双重频率锁定的腔衰荡吸收光谱技术及信号处理?

上一篇

下一篇

贾梦源, 赵刚, 侯佳佳, 谭巍, 邱晓东, 马维光, 张雷, 董磊, 尹王保, 肖连团, 贾锁堂. 2016: 双重频率锁定的腔衰荡吸收光谱技术及信号处理?, 物理学报, 65(12): 128701. doi: 10.7498/aps.65.128701
引用本文: 贾梦源, 赵刚, 侯佳佳, 谭巍, 邱晓东, 马维光, 张雷, 董磊, 尹王保, 肖连团, 贾锁堂. 2016: 双重频率锁定的腔衰荡吸收光谱技术及信号处理?, 物理学报, 65(12): 128701. doi: 10.7498/aps.65.128701
Jia Meng Yuan, Zhao Gang, Hou Jia-Jia, Tan Wei, Qiu Xiao-Dong, Ma Wei-Guang, Zhang Lei, Dong Lei, Yin Wang-Bao, Xiao Lian-Tuan, Jia Suo-Tang. 2016: Research and data pro cessing of double lo cked cavity ringdown absorption sp ectroscopy, Acta Physica Sinica, 65(12): 128701. doi: 10.7498/aps.65.128701
Citation: Jia Meng Yuan, Zhao Gang, Hou Jia-Jia, Tan Wei, Qiu Xiao-Dong, Ma Wei-Guang, Zhang Lei, Dong Lei, Yin Wang-Bao, Xiao Lian-Tuan, Jia Suo-Tang. 2016: Research and data pro cessing of double lo cked cavity ringdown absorption sp ectroscopy, Acta Physica Sinica, 65(12): 128701. doi: 10.7498/aps.65.128701

双重频率锁定的腔衰荡吸收光谱技术及信号处理?

Research and data pro cessing of double lo cked cavity ringdown absorption sp ectroscopy

  • 摘要: 针对传统腔衰荡光谱技术浓度获取率低,提出基于双重锁定的连续波腔衰荡吸收光谱技术。通过波长调制一次谐波信号将激光器的频率锁定到C2H2吸收线上,同时使用PDH锁频技术将衰荡腔锁定到激光器上,从而避免了测量过程中激光器的频率漂移和腔长的抖动,使测量结果更加精确;并且,由于双重锁定,单次衰荡事件的发生率,也就是浓度信息的获取率只受衰荡时间以及重新锁定时间限制,在本试验系统中采集速率可以达到30 kHz,可以实现对气体浓度的快速测量。为了提高信噪比,采用Kalman滤波技术,对浓度信息进行实时处理,有效抑制了噪声,根据阿伦方差分析,探测灵敏度可以达到4×10?9 cm?1(2 s平均)。
  • 加载中
  • 加载中
计量
  • 文章访问数:  379
  • HTML全文浏览数:  84
  • PDF下载数:  0
  • 施引文献:  0
出版历程
  • 刊出日期:  2016-06-30

双重频率锁定的腔衰荡吸收光谱技术及信号处理?

  • 山西大学激光光谱研究所,量子光学与光量子器件国家重点实验室,太原 030006; 山西大学,极端光学协同创新中心,太原 030006

摘要: 针对传统腔衰荡光谱技术浓度获取率低,提出基于双重锁定的连续波腔衰荡吸收光谱技术。通过波长调制一次谐波信号将激光器的频率锁定到C2H2吸收线上,同时使用PDH锁频技术将衰荡腔锁定到激光器上,从而避免了测量过程中激光器的频率漂移和腔长的抖动,使测量结果更加精确;并且,由于双重锁定,单次衰荡事件的发生率,也就是浓度信息的获取率只受衰荡时间以及重新锁定时间限制,在本试验系统中采集速率可以达到30 kHz,可以实现对气体浓度的快速测量。为了提高信噪比,采用Kalman滤波技术,对浓度信息进行实时处理,有效抑制了噪声,根据阿伦方差分析,探测灵敏度可以达到4×10?9 cm?1(2 s平均)。