrections introduced by the asymmetric model are defect- and condition-dependent. Whether these corrections increase or decrease the capture/emission barriers, transition rates, and threshold-voltage shift should be analyzed for the specific defect parameters and bias conditions.

    In conclusion, our multiscale analysis demonstrates that asymmetric relaxation energies are an intrinsic feature of defects in both SiO2 and HfO2. The widely used symmetric approximation therefore neglects the asymmetric relaxation kinetics and can lead to orders-of-magnitude errors in rate predictions together with substantial misestimation of ΔVth. For defects with highly asymmetric relaxation energies, the symmetric model can even misidentify partially permanent degradation as recoverable and thus produce qualitatively incorrect device-level behavior. Crucially, our results further show that apparent relaxation energy symmetry does not guarantee the validity of the symmetric approximation, which has not been recognized previously. This study underscores that the asymmetry of potential energy surfaces is a critical missing link in conventional reliability frameworks. Although our direct first-principles calculations and device-level simulations are performed for defects in SiO2 and HfO2, the physical origin of asymmetric relaxation is not limited to these two kinds of dielectrics. In amorphous oxides, the structural complexity and defect-specific relaxation paths after charge-state transitions generally make the relaxation energies for carrier capture and emission different. Therefore, asymmetric relaxation energies should be regarded as a broadly relevant feature of defects in other amorphous dielectrics, such as ZrO2 and Al2O3. Ultimately, the paradigm shift from symmetric approximation to ab initio-informed asymmetric kinetics is essential for reliability modeling, understanding, and optimization of advanced semiconductor devices.