  • 摘要: 基于全光纤以及主控振荡功率放大器,设计并搭建了一套扫频范围为125~165 MHz的拍频信号的放大系统.并设计了一套基于1064 nm的Nd:YAG单块非平面环形腔激光器作为单频种子源.通过声光移频的方式将1064 nm单频激光分成中心频差为150 MHz的两束激光进行拍频.双频激光初始功率为50mW,通过放大系统将双频功率放大到10 W.通过实验及分析得出两束频差为150 MHz的激光功率比率在放大之后保持不变,且经过放大的激光信号中,拍频信号所占的功率成分可以通过调节双频功率比以及单臂分量的偏正态来获得最大输出.同时对拍频信号的信噪比及线宽进行了实验分析.
  • 加载中
  • 加载中
计量
  • 文章访问数:  350
  • HTML全文浏览数:  151
  • PDF下载数:  31
  • 施引文献:  0
出版历程
  • 刊出日期:  2014-12-30

高功率可调谐双频激光全光纤放大实验研究

  • 北京理工大学光电学院,北京,100081

摘要: 基于全光纤以及主控振荡功率放大器,设计并搭建了一套扫频范围为125~165 MHz的拍频信号的放大系统.并设计了一套基于1064 nm的Nd:YAG单块非平面环形腔激光器作为单频种子源.通过声光移频的方式将1064 nm单频激光分成中心频差为150 MHz的两束激光进行拍频.双频激光初始功率为50mW,通过放大系统将双频功率放大到10 W.通过实验及分析得出两束频差为150 MHz的激光功率比率在放大之后保持不变,且经过放大的激光信号中,拍频信号所占的功率成分可以通过调节双频功率比以及单臂分量的偏正态来获得最大输出.同时对拍频信号的信噪比及线宽进行了实验分析.