重频XeF蓝绿激光技术

上一篇

下一篇

于力, 马连英, 易爱平, 黄超, 朱峰, 安晓霞, 沈炎龙, 钱航, 黄欣, 黄珂, 叶锡生, 刘晶儒. 2011: 重频XeF蓝绿激光技术, 强激光与粒子束, 23(7): 1839-1842. doi: 10.3788/HPLPB20112307.1839
引用本文: 于力, 马连英, 易爱平, 黄超, 朱峰, 安晓霞, 沈炎龙, 钱航, 黄欣, 黄珂, 叶锡生, 刘晶儒. 2011: 重频XeF蓝绿激光技术, 强激光与粒子束, 23(7): 1839-1842. doi: 10.3788/HPLPB20112307.1839
Yu Li, Ma Lianying, Yi Aiping, Huang Chao, Zhu Feng, An Xiaoxia, Shen Yanlong, Qian Hang, Huang Xin, Huang Ke, Ye Xisheng, Liu Jingru. 2011: Technology of XeF blue-green laser with repetitive rate, High Power Lase and Particle Beams, 23(7): 1839-1842. doi: 10.3788/HPLPB20112307.1839
Citation: Yu Li, Ma Lianying, Yi Aiping, Huang Chao, Zhu Feng, An Xiaoxia, Shen Yanlong, Qian Hang, Huang Xin, Huang Ke, Ye Xisheng, Liu Jingru. 2011: Technology of XeF blue-green laser with repetitive rate, High Power Lase and Particle Beams, 23(7): 1839-1842. doi: 10.3788/HPLPB20112307.1839

重频XeF蓝绿激光技术

Technology of XeF blue-green laser with repetitive rate

  • 摘要: 利用表面放电光泵浦技术,研制了重频XeF(C-A)激光器,运行频率达到10 Hz.研究了运行频率、气体流量对激光输出能量稳定性的影响,分析了影响输出稳定性的主要因素,实验结果表明,提高气流量可有效改善重频输出能量的稳定性.同时,还给出了优化实验条件下不同运行频率连续20个脉冲较为理想的输出结果.运行频率分别为1,2,5 Hz时,输出能量稳定性较好,输出能量大于4.0 J;气流量大于53 L/s时,10Hz重频运行的输出稳定性已显著提高,平均输出能量也达到1.8J.
  • 加载中
  • 加载中
计量
  • 文章访问数:  421
  • HTML全文浏览数:  49
  • PDF下载数:  21
  • 施引文献:  0
出版历程
  • 刊出日期:  2011-07-30

重频XeF蓝绿激光技术

  • 西北核技术研究所激光与物质相互作用国家重点实验室,西安,710024

摘要: 利用表面放电光泵浦技术,研制了重频XeF(C-A)激光器,运行频率达到10 Hz.研究了运行频率、气体流量对激光输出能量稳定性的影响,分析了影响输出稳定性的主要因素,实验结果表明,提高气流量可有效改善重频输出能量的稳定性.同时,还给出了优化实验条件下不同运行频率连续20个脉冲较为理想的输出结果.运行频率分别为1,2,5 Hz时,输出能量稳定性较好,输出能量大于4.0 J;气流量大于53 L/s时,10Hz重频运行的输出稳定性已显著提高,平均输出能量也达到1.8J.

English Abstract

参考文献 (0)

目录

/

返回文章
返回