14 MeV中子照相中散射中子对成像影响的Monte Carlo模拟

上一篇

下一篇

章法强, 杨建伦, 李正宏, 应纯同, 刘广均. 2007: 14 MeV中子照相中散射中子对成像影响的Monte Carlo模拟, 物理学报, 56(6): 3577-3583. doi: 10.3321/j.issn:1000-3290.2007.06.089
引用本文: 章法强, 杨建伦, 李正宏, 应纯同, 刘广均. 2007: 14 MeV中子照相中散射中子对成像影响的Monte Carlo模拟, 物理学报, 56(6): 3577-3583. doi: 10.3321/j.issn:1000-3290.2007.06.089
Zhang Fa-Qiang, Yang Jian-Lun, Li Zheng-Hong, Ying Chun-Tong, Liu Guang-Jun. 2007: Monte Carlo simulation of effect of neutron scattering on image information in 14 MeV fast neutron radiography, Acta Physica Sinica, 56(6): 3577-3583. doi: 10.3321/j.issn:1000-3290.2007.06.089
Citation: Zhang Fa-Qiang, Yang Jian-Lun, Li Zheng-Hong, Ying Chun-Tong, Liu Guang-Jun. 2007: Monte Carlo simulation of effect of neutron scattering on image information in 14 MeV fast neutron radiography, Acta Physica Sinica, 56(6): 3577-3583. doi: 10.3321/j.issn:1000-3290.2007.06.089

14 MeV中子照相中散射中子对成像影响的Monte Carlo模拟

Monte Carlo simulation of effect of neutron scattering on image information in 14 MeV fast neutron radiography

  • 摘要: 依据实验参数,建立了14 MeV快中子照相的物理模型,并利用Monte Carlo方法对照相过程进行了模拟.分析了经聚乙烯样品散射的中子对快中子图像的影响随样品与探测器间距及样品参数的变化.计算结果表明,样品与探测器的距离d<5 cm时,样品中的散射中子对图像的影响强烈依赖于d,而当d>20 cm时,样品散射中子对图像的影响可忽略;当样品密度为3-5/cm3时散射中子对图像的影响相对最大;样品宽度越大,图像中的散射成分越多,当宽度在3 cm以上时散射成分的强度趋于饱和.
  • 加载中
  • 加载中
计量
  • 文章访问数:  425
  • HTML全文浏览数:  40
  • PDF下载数:  32
  • 施引文献:  0
出版历程

14 MeV中子照相中散射中子对成像影响的Monte Carlo模拟

  • 中国工程物理研究院核物理与化学研究所,绵阳,621900
  • 清华大学工程物理系,北京,100084

摘要: 依据实验参数,建立了14 MeV快中子照相的物理模型,并利用Monte Carlo方法对照相过程进行了模拟.分析了经聚乙烯样品散射的中子对快中子图像的影响随样品与探测器间距及样品参数的变化.计算结果表明,样品与探测器的距离d<5 cm时,样品中的散射中子对图像的影响强烈依赖于d,而当d>20 cm时,样品散射中子对图像的影响可忽略;当样品密度为3-5/cm3时散射中子对图像的影响相对最大;样品宽度越大,图像中的散射成分越多,当宽度在3 cm以上时散射成分的强度趋于饱和.

English Abstract

参考文献 (0)

目录

/

返回文章
返回